AAOI
Explanation
The journaling of data received on a CPI Communications mapped conversation has failed.
System action
The transaction is abnormally terminated with a CICS transaction dump.
User response
This condition is caused by an invalid response from the log manager. Use the dump to ascertain why the journal or log record could not be written correctly. If a journal record length error is indicated, TIOATDL may have been corrupted.
Problem determination
Register 12 addresses the current TCA and field TCAJCAAD and register 4 address the JCA. The CICS log manager request is contained in JCATR2 and the response code is in JCAJCRC.
Possible request codes are:
X'8001' - WRITE
X'8003' - PUT
Possible response codes are:
X'01' - IDERROR - Journal identification error
X'02' - INVREQ - Invalid request
X'03' - STATERR - Status error
X'05' - NOTOPEN - Journal not open
X'06' - LERROR - Journal record length error
X'07' - IOERROR - I/O error
The address of the TIOA is contained in register 8 and its data length is in TIOATDL.
Analysis:
Register Label Description
R4=@JCA TCZARQPJ JCAJCRC is nonzero.