The cache battery pack should be in an error state before
you replace it.
To prevent possible data loss, ensure that the cache battery pack
is in an error state before replacing it. This will ensure all cache
data is written to disk before battery replacement. Forcing the battery
error will result in the following:
- The system logs an error.
- Data caching becomes disabled on the selected controller.
- System performance could become significantly degraded until the
cache battery pack is replaced on the selected controller.
- The Battery pack can be safely replaced field
on the controller rechargeable battery information screen indicates
Yes.
- Cache data present LED stops flashing. See the feature descriptions
and the figures in the Rechargeable battery maintenance section
to determine if your adapter has a cache data present LED and the
location of the LED.
This error state requires replacement of the cache battery. Ensure
that you have the correct type and quantity of cache battery packs
to do the replacement. To resume normal operations, replace the cache
battery pack.
The cache battery pack for the 572F storage I/O adapter and the
575C auxiliary cache adapter is contained in a single battery field
replacement unit (FRU) that is physically located on the 575C auxiliary
cache adapter. The functions of forcing a battery pack error and starting
the adapter cache on either adapter in the card set results in the
same function automatically being performed on the other adapter in
the card set.