POWER7 information

IOADPTR

The failing component is the adapter in the location specified in the SRC.

  1. Are you working from the serviceable event view and is there a card location listed with this FRU?
    • Yes: Use Table 1 to replace the adapter identified by this location code. This ends the procedure.
    • No: Determine the location of the adapter by working with the customer or your next level of support. If you cannot determine the location of the failing adapter by using SRC or resource information or the device tree, determine the adapter type from the SRC, SRC description, failing resources, or error message you are working with. Make a list of all the adapter locations of that type assigned to the partition. Continue with the next step.
  2. Have you identified a single FRU location?
    • Yes: Use Table 1 to replace the FRU you have identified. This ends the procedure.
    • No: Continue with the next step.
  3. Using the location codes you have identified, determine which system unit and expansion units have PCI adapters of this type assigned to the partition you are working with. Starting with the expansion units first, remove all of the PCI adapters of this type from one of the units (use Table 1 to guide you to the correct locations information).
    Attention:
    • Remove the PCI adapters from the system unit only after you have tried all of the expansion units first.
    • Do not remove any FRUs with embedded adapters, only FRUs in PCI card slots.
    Continue with the next step.
  4. Reinstall one of the adapters and power on the unit. Continue with the next step.
  5. Does the problem recur?
    • Yes: The adapter you just reinstalled is the failing item and needs to be replaced (use Table 1 to guide you to the correct locations information). This ends the procedure.
    • No: Continue with the next step.
  6. Have you reinstalled all of the adapters on the unit you're currently working with?
    • Yes: Continue with the next step.
    • No: Return to step 4 and reinstall the next adapter on this unit.
  7. Are there any units (including the system unit) on which you have not yet removed and reinstalled the PCI adapters?
    • No: Continue with the next step.
    • Yes: Return to step 3 and work with another unit.
  8. See Card positions to determine whether the system unit or any of the expansion units have an embedded adapter of the type you are working with. Is there such an embedded adapter?
    • No: The problem might be intermittent. Contact your next level of support. This ends the procedure.
    • Yes: The FRU with the embedded adapter is the failing item and needs to be replaced. Use Table 1 to replace the FRU at the location specified in the card position table. Repeat this step for each expansion unit with an embedded adapter assigned to the partition, and then for the system unit. This ends the procedure.
Table 1. Failing items for symbolic FRU IOADPTR
FRU name (replace FRUs in order, one at a time, starting with the primary unit and then the secondary units if applicable) Type and model Location
PCI adapter in slot 1 8202-E4B, 8205-E6B Un-P1-C4
PCI adapter in slot 2 8202-E4B, 8205-E6B Un-P1-C5
PCI adapter in slot 3 8202-E4B, 8205-E6B Un-P1-C6
PCI adapter in slot 4 8202-E4B, 8205-E6B Un-P1-C7
PCI expansion feature (riser) - PCI adapter in slot 5 8202-E4B, 8205-E6B Un-P1-C1-C1
PCI expansion feature (riser) - PCI adapter in slot 6 8202-E4B, 8205-E6B Un-P1-C1-C2
PCI expansion feature (riser) - PCI adapter in slot 7 8202-E4B, 8205-E6B Un-P1-C1-C3
PCI expansion feature (riser) - PCI adapter in slot 8 8202-E4B, 8205-E6B Un-P1-C1-C4
Host Ethernet adapter card 8202-E4B, 8205-E6B Un-P1-C3
Embedded Ethernet adapter 8202-E4B, 8205-E6B Un-P1
Embedded USB controller 8202-E4B, 8205-E6B Un-P1
System backplane 8202-E4B, 8205-E6B Un-P1
PCI adapter in slot 1 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C2
PCI adapter in slot 2 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C3
PCI adapter in slot 3 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C4
PCI adapter in slot 4 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C5
PCI adapter in slot 5 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C6
PCI adapter in slot 6 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C7
PCI expansion feature (riser) - PCI adapter in slot 7 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C1-C1
PCI expansion feature (riser) - PCI adapter in slot 8 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C1-C2
PCI expansion feature (riser) - PCI adapter in slot 9 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C1-C3
PCI expansion feature (riser) - PCI adapter in slot 10 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1-C1-C4
Embedded Ethernet adapter 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1
Embedded USB controller 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1
System backplane 8202-E4C, 8202-E4D, 8205-E6C, 8205-E6D Un-P1
PCI adapter in slot 1 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C2
PCI adapter in slot 2 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C3
PCI adapter in slot 3 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C4
PCI adapter in slot 4 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C5
PCI adapter in slot 5 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C6
PCI adapter in slot 6 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1-C7
System backplane, embedded USB controller, and embedded Ethernet adapter 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D Un-P1
PCI adapter in slot 1 8231-E2B Un-P1-C3
PCI adapter in slot 2 8231-E2B Un-P1-C4
PCI adapter in slot 3 8231-E2B Un-P1-C5
PCI adapter in slot 4 8231-E2B Un-P1-C6
System backplane, embedded USB controller, and embedded Ethernet adapter 8231-E2B Un-P1
Host Ethernet adapter card 8231-E2B Un-P1-C2
PCI adapter in slot 1 8233-E8B, 8236-E8C Un-P1-C1
PCI adapter in slot 2 8233-E8B, 8236-E8C Un-P1-C2
PCI adapter in slot 3 8233-E8B, 8236-E8C Un-P1-C3
PCI adapter in slot 4 8233-E8B, 8236-E8C Un-P1-C4
PCI adapter in slot 5 8233-E8B, 8236-E8C Un-P1-C5
Embedded Ethernet adapter 8233-E8B, 8236-E8C Un-P1
Embedded USB controller 8233-E8B, 8236-E8C Un-P1
System backplane 8233-E8B, 8236-E8C Un-P1
PCI adapter in slot 1 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C1
PCI adapter in slot 2 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C2
PCI adapter in slot 3 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C3
PCI adapter in slot 4 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C4
PCI adapter in slot 5 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C5
PCI adapter in slot 6 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C6
I/O backplane, embedded media device controller, embedded serial controller 8248-L4T, 8408-E8D, 9109-RMD Un-P2
Integrated multifunction card 8248-L4T, 8408-E8D, 9109-RMD Un-P2-C8
PCI adapter in slot 1 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C1
PCI adapter in slot 2 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C2
PCI adapter in slot 3 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C3
PCI adapter in slot 4 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C4
PCI adapter in slot 5 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C5
PCI adapter in slot 6 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C6
I/O backplane, embedded USB controller, and embedded Ethernet adapter 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2
Host Ethernet adapter card 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD Un-P2-C8
PCI adapter in slot 1 5796, 7314-G30 Un-P1-C1
PCI adapter in slot 2 5796, 7314-G30 Un-P1-C2
PCI adapter in slot 3 5796, 7314-G30 Un-P1-C3
PCI adapter in slot 4 5796, 7314-G30 Un-P1-C4
PCI adapter in slot 5 5796, 7314-G30 Un-P1-C5
PCI adapter in slot 6 5796, 7314-G30 Un-P1-C6
I/O backplane 5796, 7314-G30 Un-P1
I/O adapter 5802, 5877 Un-P1-Cx
I/O adapter 5803, 5873 Un-P1-Cx, Un-P2-Cx

For PCI adapter FRU part numbers, see Managing PCI adapters. For embedded controller FRU part numbers, see System parts.