GIM20202I obtnfixd TOTAL BYTES ARE RESERVED FOR ICT FIXED DATA, OF WHICH, usedfixd BYTES ARE USED. obtnvard TOTAL BYTES ARE RESERVED FOR ICT VARIABLE DATA, OF WHICH, usedvard BYTES ARE USED.

Explanation

obtnfixd
amount of storage obtained for the ICT fixed data
usedfixd
amount of storage used for the ICT fixed data
obtnvard
amount of storage obtained for the ICT variable data
usedvard
amount of storage used for the ICT variable data

SMP/E could not allocate internal tables because of insufficient storage.

System action

The messages that follow in the output listing show the actions taken by SMP/E.

Programmer response

For the APPLY, ACCEPT, or RESTORE commands, check if the amount of storage used for the ICT fixed data area (usedfixd) is approximately 64MB. If it is, decrease the number of SYSMODs that SMP/E is processing in the run. Otherwise, do one or more of the following:
  • Increase the REGION parameter on the EXEC statement
  • Decrease the number of SYSMODs that SMP/E is processing in this run
  • Decrease the PEMAX value in the OPTIONS entry being used.
For the LINK MODULE command, do one or more of the following:
  • Increase the REGION parameter on the EXEC statement
  • Decrease the PEMAX value in the OPTIONS entry being used

Rerun the job. If storage is still insufficient, contact the IBM® Support Center.