TCP/IP default ATM values
Valid ATM network adapter attributes can have their values changed using the Network Interface Selection menu in SMIT.
| Attribute | Default value | Possible values |
|---|---|---|
| netaddr | ||
| netmask | ||
| state | up | up, down, detach |
| Connection Type | svc_s | svc_c, svc_s, pvc |
| ATM Server Address | ||
| Alternate Device | ||
| idle timer | 60 | 1 through 60 |
| Best Effort Bit Rate (UBR) in kbits/sec | 0 | 1 through 155,000 |
The following valid ATM network device driver attribute is shown along with its default values as displayed under the Network Interface Drivers menu in SMIT.
| Attribute | Default value | Possible values |
|---|---|---|
| mtu | 9180 | 1 through 64K |
Note: Network Administrators need to exercise caution while changing
MTU size from default to some other value. The MTU size needs to
be coordinated with other stations on the network.
If PVCs are to be used on an interface, the VPI:VCIs needs to be
defined. This is performed through the Network Interface Selection
Menu. The PVCs for IP over ATM Network option on
this menu is used to list, add, change, or remove PVCs.