Use this MAP to resolve the following problem: Cache
data exists for one or more missing or failed disks (SRN nnnn-9051)
for PCIe2 or PCIe3 controllers.
The possible
causes follow:
- One or more disks have failed on the adapter.
- One or more disks were either moved concurrently or were removed
after an abnormal power off.
- The adapter was moved from a different system or a different location
on this system after an abnormal power off.
- The cache of the adapter was not cleared before it was shipped
to the customer.
Step 3232-1
Identify the affected disks
by examining the hardware error log. The hardware error log can be
viewed as follows:
- Follow the steps in Examining the hardware error log and return here.
- Select the hardware error log to view. Viewing the hardware error
log, the Device Errors Detected field indicates the total number
of disks which are affected. The Device Errors Logged field
indicates the number of disks for that detailed information is provided.
Under the Original Device heading, the Vendor/Product ID, S/N,
and World Wide ID fields are provided for up to three disks.
Additionally, the Original Controller Type, S/N, and World
Wide ID fields for each of these disks indicate the adapter to
which the disk was last attached when it was operational. See SAS resource locations to understand
how to locate a disk by using the Resources field.
- Go to Step 3232-2.
Step 3232-2
Are there other
disk or adapter errors that have occurred at approximately the same
time as this error?
- No
- Go to Step 3232-3.
- Yes
- Go to Step 3232-6.
Step 3232-3
Is the data
on the disks (and thus the cache data for the disks) needed for this
or any other system?
- No
- Go to Step 3232-7.
- Yes
- Go to Step 3232-4.
Step 3232-4
Have the adapter
card or disks been physically moved recently?
- No
- Contact your hardware service provider.
- Yes
- Go to Step 3232-5.
Step 3232-5
The adapter
and disks must be reunited so that the cache data can be written to
the disks.
Restore the adapter and disks back to their original
configuration.
After the cache data is written to the disks
and the system is powered off normally, the adapter or disks can be
moved to another location.
When the problem is resolved, see the removal and replacement
procedures topic for the system unit on which you are working and
do the "Verifying the repair" procedure.
Step 3232-6
Take action
on the other errors that have occurred at the same time as this error.
When the problem is resolved, see the removal and replacement
procedures topic for the system unit on which you are working and
do the "Verifying the repair" procedure.
Step 3232-7
Reclaim the
Controller Cache Storage by performing the following steps:
Attention: Data will be lost.
- Start the IBM® SAS Disk Array Manager.
- Start AIX Diagnostics and
select Task Selection on the Function Selection
display.
- Select .
- Select .
- Confirm that you will allow unknown data loss.
- Confirm that you wish to proceed.
When the problem is resolved, see the removal and replacement
procedures topic for the system unit on which you are working and
do the "Verifying the repair" procedure.