This section lists error and warning messages that might be issued by the PeopleSoft access method processes.

Note:
In addition to these messages, the PeopleSoft access method also issues messages which it shares with Tivoli Workload Scheduler for Visualized Data Centers, and which are listed under the product code HTW and the component code GT (see PeopleSoft access method messages - HTWGT).
EEWN0070E
The connection to the server "server" for user "user" has failed.
Explanation:

The connection to the PeopleSoft application server could not be made or has failed. This can be due to any of the following reasons:

System action:

The PeopleSoft process cannot be submitted and monitored.

Operator response:

Verify that the values in the options file for the PeopleSoft user, its encrypted password, the application server address, and the application server port are correct.

If the option values are correct, then analyze the PeopleSoft application server log for the failed connection attempt.

When you have found the problem, correct it and retry the operation.

EEWN0100W
Option "lower_option(lower_option_value)" must have a value not greater than option "higher_option(higher_option_value)".
Explanation:

See message.

System action:

The program continues, using the default values for these options.

Operator response:

If you do not want to use the default values, stop the program, change the options so that the value of the lower_option is not greater than the value of the higher_option, and restart the program.

EEWN0101W
Option "option(value)" is not a positive value.
Explanation:

The indicated option must have a positive value.

System action:

The program continues, using the default values for this option.

Operator response:

If you do not want to use the default values, stop the program, change the option to a positive value and restart the program.

EEWN0102W
Option "option(value)" is greater than the maximum value allowed (maximum_value).
Explanation:

See message.

System action:

The program continues, using the default values for this option.

Operator response:

If you do not want to use the default values, stop the program, change the option to a value not greater than the maximum allowed, and restart the program.

EEWN0104E
The method failed to submit and monitor the PeopleSoft process to completion due to a connection failure.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Check the values of the options that define the connection (application server name or IP address, application server port, user ID, and password). If the values are correct, check if there were network failures at the time of the submission. When you have identified and fixed the problem, run the Tivoli Workload Scheduler job again.

EEWN0105E
The process submission failed due to a conflict in the PeopleSoft database. The submission was tried number_of_tries times.
Explanation:

The access method was unable to submit the PeopleSoft process. No further submission attempts will be made because the maximum number of retries (tws_retry option value) has been reached. The error was due to an unmanaged conflict between concurrent database save operations in PeopleSoft. This might occur when several Tivoli Workload Scheduler jobs submit the same PeopleSoft process, and that process uses inline bind variables.

System action:

The PeopleSoft process could not be submitted. The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Rerun the Tivoli Workload Scheduler job. If the problem persists, contact IBM Software Support for assistance.

EEWN0106E
The process submission has failed for an unknown reason.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Check the Tivoli Workload Scheduler job definition. Check that all parameters are correct and that the referred objects all exist. Retry the operation. If the problem persists, contact IBM Software Support for assistance.

EEWN0107E
The monitoring of the PeopleSoft process has failed.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Monitor the PeopleSoft process in the PeopleSoft Process Monitor page.

EEWN0110W
The process submission has failed due to a conflict in the PeopleSoft database. The submission is retried until the maximum number of retries is reached.
Explanation:

See message.

System action:

The program tries to resubmit the PeopleSoft process until the maximum number of retries is reached (the value of the tws_reply option).

Operator response:

None.

EEWN0111E
The submission, control, or monitoring of the PeopleSoft process has failed for an unknown reason. The access method does not attempt to resubmit it.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Retry the operation. If the problem persists, contact IBM Software Support for assistance.

EEWN0112E
The process submission attempt failed due to a possible connection failure.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Check the values of the options that define the connection (application server name or IP address, application server port, user ID, and password). If the values are correct, check if there were network failures at the time of the submission. When you have identified and fixed the problem, run the Tivoli Workload Scheduler job again.

EEWN0113W
The attempt to monitor the progress of the PeopleSoft job has failed. The attempt is retried until the maximum number of retries is reached.
Explanation:

See message.

System action:

The program tries to monitor the PeopleSoft process until the maximum number of retries is reached (the value of the tws_reply option).

Operator response:

None.

EEWN0119E
The retrieved run status (status) has an incorrect format.
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Resubmit the PeopleSoft process. If the problem persists, contact IBM Software Support for assistance.

EEWN0120E
An internal error "exception" has occurred. The error message is: "exception_message".
Explanation:

See message.

System action:

The Tivoli Workload Scheduler job is put into the "abend" status.

Operator response:

Resubmit the PeopleSoft process. If the problem persists, contact IBM Software Support for assistance.