subscribe iconSubscribe to this information
POWER7 information

MAP 3149

Use this MAP to resolve the following problem: Incomplete multipath connection between controller and remote controller (SRN nnnn - 9075) for a PCI-X or PCIe controller.

The possible cause is incorrect cabling between SAS RAID controllers.

Remove power from the system before connecting and disconnecting cables or devices, as appropriate, to prevent hardware damage or erroneous diagnostic results.

Step 3149-1

Review the device enclosure cabling and correct the cabling as required. To see example device configurations with SAS cabling, see Serial attached SCSI cable planning.

Step 3149-2

When the problem is resolved, see the removal and replacement procedures topic for the system unit on which you are working and do the "Verifying the repair" procedure.



Send feedback | Rate this page

Last updated: Thu, October 10, 2013