IOADPTR
The failing component is the adapter in the location specified in the SRC.
- Are you working from the serviceable event view and is there a
card location listed with this FRU?
- Yes: Use Table 1 to replace the adapter identified by this location code. This ends the procedure.
- No: Determine the location of the adapter by working with the customer or your next level of support. If you cannot determine the location of the failing adapter by using SRC or resource information or the device tree, determine the adapter type from the SRC, SRC description, failing resources, or error message you are working with. Make a list of all the adapter locations of that type assigned to the partition. Continue with the next step.
- Have you identified a single FRU location?
- Yes: Use Table 1 to replace the FRU you have identified. This ends the procedure.
- No: Continue with the next step.
- Using the location codes you have
identified, determine which system unit and expansion units have PCI
adapters of this type assigned to the partition you are working with.
Starting with the expansion units first, remove all of the PCI adapters
of this type from one of the units (use Table 1 to guide you
to the correct locations information).Attention:Continue with the next step.
- Remove the PCI adapters from the system unit only after you have tried all of the expansion units first.
- Do not remove any FRUs with embedded adapters, only FRUs in PCI card slots.
- Reinstall one of the adapters and power on the unit. Continue with the next step.
- Does the problem recur?
- Yes: The adapter you just reinstalled is the failing item and needs to be replaced (use Table 1 to guide you to the correct locations information). This ends the procedure.
- No: Continue with the next step.
- Have you reinstalled all of the adapters on the unit you're currently
working with?
- Yes: Continue with the next step.
- No: Return to step 4 and reinstall the next adapter on this unit.
- Are there any units (including the system unit) on which you have
not yet removed and reinstalled the PCI adapters?
- No: Continue with the next step.
- Yes: Return to step 3 and work with another unit.
- See Card positions to determine
whether the system unit or any of the expansion units have an embedded
adapter of the type you are working with. Is there such an embedded
adapter?
- No: The problem might be intermittent. Contact your next level of support. This ends the procedure.
- Yes: The FRU with the embedded adapter is the failing item and needs to be replaced. Use Table 1 to replace the FRU at the location specified in the card position table. Repeat this step for each expansion unit with an embedded adapter assigned to the partition, and then for the system unit. This ends the procedure.
| FRU name (replace FRUs in order, one at a time, starting with the primary unit and then the secondary units if applicable) | Type and model | Location |
|---|---|---|
| PCIe embedded USB controller | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1 |
| PCIe3 x8 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C2 |
| PCIe3 x16 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C3 |
| PCIe3 x16 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C5 |
| PCIe3 x16 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C6 |
| PCIe3 x16 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C7 |
| PCIe3 x8 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C9 |
| PCIe3 x8 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C10 |
| PCIe3 x8 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C11 |
| PCIe3 x8 IOA card | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C12 |
| PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C14 |
| PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A | Un-P1-C15 |
| PCIe embedded USB controller | 8247-42L, 8286-41A, or 8286-42A | Un-P1 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C2 |
| PCIe3 x16 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C3 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C4 |
| PCIe3 x16 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C5 |
| PCIe3 x16 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C6 |
| PCIe3 x16 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C7 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C8 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C9 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C10 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C11 |
| PCIe3 x8 IOA card | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C12 |
| PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C14 |
| PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | 8247-42L, 8286-41A, or 8286-42A | Un-P1-C15 |
For PCI adapter FRU part numbers, see Managing PCI adapters. For embedded controller FRU part numbers, see System parts.