DFHMN0106 applid Unable to read the catalog record for the Monitoring Domain.
Explanation
The monitoring domain has attempted to re-establish the status of the monitoring classes and the monitoring control table suffix under which it was running during the last execution of CICS. But it was unable to successfully read the record from the global catalog.
System action
An exception entry is made in the trace table.
System initialization continues with the supplied system initialization parameters.
Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
Investigate the cause of the error using any dump or other diagnostic messages which have been issued (for example, from VSAM or MVS).
If the problem has been caused by an I/O error, there will be an earlier CICS message from the catalog. Follow the user response for this message.
If the problem has been caused by an invalid data length, there will be an exception trace entry in the trace table.
Module
DFHMNDMXMEOUT parameters/Message inserts
- applid
Destination
Console