IEA386I text

Explanation

Where text is: Start of change
hh.mm.ss TIMING STATUS
SYNCHRONIZATION MODE = mode
THIS SERVER IS A STRATUM n
CTN ID = ctnid  [ETS ID = etsid (englishets)]
ETS Timing Precision = p Start of changeETS ID = DPTPEnd of change
THE STRATUM 1 NODE ID = cpcid
NUMBER OF TIMING LINKS = ll
optional text
End of change

In the message text:

hh.mm.ss
The hour (00-23), minute (00-59), and second (00-59) that the system issued this message.
mode
One of the following:
  • STP
  • ETR
  • LOCAL
n
Stratum level
ctnid
Coordinated Timing Network (CTN) ID
Start of changeetsid and englishetsEnd of change
External Time Source (ETS) ID. STP timing mode can have the following ETS:
  • CNTP - NTP (Network Timing Protocol) without PPS (Pulse Per Second)
  • CNTX - NTP without PPS via secondary
  • PPSN - NTP with PPS
  • PPSX - NTP with PPS via secondary
  • CPTP - PTP (Precision Time Protocol) without PPS
  • CPTX - PTP without PPS via secondary
  • PPPS - PTP with PPS
  • PPPX - PTP with PPS via secondary
  • Start of changeCMAN - Console manually set timeEnd of change
  • Start of changePRTF - PRT Update FailureEnd of change
  • Start of changeUNIN - Uninitialized. PRT not setEnd of change
  • Start of changeMRGE - Merging with another Stratum 1End of change
  • Start of changezzzz - ETS ID is not validEnd of change
  • **** - The ETS ID was unavailable at the time of the command
  • Start of changep - ETS level of timing precisionEnd of change
  • Start of changeETS = DPTP - Direct attachment using PTPEnd of change
Start of changepEnd of change
Start of changeETS level of timing precision
  • 1 = Lowest level of ETS timing precision. You should change to a higher level of ETS timing precision, NTP or PTP.
  • 2 = This level of ETS timing precision is acceptable, but it does not take advantage of the PPS (Pulse Per Second) signal to achieve an even higher level of timing precision. Financial and banking institutions should change to a higher level of timing precision.
  • 3 = Current highest level of ETS timing precision. This level uses the PPS (Pulse Per Second) signal.
  • U = The ETS has an unknown level of timing precision.
End of change
cpcid
CPC node ID of the stratum 1 server (tttttt.mmm.nnn.pp.ssssssssssss)
ll
The number of links, in decimal.
optional text
One or more of the following lines are issued:
  • One of these optional lines can be issued, but only on the corresponding server type.
    [THIS IS THE PREFERRED TIME SERVER]
    [THIS IS THE BACKUP TIME SERVER]
    [THIS IS THE ARBITER SERVER]
  • If one of the three server type lines was issued, then one (or two) of the following lines might be issued.
    [THIS SERVER HAS NO LINK TO THE 
    BACKUP TIME SERVER]
    [THIS SERVER HAS NO LINK TO THE 
    PREFERRED TIME SERVER]
    [THIS SERVER HAS NO LINK TO THE 
    ARBITER SERVER]
  • If one of the three server type lines was issued, then one (or two) of these lines might be issued.
    [THIS STP NETWORK HAS NO BACKUP TIME SERVER]
    [THIS STP NETWORK HAS NO SERVER
     TO ACT AS ARBITER]
  • The following two optional lines are never issued on the active Primary Stratum 1 or active Alternate Stratum 1 servers.
    [THIS SERVER HAS ONLY A SINGLE SOURCE
     OF TIMING SIGNALS]
    [NUMBER OF USABLE TIMING LINKS = ll
  • This optional line is only issued on a Primary S1 or Alternate S1.
    [THERE IS ONLY ONE LINK BETWEEN THE 
    PREFERRED AND BACKUP TIME SERVER]
  • This optional line is issued if only one physical timing link which is usable as a source of time.
    [THIS SERVER HAS ONLY ONE USABLE PHYSICAL TIMING LINK AVAILABLE]
    [NUMBER OF USABLE TIMING LINKS]
    Note: The [NUMBER OF USABLE TIMING LINKS] includes any virtual links defined. As such, it is possible for this optional line to be issued even if the number of usable timing links is greater than one.
  • One of these optional lines might be issued instead of any of the other optional lines.
    [STP DATA NOT AVAILABLE AT THIS TIME. 
    TRY AGAIN LATER]
    [THE STP FACILITY IS NOT AVAILABLE]
  • This optional line is issued if the I/O Configuration Control Authority (CCA) has not been enabled for the LPAR:
    [CONFIGURATION REDUNDANCY CHECKING NOT POSSIBLE FROM THIS LPAR]
    
  • This optional line is issued if STP link information could not be obtained:
    [STP DATA NOT AVAILABLE AT THIS TIME. 
    TRY AGAIN LATER]
  • This optional line is issued if STP mode was requested but the system is running in LOCAL synchronization mode:
    [THE STP FACILITY IS NOT AVAILABLE]   
  • Start of changeIf the ETS is one of the PTP ETS IDs, then the following optional line is issued:
    PTP Grandmaster ID = xxxxxx.xxxx.xxxxxx
    where xxxxxx.xxxx.xxxxxx is a unique clock identifier for the PTP Grandmaster ID. It is constructed from the MAC address of the clock device, and it is also displayed on the STP panels on the SE/HMC.End of change

System action

The system continues processing.

Operator response

If etsid is ****, issue the DISPLAY ETR command again. If etsid continues to display ****, notify the System Programmer.

System programmer response

If etsid continues to display ****, contact the IBM Support Center.

User response

N/A

Problem determination

N/A

Source

Timer supervision

Module

IEATDISP

Routing code

*

Descriptor code

5

Automation

None.