subscribe iconSubscribe to this information
POWER7 information

Removing and installing a fan assembly for an EDR1 PCIe storage enclosure

Use this procedure to service a fan assembly concurrently or nonconcurrently for the EDR1 PCIe storage enclosure (EXP30 Ultra SSD I/O Drawer).

Attention: Failure to follow the steps sequentially for this field replaceable unit (FRU) removal or installation might result in damage to the FRU or system.

Use the following precautions whenever you handle electronic components or cables:

To remove and install a fan assembly, complete the following steps:

  1. Use the service indicator light-emitting diodes (LEDs) to help identify the part. For instructions, see Identifying a part.
  2. Remove the enclosure RAID module (ERM) assembly from the PCIe storage enclosure. For instructions, see Removing and installing an enclosure RAID module assembly for an EDR1 PCIe storage enclosure.
  3. Remove the fan assembly from the ERM assembly:
    1. Place the ERM assembly on a flat surface.
    2. Press the release button (A), as shown in the following figure, to raise the fan assembly out of the ERM assembly.
    3. Grasp the fan assembly (B) and remove it from the ERM assembly.
    Figure 1. Removing the fan assembly from the ERM assembly
    Removing the fan from the ERM assembly
  4. Install the fan assembly:
    1. Insert the fan assembly into the ERM assembly until it stops.
    2. Install the ERM assembly into the PCIe storage enclosure. For instructions, see Removing and installing an enclosure RAID module assembly for an EDR1 PCIe storage enclosure.