Abstract
LIC-UNPRED SRCB6005121 SECOND ENDPEX TO COLLECTION
Error Description
ENDPEX was issued in a 5250 session on job #1, this job ended
abnormally due to a communication / device error. A second 5250
session, job #2, issued the same ENDPEX command and caused the
machine to terminate with SRCB6005121 SRC0002000A SRC00600001.
PERFtools
Problem Summary
****************************************************************
* PROBLEM: (MA38741) Licensed Program = 5722999 for i 5.4 *
* and i 5.4.5 *
* 5761999 for i 6.1 *
* and i 6.1.1 *
* Crash/Hang Requiring an IPL to Recover *
* SRC B600 5121 *
****************************************************************
* USERS AFFECTED: All IBM i operating system users for i 5.4, *
* i 5.4.5, i 6.1 and i 6.1.1. *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF48680 for i 5.4. *
* Apply LIC PTF MF48693 for i 5.4.5. *
* Apply LIC PTF MF48535 for i 6.1. *
* Apply LIC PTF MF48694 for i 6.1.1. *
****************************************************************
Interrupting the ENDPEX command for any reason can cause
unpredictable results including the possiblity of partition
crash if ENDPEX is later issued to the same PEX collection in a
different job.
Problem Conclusion
LIC support for the ENDPEX command is changed to avoid
unpredictable results.
Temporary Fix
*********
* HIPER *
*********
Comments
B6005121
0002000A
00600001
Circumvention
Run the ENDPEX command in batch to minimize the possiblity of
interruption.
PTFs Available
R540 MF48680 0117
R545 MF48693 0117
R610 MF48535 0215
R710 MF48695 0096
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | Yes |
Component.................................. | 9400DG300 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R610 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information
Document Information
Modified date:
17 August 2010