IBM Support

IV36691: POWERHA:CLXD_VERIFY_GENXD FAILS WHEN MULTIPLE XIV STORAGE AGENTS

A fix is available

 

APAR status

  • Closed as program error.

Error description

  • The cluster was initially configured to support two XIV
    storage systems as an XD solution for remote inter-site
    replication using XD mirror groups between the sites.
    The cluster cannot be started up because the cluster
    verification & synchronization fails with errors reported
    by the clxd_verify_genxd script.
    The errors similar to given below can be found
    in the clverify.log file:
    ---------------------------------------------------------
    == ERROR >>
    Mirror Mode 'Error:' of consistency group 'TESTCI'
    differs from mirror mode 'async' of mirror group
    'ci_main_grp'.
    
    
    == INFO >> Initiating Verification for Mirror Group
    'ci_main_grp'. This can take several minutes.
    
    == INFO >> To check the progress of verification,
    '/var/hacmp/xd/verify/ver_ci_main_grp.out' file can be
    viewed.
    
    ERROR : --> End of data received before reading all the
    bytes. This may indicate that the 'clxd' daemon
    terminated abnormally. Expected to read '524' bytes.
    Total bytes read = '0'.
    ERROR : --> Failed to receive response for XD request
    from sock=19
    ERROR : --> Failed to send the request to XD daemon.
    ERROR : --> Failed to send a request to XD process. <TBD>
    == ERROR >>
    Failed to run verification on Mirror Group 'ci_main_grp'.
    
    == ERROR >>
    Failed to get the list of Mirror Groups. ERROR : -->
    Failed to connect() to XD process. sock=19 rc=-1 errno=79
    ERROR : --> Run 'lssrc -s clxd' command to see if 'clxd'
    daemon is running.
    ERROR : --> Failed to connect to the XD process. <TBD -
    More message to help the user>.
    
    == INFO >>
    Verification for DS8000(GM)/XIV completed.
    Error Count='3' Warning Count='1'.
    
            FAIL
    
    ERROR: User-defined XD verification utility
    /usr/es/sbin/cluster/xd_generic/xd_cli/clxd_verify_genxd
    failed.
    ---------------------------------------------------------
    The problem occurs when more than one storage agent is
    defined for a single XIV storage system. Another symptom
    may be the clxd_main daemon failed and core dumped.
    

Local fix

  • There is a work-around to not use more than one storage
    agent defined per a single XIV storage system.
    

Problem summary

  • Customer faced misleading errors.
    

Problem conclusion

  • Validation on number of agents for a storage server with proper
    messages.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV36691

  • Reported component name

    POWERHA 6.1 XD

  • Reported component ID

    5765H2310

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-02-13

  • Closed date

    2013-03-31

  • Last modified date

    2013-05-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA 6.1 XD

  • Fixed component ID

    5765H2310

Applicable component levels

  • R610 PSY U855582

       UP13/05/21 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]