JR46439: ODBC CONNECTOR EXECUTING AFTER SQL STATEMENTS EVEN WHEN THE JOB ABORTS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In the ODBC connector, if a job is configured with some SQL
    statements in the After SQL property, these statements are
    executed even in the case where the job failed when any of the
    player processes failed. Ideally, when the main SQL statement
    generates any failure and the job has to abort, there is no
    reason why the After SQL statements should be executed.
    

Local fix

  • N/A
    

Problem summary

  • In the ODBC connector, if a job is configured with some SQL
    statements in the After SQL property, these statements are
    executed even in the case where the job failed when any of the
    player processes failed. Ideally, when the main SQL statement
    generates any failure and the job has to abort, there is no
    reason why the After SQL statements should be executed.
    

Problem conclusion

  • Do not execute After SQL statements when the job is failing.
    This change has been made under the scope of an environment
    variable CC_ODBC_SKIP_AFTERSQL_ON_FAILURE to insure that there
    is no change in behavior for any of the jobs designed this
    behavior of executing After SQL on job failure
    
    The environment variable (CC_ODBC_SKIP_AFTERSQL_ON_FAILURE)
    needs to be set to 1 in the job / project environment
    

Temporary fix

  • There is no known temporary fix
    

Comments

APAR Information

  • APAR number

    JR46439

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    870

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-24

  • Closed date

    2013-05-10

  • Last modified date

    2013-05-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R850 PSY

       UP

  • R870 PSY

       UP

  • R910 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 October 2021