Completing the replacement process

About this task

Once you have completed all of the other installation procedures, refer to this table to determine your final steps.

If you are... Then...
Installing an additional caching module in a system with preexisting caching modules You have completed the installation process and are done with this procedure.
Replacing a failed caching module Return the failed part to IBM, following the RMA instructions shipped with the kit. Contact IBM Service and Support: 1-800-IBM-SERV (1-800-426-7378) if you need the RMA number or additional help with the replacement procedure.
Installing a caching module for the first time or upgrading the 16-GB PAMs to Flash Cache modules You must have a valid WAFL external cache software license key to complete the WAFL external cache installation. IBM provides your license key on the printed IBM System Storage N series Function Authorization form that you received from IBM with your software offering order. If you do not have the Function Authorization form, contact the IBM Manufacturing Quality Hotline.
Enable the WAFL external cache software and set the software configuration options by completing the following substeps:
  • Enable the WAFL external cache software license by entering the following command:license add license key
    • For 7-Mode, run this command from the system console prompt.
    • For a 7-Mode HA pair , run this command from each node.
    WAFL external cache functionality is enabled automatically.
  • Verify that WAFL external cache functionality is enabled by entering the following command: options flexscale.enable
    • For 7-Mode, run this command from the system console prompt.
    • For a 7-Mode HA pair , run this command from each node.
    The output should show that the functionality is on.
  • Read about the WAFL external cache configurations in the Data ONTAP 8.0 7-Mode System Administration Guide (available at: www.ibm.com/storage/support/nseries/). Knowing your application and volume configuration helps you decide what configuration options to choose.
    Note: You can set the WAFL external cache configuration options now or later, but it is recommended that you set the options now to ensure optimal performance for the system's workload.
  • Follow the applicable option-enabling procedures in the Data ONTAP 8.0 7-Mode System Administration Guide.
    Note: The option-enabling procedures in the Data ONTAP 8.0 7-Mode System Administration Guide apply to 7-Mode.
    Note: For a 7-Mode HA pair , you must configure options on each node. For Clustered Data ONTAP, you must configure the option from the nodeshell of the target node.