GIM35501E AN ERROR OCCURRED DURING PROCESSING OF THE enttype ENTRY FOR SYSMOD sysmod IN THE library LIBRARY.
Explanation
- enttype
- entry type
- sysmod
- SYSMOD ID
- library
- ddname of the library
An error occurred while SMP/E was processing
the indicated SYSMOD.
- If the entry type is MCS, SMP/E found an error when it was checking
the MCS entry on the SMPPTS data set. The error could be one of the
following:
- An I/O error
- A mismatch between the MCS and SYSMOD entries on the SMPPTS.
- If the entry type is not MCS, look at the preceding SMP/E output to find the cause of the error for the indicated entry type.
System action
SYSMOD processing stops.
Programmer response
Do one of the following:
- If the entry type is MCS, reject the SYSMOD and receive it again.
- If any other case, follow the recommended action in the preceding error messages.