Dual-purpose resource definition for transient data
You cannot specify TYPE=REMOTE for transient data queues.
Instead, you may want to consider dual-purpose resource definition (see Shared resources for intercommunication). Dual-purpose resource definition can be used with transient data definitions. Figure 1 gives an example of dual-purpose resource definition for transient data resources.
If the definition shown in Figure 1 is installed in a system called CICQ, that definition becomes a local intrapartition queue (the value of REMOTESYSTEM is CICQ).
If the definition shown in Figure 1 is
installed in a system other than CICQ, the definition becomes a REMOTE
queue. Figure 1. Dual-purpose resource definition for
transient data
TDqueue : TDQ1
Group : Example
DEscription ==>
TYPE ==> Intra Extra | INTra | INDirect
EXTRA PARTITION PARAMETERS
DAtabuffers : 1-255
DDname :
DSname :
Sysoutclass :
Erroroption : Ignore | Skip
Opentime : Initial | Deferred
REWind : Leave | Reread
TYPEFile : Input | Output | Rdback
RECORDSize : 0-32767
BLOCKSize : 0-32767
RECORDFormat : Fixed | Variable
BLOCKFormat : Blocked | Unblocked
Printcontrol : A | M
DIsposition : Shr | Old |Mod
INTRA PARTITION PARAMETERS
Atifacility ==> Terminal Terminal | File | System
RECOVstatus ==> Logical No | Physical | Logical
Facilityid ==> FR1
TRAnsid ==>
TRIggerlevel ==> 00001 0-32767
Userid ==>
INDOUBT ATTRIBUTES
WAIT ==> Yes Yes|No
WAITAction ==> Reject Queue|Reject
INDIRECT PARAMETERS
Indirectname :
REMOTE PARAMETERS
REMOTEName ==> FR1
REMOTESystem ==> CICQ
REMOTELength ==> 0-32767