Saving or cancelling changes on panel ERB3RDF

Once you have created or modified a report using the report format definition utility panels, RMF™ displays panel ERB3RDF, which allows you to confirm or cancel your changes.

Figure 1. Configuration/Cancellation Panel (ERB3RDF)
ERB3RDF                 RMF Report Format Definition
Command ===>


This is a confirmation/cancellation panel for report: SYSCPU
                               related with WLM mode: GOAL



The following actions are allowed:


       Type  SAVE   command to save report

       Type  CANCEL command to cancel processing

       Press END    key to go one step backwards

       Press ENTER  key to see the sample report

You can get a report with sample data just to verify the correct layout of the report. In this example, some values are not displayed because they are not part of the sample data.

Figure 2. Initial Version of the SYSCPU Report
ERB4CPU                 RMF V2R2  CPU Information                Line 1 of 20
Command ===>                                                  Scroll ===> PAGE

Samples:     60  System: SYSE  Date: 06/08/2016  Time: 08.59.00  Range:     60Sec

Partition:    SYSE    2084  Model 314         Appl% :     22  Policy: STANDARD
CPs Online:   4.0     Avg CPU Util%:   24     EAppl%:     22  Date:   05/12/05
AAPs Online:  1.0     Avg MVS Util%:   26     Appl% AAP:  19  Time:   12.20.27
IIPs Online:    -                             Appl% IIP:   -

Group     T WFL --Users--  RESP TRANS  CPU   TCB   SRB  -AVG USG-   -Avg Del-
             %   TOT  ACT  Time  /SEC   %     %     %   PROC  DEV   PROC  DEV

*SYSTEM      98  167    2        0.12  21.6  21.5   0.2  1.6  0.1    0.0  0.0
*TSO               3    0        0.12   0.0   0.0   0.0  0.0  0.0    0.0  0.0
*BATCH       99    3    2        0.00  20.5  20.5   0.0  1.5  0.0    0.0  0.0
*STC         91  158    0        0.00   1.2   1.0   0.2  0.1  0.1    0.0  0.0
*ASCH              0    0        0.00   0.0   0.0   0.0  0.0  0.0    0.0  0.0
*OMVS              3    0        0.00   0.0   0.0   0.0  0.0  0.0    0.0  0.0
*ENCLAVE           0  N/A         N/A   N/A   N/A   N/A  0.0  N/A    0.0  N/A
BATCH     W  99    4    2  .000  0.00  20.5  20.5   0.0  1.5  0.0    0.0  0.0
BATCHLOW  S  99    3    2  .000  0.00  20.5  20.5   0.0  1.5  0.0    0.0  0.0
OMVSKERN  S        1    0  .000  0.00   0.0   0.0   0.0  0.0  0.0    0.0  0.0
OMVS      W        2    0  .000  0.00   0.0   0.0   0.0  0.0  0.0    0.0  0.0
OE        S        2    0  .000  0.00   0.0   0.0   0.0  0.0  0.0    0.0  0.0
STC       W 100   26    0  .000  0.00   0.1   0.1   0.0  0.0  0.0    0.0  0.0
STCDEF    S 100   26    0  .000  0.00   0.1   0.1   0.0  0.0  0.0    0.0  0.0
SYSTEM    W  90  132    0  .000  0.00   1.0   0.9   0.2  0.1  0.1    0.0  0.0
SYSSTC    S 100  111    0  .000  0.00   0.3   0.3   0.0  0.0  0.0    0.0  0.0
SYSTEM    S  88   21    0  .000  0.00   0.7   0.6   0.2  0.1  0.1    0.0  0.0
TSO       W        3    0  .010  0.17   0.0   0.0   0.0  0.0  0.0    0.0  0.0
TSODEF    S        3    0  .010  0.17   0.0   0.0   0.0  0.0  0.0    0.0  0.0
BCP       R  99    3    2  .000  0.00  20.5  20.5   0.0  1.5  0.0    0.0  0.0

The report shows that adjustments for some columns are necessary. You can do this either by stepping back to panel ERB3RD8 before you save the report or by modifying the stored report.

Enter SAVE to save the report or CANCEL to cancel your changes and return to the report definition initialization panel (ERB3RD1). If you save the report, RMF redisplays panel ERB3RD1 with a message that tells you the report has been modified or created. To exit the sample report panel and return to panel ERB3RDF, press END.