IBM Support

IV83666: IE11 HANGS WHEN CONTINUALLY SWITCHING BETWEEN RTE FIELDS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The problem :IE11 hangs when continually switching between RTE
    Fields with mouse on same browser.
    Env : Maximo 7603 + ICD7601
    Recreation Scenario:
    1. Open the screen that has multiple rich text fields by IE11.
    ex) Open the application designer, open WOTRACK.  add 2
    RichText Editor
    control for 2 attributes.
    ex) description_longdescription,  remarkdesc_longdescription
    2. When clicking the multiple rich text fields alternately and
    conditnually using mouse, IE is hung..
       ( At this time, the CPU usage of iexplore.exe is keeping
    moving
       around 25% )
    FYI :old APAR IV55662 is related
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Internet Explorer only                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * IE11 HANGS WHEN CONTINUALLY SWITCHING BETWEEN RTE FIELDS     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Fixed in Tpae 7.6.0.6 fix pack.                              *
    ****************************************************************
    

Problem conclusion

  • Added check for "trident" to identify the IE browser, since
    has("ie") is not supported in IE 11.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV83666

  • Reported component name

    MAXIMO SYSTEMS

  • Reported component ID

    5724R46AV

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-04-12

  • Closed date

    2016-06-24

  • Last modified date

    2016-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO SYSTEMS

  • Fixed component ID

    5724R46AV

Applicable component levels

  • R760 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHPP5","label":"System Related"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 June 2016