Cataloged failures

If any of these data sets are not cataloged, one of the following dialog messages will be displayed:
ICSF COULD NOT SUFFICIENTLY RESOLVE SYSTEM CATALOG INFORMATION FOR ONE OF THE 
CURRENTLY ACTIVE OR NEW DATA SETS. REFER TO THE ICSF JOBLOG(S) FOR ADDITIONAL 
INFO. IBM DIAGNOSTIC INFORMATION: RROPRC=0000000C RROPRSN=00000C2C SUPPRC=00000000 
SUPPRSN=00000000 FLAGS=02800000
ICSF SUFFERED AN UNEXPECTED I/O ERROR REFERENCING OR UPDATING ONE OF THE ACTIVE, 
NEW OR BACKUP DATA SETS. REFER TO THE ICSF JOBLOG(S) FOR ADDITIONAL INFO. IBM 
DIAGNOSTIC INFORMATION: RROPRC=0000000C RROPRSN=00002740 SUPPRC=0000000C 
SUPPRSN=00001790 FLAGS=41800000
In addition, a CSFM619I and/or a CSFM623I message will be written to the ICSF job log.

To correct this problem, make sure the necessary data sets are cataloged and retry the function.