Header/Self-defining Section
This section contains the common SMF record headers fields and the triplet fields (offset/length/number), if applicable, that locate the other sections on the record.
| Offsets | Name | Length | Format | Description | |
|---|---|---|---|---|---|
| 0 | 0 | SMF60LEN | 2 | binary | Record length. This field and the next field (total of four bytes) form the RDW (record descriptor word). See Standard and Extended SMF record headers for a detailed description. |
| 2 | 2 | SMF60SEG | 2 | binary | Segment descriptor (see record length field). |
| 4 | 4 | SMF60SYS | 1 | binary | System indicator:
|
| 5 | 5 | SMF60RTY | 1 | binary | Record type 60 (X'3C'). |
| 6 | 6 | SMF60TME | 4 | binary | Time since midnight, in hundredths of a second, that the record was moved into the SMF buffer. |
| 10 | A | SMF60DTE | 4 | packed | Date when the record was moved into the SMF buffer, in the form 0cyydddF. See Standard and Extended SMF record headers for a detailed description. |
| 14 | E | SMF60CPU | 4 | EBCDIC | System identification (from the SID parameter). |
| 18 | 12 | SMF60SBS | 4 | Reserved. | |
| 22 | 16 | SMF60SUB | 2 | EBCDIC | Indicates that the VVR is updated, deleted, or
inserted in the VVDS:
|
| 24 | 18 | SMF60POF | 4 | binary | Offset of product section from start of record, including the record descriptor word (RDW). |
| 28 | 1C | SMF60PLN | 2 | binary | Length of product section. |
| 30 | 1E | SMF60PNO | 2 | binary | Number of product sections. |
| 32 | 20 | SMF60DOF | 4 | binary | Offset of data section from start of record, including the record descriptor word (RDW). |
| 36 | 24 | SMF60DLN | 2 | binary | Length of data section. |
| 38 | 26 | SMF60DNO | 2 | binary | Number of data sections. |
| Product and data section: | |||||
| 40 | 28 | SMF60VER | 2 | EBCDIC | Version of the type 60 records. |
| 42 | 2A | SMF60PNM | 8 | EBCDIC | Catalog management product identifier. |
| 50 | 32 | SMF60JNM | 8 | EBCDIC | Job name. The job log identification consists of the job name, time, and date that the reader recognized the JOB card (for this job). |
| 58 | 3A | SMF60RST | 4 | binary | Time since midnight, in hundredths of a second, that the reader recognized the JOB card (for this job). |
| 62 | 3E | SMF60RDT | 4 | packed | Date when the reader recognized the JOB card for this job, in the form 0cyydddF. See Standard and Extended SMF record headers for a detailed description. |
| 66 | 42 | SMF60UID | 8 | EBCDIC | User-defined identification field (taken from common exit parameter area, not from USER=parameter on job statement). |
| 74 | 4A | SMF60FNC | 1 | Reserved. | |
| 75 | 4B | SMF60CNM | 44 | EBCDIC | Name of VSAM volume data set (VVDS) in which entry is made. |
| 119 | 77 | SMF60TYP | 1 | EBCDIC | Entry type identifier.
|
| 120 | 78 | SMF60ENM | 44 | EBCDIC | Entry name. |
| 164 | A4 | SMF60NNM | 44 | Reserved. | |
| 208 | D0 | SMF60CRC | variable | binary | VVR or NVR (the length of the VVR or NVR is contained in the first two bytes of this field). If SMFVER=2, an 8-byte field is at the end of this record which contains the time (recorded in microseconds) needed to complete the VVDS request (ADD, DELETE, or INSERT). This field exists only for an SMF type 60 record. |