DMT945E Protocol error detected by link linkid, code code -- link being deactivated Link deactivated -- reason
Explanation
The other side of the link connection found a
protocol error. The message displays a hexadecimal reason code and
a reason which indicate the type of protocol violation encountered.
The reason codes and reasons are:
- 08xx remote system in SHUTDOWN
- The remote system is shutting down its NJE operations and cannot accept a file at the moment.
- 0C04 stream not supported
- RSCS sent a file on a stream that the remote system cannot receive.
- 0C08 stream drained
- RSCS sent a file on a stream that the remote system is not receiving at the moment.
- 0C0C unknown stream
- RSCS sent a file on a stream that the remote system did not recognize.
- 0C10 FCS conflict
- RSCS sent a file on a stream that conflicts with another active stream.
- 0Cxx RIF received for unsupported stream
- RSCS sent a file on a stream that the remote system cannot receive.
- 1004 insufficient real storage
- The remote system lacks enough real storage to process a file.
- 1008 insufficient virtual storage
- The remote system lacks enough virtual storage to process a file.
- 100C insufficient spool space
- The remote system lacks enough free spool space or spool file numbers to process a file.
- 1010 insufficient CPU resources
- The remote system lacks enough CPU resources (other than those listed) to process a file.
- 10xx lack of resources
- The remote system lacks enough resources (other than those listed) to process a file.
- 1404 operator issued HOLD command
- The remote operator issued a HOLD command for the connection.
- 1408 operator issued STOP command
- The remote operator issued a STOP command for the connection.
- 140C operator issued FLUSH command
- The remote operator issued a FLUSH command for the file.
- 14xx operator issued command
- The remote operator issued an RSCS command (other than those listed) for the connection or stream.
- 1804 last transmission not correctly terminated
- The remote system did not receive data from RSCS that it had expected.
- 1808 compression or compaction error detected
- The remote system received a data compression or compaction instruction from RSCS that it did not understand.
- 180C records sent out of sequence
- The remote system did not receive data records from RSCS that it had expected.
- 1810 mixed RCBs encountered
- The remote system received data for more than one stream in a single buffer from RSCS.
- 1814 undefined RCB/SRCB combination
- The remote system received a data record type from RSCS that it did not understand.
- 1818 data being received exceeds expected length
- The remote system attempted to send a data buffer with a length greater than RSCS expected.
- 18xx protocol violation
- The remote system received a protocol violation (other than those listed) for the connection or stream.
- 1C04 unsupported device
- A file was created on another system with a virtual spool output device that is not supported at this node. The file cannot be processed on this node.
- 1Cxx datastream error
- The remote system would not accept the file format.
- 20xx file rejected by exit or security routine
- An exit routine or security system on the remote system rejected the file.
- xxxx unknown reason
- The remote system supplied no reason code or supplied a reason code unknown to RSCS.
System action
RSCS deactivates the link, and normal processing continues.
User response
Restart the link, and try to get a trace of the link activity that led up to the protocol violation. Contact your RSCS support personnel.
Destination
R, SCO