IBM Support

JR46785: CMVC 228406 - Issue a non-zero exit code on missing physical data conditions during StagingProp invocation

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During propagation of changed data by the StagingProp utility,
    primary keys pointed to by the STAGLOG table may not exist in
    the physical table whose data is to be propagated. This can
    occur due to a variety of reasons, e.g., primary key
    update.\line \line StagingProp marks the meta-data in the
    STAGLOG table for such records with an STGPROCESSED column value
     of -5 for diagnostic purposes.\line \line To further improve
    diagnosis, the utility will also issue a non-zero exit code,
    specifically exit-code 163, once it finishes execution to make
    users aware of such issue(s).
    

Local fix

  • Inspect the STAGLOG table on the staging database to see if any
    records exist with an STGPROCESSED column value of -5 after
    StagingProp has finished executing to see if any missing
    physical data conditions were encountered
    

Problem summary

  • USERS AFFECTED:
     WebSphere Commerce users on v7.0 who are prone to missing
    physical data (primary-key) conditions during StagingProp
    utility invocation
    
     PROBLEM ABSTRACT:
     Issue a non-zero exit code on missing physical data conditions
    during StagingProp invocation
    
     BUSINESS IMPACT:
     Customers may not be able to readily identify whether any
    missing physical data conditions were encountered during
    invocation of the StagingProp utility
    
     RECOMMENDATION:
     Inspect the STAGLOG table on the staging database to see if any
    records exist with an STGPROCESSED column value of -5 after
    StagingProp has finished executing to see if any missing
    physical data conditions were encountered
    

Problem conclusion

  • y physical data missing conditions were encountered, the
    StagingProp utility records an indicator to exit with a special
    exit-code if no other more severe, but tolerable errors were
    encountered. Upon completion, if this indicator is set, the
    exit-code is issued.
     -------------------------------------------------------------
     The latest available maintenance information can be obtained
    from the Recommended Fixes for WebSphere Commerce technote:
     http://www.ibm.com/support/docview.wss?rs=3046&uid=swg21261296
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR46785

  • Reported component name

    WC BUS EDITION

  • Reported component ID

    5724I3800

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / Serviceability

  • Submitted date

    2013-05-30

  • Closed date

    2013-06-06

  • Last modified date

    2013-06-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS EDITION

  • Fixed component ID

    5724I3800

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
06 June 2013