IBM Support

PH23578: WITH CUSTOM. PARM ENABLE_COPY_TABLE_STATISTICS SET TO TRUE A RELOAD OF A TABLE MAY RESULT IN A RESTART OF THE ACCELERATOR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • With customization parameter ENABLE_COPY_TABLE_STATISTICS set to
    true a reload of a table may result in a restart in a restart of
    the accelerator. This is especially true to reload of large
    tables with many columns (more than 260). During the processing
    Db2Wh generates a RUNSTATS command which becomes very long
    (larger than 32K Bytes) for such large tables.
    This causes an IDAA server stack overflow. The reload will fail
    immediately and the accelerator server will restart.
    

Local fix

Problem summary

  • The issue descibed was fixed in the IDAA V7 accelerator server.
    The fix became part of IDAA V7 maintenance level 7.5.1 made
    available on April 22,2020.
    

Problem conclusion

  • Upgrade your IDAA V7 maintenance level to 7.5.1 or higher.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH23578

  • Reported component name

    ANYTCS ACCLTR Z

  • Reported component ID

    5697DA700

  • Reported release

    750

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-23

  • Closed date

    2020-05-28

  • Last modified date

    2020-05-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
29 May 2020