Error description

  • When you duplicate a datasheet that has the Organization and
    Site values set but you change BOTH the Organization AND Site
    values on the duplicated record before saving, after save if you
    query the database the ORGID still holds the value from the
    original record.
    
    Pre-requisite
    log in as user WILSON
    Go to Profile DEFAULT Information
    Default Insert Site=BEDFORD
    
    Steps to Replicate
    Log into maximo
    Go to Dataheet Template application and insert New Record
    Organization=EAGLENA, Site=BEDFORD
    Scroll down to Asset Functions data area, click New Row
    Asset Function=1, Type=DISCRETE
    Go to sub-tab Calibration Points, click New Row
    Calibration Point=1, Description= Peak 1
    Save Record
    Go to More Actions: Duplicate Data Sheet
    Data Sheet=NEWNAME, Organization=EAGLESA, Site=CONCSITE
    NOTE: MUST change the Organization value from the value in
    original record
    Save record
    Connect to the database use a query tool
    run the following SLQ
    
    select * from PLUSCDSINSTR where DSPLANNUM='NEWNAME'
    
    Result: The ORGID is EAGLENA which is wrong, SITEID is CORRECT
    
    Expected Result: ORGID should be EAGLESA
    
    
    Application:
    Data sheet template
    
    Industry Solution:
    Calibration
    
    
    REPORTED IN VERSION:
    
    Tivoli's process automation engine 7.6.0.6 Build 20161019-0100
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * INCORRECT PLUSCDSINSTR TABLE ORG VALUE WHEN YOU DUPLICATE A  *
    * DATA SHEET AND CHANGE ORGID VALUE FROM ORIGINAL DATA SHEET   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package:
    		 | Release 7.6.1.2 of Base Services
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ17946

  • Reported component name

    MAXIMO CALIBRAT

  • Reported component ID

    5724R5700

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-07-30

  • Closed date

    2019-08-28

  • Last modified date

    2019-08-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO CALIBRAT

  • Fixed component ID

    5724R5700

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKZS","label":"Maximo Calibration"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
15 November 2022