Preparing to install a PCIe adapter in the system backplane

Complete the steps in this procedure to prepare to install a PCIe adapter in the system backplane

Procedure

  1. Complete the prerequisite tasks. For instructions, see Before you begin.
  2. Identify the part and the system that you will be working on. For instructions, see Identifying a part.
  3. If applicable, open the rack front door.
  4. Attach the electrostatic discharge (ESD) wrist strap.
    Attention:
    • Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware.
    • When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is used for static control. It does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment.
    • If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging and installing or replacing hardware, touch an unpainted metal surface of the system for a minimum of 5 seconds.
  5. Remove the front cover. For instructions, see Removing the front cover.
    (L007)
    CAUTION:
    A hot surface nearby. (L007)
  6. Stop the system. For instructions, see Stopping a system.
  7. If applicable, open the rack door at the rear of the system.
  8. Disconnect the power source from the system by unplugging the system. For instructions, see Disconnecting the power cords.
    Note: The system might be equipped with redundant power supply. Before you continue with this procedure, ensure that all power to your system is disconnected.
    (L003)
    Hazardous voltage or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label.
    or
    Hazardous voltage or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label.
    or
    Hazardous voltage or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label.
    or
    Hazardous voltage or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label.
    or
    Hazardous voltage or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label.
    DANGER
    Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003)
  9. Remove the two power supplies from the system. For instructions, see Removing the power supplies.
  10. Place the system into the service position. For instructions, see Placing the system into the service position.
    CAUTION:
    Do not place any object on top of a rack-mounted device unless that rack-mounted device is intended for use as a shelf. (R008)
    (L012)
    Pinch hazard
    CAUTION:
    Pinch hazard. (L012)
  11. Remove the service access cover. For instructions, see Removing the service access cover.