subscribe iconSubscribe to this information
POWER7 information

PCIe storage enclosure features

Learn about the main features of the 5888 and EDR1 PCI Express (PCIe) storage enclosures.

Table 1. PCIe storage enclosure features
Feature code 5888 EDR1
Description IBM® EXP30 Ultra solid-state drive (SSD) I/O drawer IBM EXP30 Ultra solid-state drive (SSD) I/O drawer
System connection GX++ PCIe2 x8 GX++ PCIe2 x8
Systems supported 8202-E4C, 8205-E6C, 8231-E1C, or 8231-E2C 8202-E4D, 8205-E6D, 8231-E1D, 8231-E2D, 8246-L2T, 8248-L4T, 8268-E1D, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMC, 9117-MMD, 9179-MHC, and 9179-MHD
Operating systems supported1 AIX®, Linux AIX, IBM i, Linux
High availability (HA) two-system redundant array of independent disks (RAID) Yes Yes
HA single-system RAID Yes Yes
Requires HA RAID configuration Yes Yes
JBOD drives supported No (requires drives that are formatted with 528 bytes/block) No (requires drives that are formatted with 528 bytes/block)
Internal solid-state drive (SSD) type 1.8-inch small form factor (SFF) 6 GB Dual Port serial-attached SCSI (SAS) SSD 1.8-inch small form factor (SFF) 6 GB Dual Port serial-attached SCSI (SAS) SSD
SSD drive feature codes supported ES02 ES02 (AIX and Linux), ES04 (IBM i)
Internal SSD drives Six minimum to 30 maximum Six minimum to 30 maximum
External hard disk drives (HDD) None 48 maximum
External SAS enclosures None Two 5887 disk drive enclosures maximum
Drive redundant SAS paths Two paths from each enclosure RAID module (ERM) (one path through each SAS expander) Two paths from each enclosure RAID module (ERM) (one path through each SAS expander)
Drive concurrent maintenance Yes Yes
Enclosure RAID module (ERM) PCIe2 3.1 GB cache RAID SAS enclosure 6 GB x8 PCIe2 3.1 GB cache RAID SAS enclosure 6 GB x8
ERM custom card identification number (CCIN) 57C3 57C3
ERM RAID levels RAID 0, 5, 6, and 10 with hot spare for 5, 6, and 10 RAID 0, 5, 6, and 10 with hot spare for 5, 6, and 10
ERM write cache size 3.1 GB 3.1 GB
ERM external SAS links None Two mini SAS HD 4x connectors that contain three physical links each
ERM concurrent maintenance No Yes
ERM fan assembly Two redundant fans per ERM Two redundant fans per ERM
ERM fan concurrent maintenance No Yes
Redundant power supplies Two Two
Power supply concurrent maintenance Yes Yes
1See Managing PCI adapters


Send feedback | Rate this page