AWBE

Explanation

The CICS Web Interface detected that a Converter program attempted to change the address of the response buffer when it was not allowed to do so.

System action

The data in the new response buffer is not returned to the Web browser. A CICS transaction dump is taken.

User response

The Converter program is only allowed to replace the response buffer if the converter_volatile flag in the Converter parameter list is set to '1'. Check that your Converter program is not trying to return a new response buffer when this flag is set to '0'.

Module

DFHWBBLI