A fix is available
APAR status
Closed as program error.
Error description
After a successful TDMF migration using the default SPIDFENCE op tion, ICKDSF INIT of the old source volume failed with the messa ge ICK31306I VERIFICATION FAILED: DEVICE FOUND TO BE GROUPED
Local fix
Manually vary the device online and offline on the affected syst ems prior to running ICKDSF.
Problem summary
**************************************************************** * USERS AFFECTED: New ICKDSF parms now check for CU * * path groups being enabled/diasabled * * when a volume is being formatted or * * initialised after a TDMF migration. * * TDMF's use if the IEEVARYD service did not * * result in Logical Paths being disbanded. * **************************************************************** * PROBLEM DESCRIPTION: IEEVARYD when issued to a UCB with * * UCBONLI set off did not disband the * * logical paths. * **************************************************************** * RECOMMENDATION: * **************************************************************** TDMF will correct this and ensure the logical paths are withdrawn.
Problem conclusion
If the ICKDSF message is issued the operator VARY command can be used to disband the path groups.
Temporary fix
Comments
APAR Information
APAR number
OA49410
Reported component name
SOFTEK TDMF Z/O
Reported component ID
694932A00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-11-17
Closed date
2015-11-25
Last modified date
2015-12-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA79898 UA79899
Modules/Macros
GTDRTNV
Fix information
Fixed component name
SOFTEK TDMF Z/O
Fixed component ID
694932A00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"","label":""}}]