FSPSP46

Some corrupt areas of flash or RAM have been detected on the service processor.

If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.

  1. Use the following table to determine the action to perform.
    System Action

    8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8233-E8B, 8236-E8C, 8268-E1D

    Replace the system backplane at location Un-P1.

    See System FRU locations for information about system FRU locations.

    8248-L4T, 8408-E8D, 9109-RMD Replace the service processor at location Un-P1-C1.

    See System FRU locations for information about system FRU locations.

    8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD Replace the service processor.
    1. If the last byte in word 3 of the SRC is a 10, replace the primary unit, service processor (Un-P1-C1).
    2. If the last byte in word 3 of the SRC is a 20, replace the secondary unit 1, service processor (Un-P1-C1).
    9119-FHB

    Using the management console, look at the platform ID in the IQYYLOG error log entry to determine the failing system controller.

    • For Platform ID 0x50xxxxxx, replace system controller A at location Un-P1-C2.
    • For Platform ID 0x51xxxxxx, replace system controller B at location Un-P1-C5.
    • For platform ID 0x86xxxxxx, replace bulk power controller A at location Un-P1-C1.
    • For platform ID 0x88xxxxxx, replace bulk power controller B at location Un-P2-C1.
    Example:
    
        |------------------------------------------|
        | Platform Event Log - 0x51EC6DB6          |
        |------------------------------------------|
        |     Private Header                       |
        |------------------------------------------|
        | Section Version   : 1                    |
        | Sub-section type  : 0                    |
        | Created by        : hlth                 |
        | Created at        : 04/21/2010 05:05:17  |
        | Committed at      : 04/21/2010 05:05:17  |
        | Creator Subsystem : FipS Error Logger    |
        | CSSVER            :                      |
        | Platform Log Id   : 0x51EC6DB6           |
        | Entry Id          : 0x51EC6DB6           |
        | Total Log Size    : 496                  |
        |------------------------------------------|

    In this example, the platform ID is 0x51, which indicates system controller B should be replaced.

    9125-F2C

    Using the management console, look at the platform ID in the IQYYLOG error log entry to determine the failing system controller.

    • For Platform ID 0x50xxxxxx, replace DCCA A at location Un-P1-C147.
    • For Platform ID 0x51xxxxxx, replace DCCA B at location Un-P1-C148.
    • For platform ID 0x86xxxxxx, replace bulk power controller A at location Un-P1-C1.
    • For platform ID 0x88xxxxxx, replace bulk power controller B at location Un-P2-C1.
    Example:
    
        |------------------------------------------|
        | Platform Event Log - 0x51EC6DB6          |
        |------------------------------------------|
        |     Private Header                       |
        |------------------------------------------|
        | Section Version   : 1                    |
        | Sub-section type  : 0                    |
        | Created by        : hlth                 |
        | Created at        : 04/21/2010 05:05:17  |
        | Committed at      : 04/21/2010 05:05:17  |
        | Creator Subsystem : FipS Error Logger    |
        | CSSVER            :                      |
        | Platform Log Id   : 0x51EC6DB6           |
        | Entry Id          : 0x51EC6DB6           |
        | Total Log Size    : 496                  |
        |------------------------------------------|

    In this example, the platform ID is 0x51, which indicates DCCA B should be replaced.

  2. To determine the action to perform, use the following table.

    System:

    Action:

    8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8248-L4T, 8268-E1D, 8408-E8D, 9109-RMD, 9119-FHB, or 9125-F2C

    Power on the system to the hypervisor standby.
    Note: Slow boot is not supported.

    8233-E8B or 8236-E8C

    Determine the level of firmware the system is running.

    Is system firmware AL710_xxx installed?

    8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD
    Determine the level of firmware the system is running.

    Is system firmware AM710_xxx installed?

    This ends the procedure.