Using the Duplicate Token Utility
There is no panel interface to this utility. The key data set must be specified as either a CKDS or a PKDS.
- Invoke the program as a batch job.
- You must have UPDATE authority to the profile in the DATASET class
covering the KDS.To generate a report for a CKDS with the fully qualified data set name of ICSF.HCR7751.CKDS, use this JCL example:
//DUTIL EXEC PGM=CSFDUTIL //SYSOUT DD SYSOUT=* //SYSIN DD * CKDSN(ICSF.HCR7751.CKDS) /* //
The supported option is either:
CKDSN(fully-qualified-CKDS-name)
or
PKDSN(fully-qualified-PKDS-name)When you invoke the program as a batch job, you receive the return and reason code in a message when the job completes. The return codes are explained in Return and reason codes for the CSFDUTIL program.
The data set name is assumed to be fully-qualified.
Note: Prior to analyzing the current CKDS or PKDS, consider temporarily disallowing dynamic CKDS and PKDS update services. If the analysis is to be performed on a CKDS or PKDS which is shared by members of a sysplex, dynamic updates of the CKDS and PKDS should be disabled on all sysplex systems until the analysis job is complete.