ANYPROC

The failing component might be one of the system processors.

To determine the location of the system processor, complete the following steps:

  1. Is a location code available in the serviceable event view for this failing item?
    • Yes: Continue with the next step.
    • No: Replace each of the system processor modules in the system unit. On multiple-drawer servers, replace the system processor modules in the primary system node and then the secondary system nodes. This ends the procedure.
  2. Is the system managed by a management console?
    • Yes: Use the management console to replace the failing item at the location that was identified in this procedure.
    • No: Continue with the next step.
  3. Use the following table to determine the service action to perform.
    Type and model Part number Description Location code Service action
    5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A See System parts. System processor modules
    • Un-P1-C32
    • Un-P1-C33
    Replace the system processor module at the location that was identified in this procedure. See Part locations and location codes.
    8408-44E or 8408-E8E See System parts. System processor modules
    • Un-P2-C2
    • Un-P2-C3
    • Un-P2-C6
    • Un-P2-C7
    Replace the system processor module at the location that was identified in this procedure. See Part locations and location codes.
    9080-MHE, 9080-MME, 9119-MHE, or 9119-MME See System parts. System processor modules
    • Un-P1-C14
    • Un-P1-C15
    • Un-P1-C18
    • Un-P1-C19
    Replace the system processor module at the location that was identified in this procedure. See Part locations and location codes.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.