GIM39311E SHELL SCRIPT shellscr PROCESSING TO DELETE elmtype elmname IN THE library LIBRARY FAILED FOR SYSMOD sysmod. SEQUENCE NUMBER seqno.

Explanation

shellscr
shell script name
elmtype
element type
elmname
element name
library
ddname of the library that contains the element
sysmod
SYSMOD ID
seqno
utility sequence number
Shell script processing to delete the indicated element has failed. The utility sequence number matches the sequence number of the shell script output in the PRINT data set.
Note: SYSPRINT is SMP/E's default print data set, and is used if no PRINT subentry was specified in the active UTILITY entry for the HFSCOPY utility.

System action

SYSMOD processing stops.

Programmer response

Check the shell script output in the PRINT data set for the cause of the error. You can use the utility sequence number as an index into SYSPRINT to find the output.