DFHTC2515 date time applid Output area exceeded {on line w/term | at term } termid {, trans } tranid {, rel line=} rr,time
Explanation
One of the following has occurred:
-
The terminal I/O area (TIOA) is not large enough to contain both the data and carrier control characters.
-
The TIOA data length is greater than the TCAM block size specified in the DFHTCT TYPE=SDSCI macro.
-
The application requires a TIOA larger than 32767 bytes.
System action
The write request is not executed, the terminal write storage is freed (if possible), and the transaction terminates abnormally. CICS processing continues.
User response
Ensure that application programs do not set the value of TIOATDL greater than the TIOA GETMAIN size, and that the TIOA data length is not greater than the TCAM blocksize. Also ensure that the application program does not require a TIOA larger than 32767 bytes.
Module
DFHTACPXMEOUT parameters/Message inserts
- date
- time
- applid
- Value chosen from the following options:
1=on line w/term , 2=at term - termid
- Value chosen from the following options:
1=, trans - tranid
- Value chosen from the following options:
1=, rel line= - rr
- time
Destination
CSTL