IBM Support

IJ05195: GA-RF: LOCATION NAMES WITH UNDERSCORE CHARACTERS IN THEM PREVENT ASSIGNMENTS FROM BEING MADE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In the Graphical Assignment - Repair Facilities (GA-RF)
    application if the Location names have underscore characters in
    them, it prevents assignments from being made.
    
    Reproduced in 7.6.0.8 and 7.6.0.9
    
    To enable repair facilities you must first go to the
    Organizations application and go to the "Work Order Options"
    from the "Select Action" menu. From there, select "Other
    Organization Options".
    Once the options are displayed, check the "Enable Repair
    Facilities?" check box to enable this option. In addition you
    may also want to check the "Bypass Site Mismatch Warning
    Message?" depending on whether or not you want to allow a
    warning to be displayed if the location is not within your
    current site.
    
    After enabling repair facilities to be used, you can go to the
    Locations application and create a repair facility by setting
    the type to REPAIR.
    In addition you'll need to check the "Is a Repair Facility?"
    check box.
    
    If you use an environment that has the 761 Hangar Location data
    in it you can just enter a new Location as specified below.
    
    1. Create new Location with underscore ( _ ) in its name such as
    TEST_LOC.    Set the Type to OPERATING.
    Check the Is a Repair Facility? checkbox.
    2. Set its parent as 761HANGAR1.
    3. Give it Calendar DAY and Shift COMP1 as those are used on
    the GA-RF Work List 761_RF_DEMO.
    4. Go to GA-RF and use 761_RF_DEMO.
    5. Refresh the Work List so it sees the new Location.
    6. Click on the Assignment View tab
    7. Your new Location with the Underscrore should now be listed
    in the 761HANGAR1 hierarchy.
    8. Drag one of the requrements down to the new location's row.
    
    CURRENT ERRONEOUS RESULT:
    
    It will turn green but when you save, it will go back up to the
    unassigned section instead of staying on the Location row where
    it should stay.
    When you look  at the Assignment tab for the Work Order in
    WOTrack the Location Assignment will be blank.
    
    EXPECTED RESULT:
    
    The green bar should stay on the Location row where you placed
    it.
    The Location Assignment on the Assignment tab in WOTrack should
    be populated with the Location name and date/time and its
    status should be Assigned.
    

Local fix

  • (none)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the Graphical Assignment Repair Facility            *
    * application in Scheduler 7.6.5.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * LOCATION NAMES WITH UNDERSCORE CHARACTERS IN THEM PREVENT    *
    * ASSIGNMENTS FROM BEING MADE.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A code fix has been delivered to the stream.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ05195

  • Reported component name

    MAXIMO SCHEDULE

  • Reported component ID

    5724R46SE

  • Reported release

    765

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-23

  • Closed date

    2018-03-26

  • Last modified date

    2018-03-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO SCHEDULE

  • Fixed component ID

    5724R46SE

Applicable component levels

  • R765 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9NUN","label":"Maximo Asset Management Scheduler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"765","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
26 March 2018