SEND_ONLY statement
The SEND_ONLY statement can be coded stand-alone in the OMPROUTE configuration file to apply to all RIP interfaces.
Syntax
Parameters
- (values)
- Specifies broadcast restrictions. Multiple values can be coded
by separating the values with commas, unless ALL is coded. The valid
values are:
- ALL
- Specifies no broadcast restrictions.
- VIRTUAL
- Broadcasts virtual IP addresses.
- DEFAULT
- Broadcasts the default route.
- DIRECT
- Broadcasts direct routes.
- TRIGGERED
- Only broadcast routes when requested or when a route becomes inactive (metric 16).
When specified on the SEND_ONLY statement in the OMPROUTE configuration file, it applies to all RIP_Interfaces. The SEND_ONLY parameter can also be coded on the RIP_INTERFACE statement. When specified on the RIP_INTERFACE statement, the SEND_ONLY parameter applies only to the corresponding RIP_Interface.