IDC3009I catalog RETURN CODE IS return-code - REASON CODE IS IGGOCLaa - reason-code sfi
Explanation
- aa
- The module identifier.
- return-code
- The return code
- reason-code
- The reason code
- sfi
- The subfunction (SFI) field information. If present, it is documented under the specific return-code reason-code.
For the explanations of a return code and reason code, find the heading for the return code in the following text and then scan for the associated reason code.
If you are using Library Server, to find the explanations of a return code and reason code quickly, enter the following search argument:
IDC3009I return-code reason-code
IDC3009I 4 34IDC3009I rcreturn-codeFor example, for the general description of return code 4, enter IDC3009I
rc4.
If the search takes you to a description of the reason code "x", it means the reason code that you received is one of a group of reason codes that have a common description. Most of these reason codes represent internal logic errors, and they indicate that you should contact the IBM® Support Center.
System action
The system ends processing associated with the error return code.
Operator response
None, unless indicated for specific return and reason codes
System programmer response
If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem-reporting databases for a fix for the problem. If no fix exists, contact the IBM Support Center. Provide the JCL and the SYSOUT output for the job.
Some return and reason code combinations might also produce an SVC dump. This dump should also be provided with any other documentation supplied to the IBM Support Center.
Descriptions of the return codes and reason codes follow.
RETURN CODE 4 Explanation: The system encountered an error while performing open/close processing for a catalog.| Reason Code | Description |
|---|---|
| x | Explanation: An internal error has occurred during Catalog
processing. Programmer Response: Contact the IBM Service Center. An SVC dump may have been produced for this error. |
| 2 | Explanation: An error occurred while opening a new catalog
that is being defined, or the master catalog. Programmer Response: Check for open/close problem determination messages in the job stream output. |
| 6 | Explanation: A request has referenced a catalog while
catalog management is processing, or after catalog management has processed, an access method
services DELETE command for the specific catalog. Programmer Response: The catalog needed for the request has been deleted. If needed, the catalog must be redefined before attempting the request again. |
| 8 | Explanation: An incorrect access method control block (ACB)
was supplied to catalog management for a catalog to be used during a catalog request.
Programmer Response: Contact your programming support personnel. |
| 23 | Explanation: While performing a GETMAIN from the requested
subpool, the VSAM volume data set (VVDS) manager protocol module returned an error. Programmer Response: Increase the size of the CSA or run the job again when more CSA is available. |
| 25 | Explanation: Unable to get CSA storage (subpool
241). Programmer Response: Increase the size of CSA or run the job when more CSA is available. |
| 26 | Explanation: Unable to get storage for scheduler workarea
(subpool 252). Programmer Response: Increase the REGION size. |
| 27 | Explanation: Unable to get CSA for catalog (subpool 241).
Programmer Response: Increase the size of CSA or run the job when more CSA is available. |
| 30 | Explanation: Unable to get in subpool 252. Programmer Response: Increase the REGION size. |
| 31 | Explanation: The VVDS manager encountered an error processing a VSAM volume record (VVR) request. |
| 32 | Explanation: The system was unable to complete verification
that the required volume is mounted. Programmer Response: Ensure that the unit is available for mounting and that the correct volume is mounted. |
| 34 | Explanation: An attempt to open a catalog could not find the
VVR record for the catalog. Programmer Response: It is possible that the catalog name is still defined in the master catalog but does not physically exist on the expected volume. This is usually a result of re-initializing the volume without doing an EXPORT DISCONNECT of any user catalogs on the volume. |
| 60 | Explanation: Unable to get storage in subpool 252 (for EOV)
or in subpool 253 (for CLOSE). Programmer Response: Increase the REGION size. |
| 83 | Explanation: The catalog has been deleted, and CAXWA is
still on the chain until all jobs allocated to it end or logoff. Programmer Response: Do not use the catalog, or a new catalog with the same name, until all jobs allocated to the old catalog end or logoff. |
| 84 | Explanation: CAXWA count of active users has reached 32767,
the maximum allowed. Programmer Response: Do not use the catalog until one of the current jobs allocated to it ends or logs off. |
| 85 | Explanation: Unable to get CSA for the catalog ACB or for
the PCTT (subpool 241) Programmer Response: Increase the size of the CSA or run the job when more CSA is available. |
| 86 | Explanation: An error occurred while opening the catalog.
Programmer Response: See associated message IEC161I and/or IEC331I for information about the OPEN error. The catalog might be damaged. Run the DIAGNOSE or EXAMINE command to analyze the catalog. |
| 102 | Explanation: An invalid catalog ACB address was passed in
the catalog parameter list. Programmer Response: Point the ACB pointer passed in the parameter list to the valid ACB of a user catalog. |
| 104 | Explanation: A necessary catalog could not be dynamically
allocated in the catalog address space, and the catalog parameter list indicated dynamic allocation
in the callers address space was not allowed. Programmer Response: Check for allocation problem determination messages in the job stream output. Follow the programmer response for these messages. |
| 106 | Explanation: A necessary catalog could not be dynamically
allocated in the catalog address space, and the catalog parameter list indicated dynamic allocation
in the callers address space was not allowed. Programmer Response: Check for allocation problem determination messages in the job stream output. Follow the programmer response for these messages. |
| 108 | Explanation: A necessary catalog could not be dynamically
allocated in the catalog address space, and the catalog parameter list indicated dynamic allocation
in the callers address space was not allowed. Programmer Response: Check for allocation problem determination messages in the job stream output. Follow the programmer response for these messages. |
| 114 | Explanation: A catalog needed for the request could not be
allocated to the catalog address space, and the caller did not request that it be allocated to the
callers address space. Programmer Response: When a catalog cannot be dynamically allocated to the catalog address space, it must be allocated to the user address space before the catalog request is issued. |
| 116 |
Explanation: The CAS unallocation lock was not available. Programmer Response: Contact the IBM Support Center. |
| 118 | Explanation: The catalog needed for this request has been
deleted. Programmer Response: Redefine the deleted catalog and reissue the request. |
| 120 | Explanation: The master catalog connector record was not
found for the named catalog. Programmer Response: Enter the access method services LISTCAT command to display the entries in the master catalog. If the user catalog is not listed, enter the access method services IMPORT CONNECT command to connect the catalog. If the user catalog data set name is listed, ensure that the entry is for a user catalog. |
| 122 | Explanation: The master catalog connector record was not
found for the named catalog. Programmer Response: Enter the access method services LISTCAT command to display the entries in the master catalog. If the user catalog is not listed, enter the access method services IMPORT CONNECT command to connect the catalog. If the user catalog data set name is listed, ensure that the entry is for a user catalog. |
| 124 | Explanation: An error occurred while opening the
catalog. Programmer Response: See associated messages IEC161I and IEC331I, or both, for more information about the OPEN error. |
| 134 | Explanation: A zero UCB pointer was found in an internal catalog
control block of an ICFCATALOG. Programmer Response: Send in the 4-134 dump produced to the IBM support center. Issue the MODIFY command F CATALOG,ALLOCATE(catalog name) for the catalog in error and reissue the failing request. If that still does not resolve the issue, contact the IBM support center. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: An entry was not found on LOCATE REQUEST.
Programmer Response: Ensure that the proper entry was specified. |
| 2 | Explanation: The catalog cluster record was not found.
Programmer Response: Call your programming support personnel. |
| 6 | Explanation: No record was found from record management.
Programmer Response: Ensure that the entry name is spelled correctly. In the instance of an improper DELETE command entry type, either remove the type specification or correct it. Check also that the proper catalog is being searched for the name you specified. |
| 8 | Explanation: A request to place a record by key into a
catalog resulted in a duplicate key error from VSAM. Programmer Response: Ensure that the entry name is spelled correctly and that the proper catalog is being used. |
| 12 | Explanation: An incorrect entry type occurred for locate on
the entry named. The data set was not found in a catalog. Programmer Response: Ensure that the proper data set name was specified in the job control language DD statement. |
| 14 | Explanation: A generation data group (GDG) entry type for
locate did not find the specified entry in a catalog. Programmer Response: Ensure that the proper data set name was specified in the job control language DD statement. |
| 16 | Explanation: A GDG entry was found to be deleted from a
catalog. Programmer Response: Ensure that the proper data set name was specified in the job control language DD statement. |
| 18 | Explanation: A GDG type of locate request specified an
incorrect generation number. Programmer Response: Ensure that the proper data set name was specified in the job control language DD statement. |
| 20 | Explanation: The volume entry being removed from an catalog
entry during ALTER REMOVEVOLUMES processing cannot be found in the catalog record or the volume
being removed is a PRIME volume. Programmer Response: Verify that the volume serial numbers specified actually exist in the catalog entry for the data set being altered and is not a PRIME volume. |
| 38 | Explanation:
A duplicate entry name or high level index name was found in the target
catalog during a define command. See section on Multi Level Alias Facility in your "Managing
Catalogs" manual. Programmer Response: In the DEFINE command, specify a name that does not already exist in the target catalog. In the case of a DEFINE ALIAS, make sure there are no data sets that currently exist with that same high-level qualifier. |
| 40 | Explanation: A DEFINE GDG command was not issued before the
DEFINE NONVSAM command with GDG entry name. Programmer Response: Ensure that the GDG base is defined before defining the non-VSAM with a GDG entry name. |
| 42 | Explanation: The catalog record for the requested entry
could not be found. Programmer Response: Ensure that the entry name specified on the access method services command is in the catalog specified. |
| 44 | Explanation: A request to place a record by key into an ICF
catalog resulted in a duplicate key error from VSAM. Programmer Response: If the spelling and catalog being used are correct, run the DIAGNOSE command to analyze the catalog. |
| 46 | Explanation: A base record was not found upon deletion of a
cluster, AIX® or GDG in an ICF catalog. Programmer Response: Run the DIAGNOSE command to analyze the catalog. The ICF catalog may have to be restored or rebuilt. |
| 50 | Explanation: A record was not found during LISTCAT ALL
processing. Programmer Response: The requested record may have been moved during concurrent catalog updating. Ignore the error or run the job again. |
| 52 | Explanation: A duplicate data component name was found.
Programmer Response: Ensure that all data component names are unique and run the job again. |
| 54 | Explanation: A duplicate index component name was found.
Programmer Response: Ensure that all index component names are unique and run the job again. |
| 56 | Explanation: An IDCAMS ALTER REMOVEVOLUMES command was issued against a
Guaranteed Space candidate volume. Programmer Response: Ensure that the volume or volumes are not Guaranteed Space candidate volumes and then run the job again. |
| Reason Code | Description |
|---|---|
| x | Explanation: A record being processed contained inconsistent
or incorrect data for the type of entry. Programmer Response: Run the DIAGNOSE command to check for a damaged catalog record. A SYS1.DUMP may have been produced for this error. |
| 0 | Explanation: An incorrect record type is found when trying
to find a subrecord to be moved. Programmer Response: Run the DIAGNOSE command to check for a damaged catalog record. |
| 10 | Explanation: An incorrect VSAM volume record was read from
the VSAM volume data set and was detected while modifying the catalog's VSAM volume record.
Programmer Response: Perform the following steps:
|
| 12 | Explanation: The record type for a data set was found to be
incorrect during reset of a reusable data set. Programmer Response: Ensure that the target of a reset is a VSAM data set. Call your programming support personnel. |
| 14 | Explanation: On a disconnect request, the connector record
was missing or incorrect. Programmer Response: Run the DIAGNOSE command to determine if the user catalog connector record is damaged and take the recommended action. |
| 16 | Explanation: A GDG Extended record was found on a system
before V2R2. Programmer Response: None. Use of GDG Extended is not valid for this level of the system. |
| 20 | Explanation: The volume cell in the VVDS catalog record
could not be found. Programmer Response: Run the DIAGNOSE command to determine if the VVDS catalog record is damaged and take the recommended action. |
| 42 | Explanation: A VVDS record contained inconsistent data.
Programmer Response: Run the DIAGNOSE command to check for a damaged VVDS record. |
| 50 | Explanation: VVR or NVR exceeds its maximum size. |
| Reason Code | Description |
|---|---|
| x | Explanation: A required component was not found within a
catalog record. Programmer Response: Run the DIAGNOSE command to check for a damaged catalog record. A SYS1.DUMP may have been produced for this error. |
| Reason Code | Description |
|---|---|
| x | Explanation: A required cell was not found in a catalog
record during processing. Programmer Response: Run the access method services DIAGNOSE command to check for a damaged catalog record. A SYS1.DUMP may have been created. |
| Reason Code | Description |
|---|---|
| x | Explanation: An attempt was made to issue an ALTER command
to remove SMS volumes. Programmer Response: Do not attempt the incorrect ALTER command. Correct the commands and rerun the job. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: A system request to alter the backup-while-open
(BWO) options specified an inconsistent or unsupported state. Programmer Response: This is most likely an invalid catalog parameter list. Contact the IBM Support Center. |
| 2 | Explanation: An attempt to alter a data set's storage class
name or management class name has fail because DFSMShsm was not active. The system found incorrect data for an alter of a
backup while the backup was open. Programmer Response: Verify DFSMShsm is operational and retry the request. |
| 4-10 | Explanation: An ALTER for a migrated data set was issued,
but the call to DFSMShsm failed. The
reason-code code is from DFSMShsm. Programmer Response: Refer to DFSMShsm message ARC0073I in z/OS MVS System Messages, Vol 2 (ARC-ASA) for an explanation of the reason code and take the appropriate action. |
| 12 | Explanation: An attempt to alter a data set's security
information was rejected. Security information is no longer supported in catalogs. Programmer Response: Remove the security-related parameters (READPW, UPDATEPW, MASTERPW, CONTROLPW, ATTEMPTS, CODE, AUTHORIZATION) and retry the alter request. |
| 14 | Explanation: An ALTER command failed to rename a data set into a
generation data group, because the data set has ACCOUNT information associated with it.
Programmer Response: Copy the data set to a new NonVSAM data set to remove the ACCOUNT information. Then rename the new data set into the generation data group. |
| 16 | Explanation: An ALTER of a VSAM data set with an indirect volume serial
is not supported. Programmer Response: Ensure that the data set is not a VSAM data set with an indirect volume serial, and rerun the ALTER. |
| 98 | Explanation: An ALTER for a migrated data set was issued,
but the call to DFSMShsm failed. The
reason-code code is from DFSMShsm. Programmer Response: Refer to DFSMShsm message ARC0073I in z/OS MVS System Messages, Vol 2 (ARC-ASA) for an explanation of the reason code and take the appropriate action. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The catalog cannot be extended for one of the
following reasons:
Programmer Response: Scratch unneeded data sets from the volume. Delete all unnecessary entries from the catalog. The catalog may need to be reallocated and rebuilt if these steps do not resolve the space shortage. |
| Reason Code | Description |
|---|---|
| x | Explanation: An invalid structure was passed as input to a
catalog request. Programmer Response: Contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An I/O error occurred while attempting to read
information from the catalog. Programmer Response: Messages IEC331I, IEC332I, and IEC333I have been printed to aid in determining the cause of the error and where the error occurred. If a hardware error is not causing the problem, restore or rebuild the catalog. |
| Reason Code | Description |
|---|---|
| x | Explanation: A VS record management error occurred while
processing a catalog request. Programmer Response: Contact the IBM Support Center. An SVC dump is created for this error. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An I/O error processing the catalog occurred
while processing an access method services command that requires modifying the catalog.
Programmer Response: Messages IEC331I, IEC332I, and IEC333I have been printed to aid in determining the cause of the error and where the error occurred. If a hardware error is not causing the problem, restore or rebuild the catalog. |
| 4 | Explanation: An I/O error occurred during catalog OPEN.
Programmer Response: Messages IEC331I, IEC332I, and IEC333I have been printed to aid in determining the cause of the error and where the error occurred. If a hardware error is not causing the problem, restore or rebuild the catalog. |
| 6 | Explanation: One or more entries were not deleted due to an
I/O related error during DELETE processing. Programmer Response: Messages IEC331I, IEC332I, and IEC333I have been printed to aid in determining the cause of the error and where the error occurred. If a hardware error is not causing the problem, restore or rebuild the catalog. |
| 26 | Explanation: An I/O error occurred while writing the
catalog's self-describing records. Programmer Response: Contact the IBM Support Center. |
| 28 | Explanation: A close error occurred after the writing of the
catalog's self-describing records. Programmer Response: Contact the IBM Support Center. |
| 30 | Explanation: An I/O error occurred writing records to the
catalog. Programmer Response: Contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has
occurred. Programmer Response: Contact the IBM Support Center. An SVC dump may be created for this error, depending on the specific reason code. |
| 6 | Explanation: Attempt to define an alias that relates to a
volume category. Programmer Response: This is an incorrect function. Possible user error. |
| 18 | Explanation: The required library name was not specified for
a define library request. Programmer Response: Supply a library name and rerun the job. |
| 20 | Explanation: Required library ID was not specified for a
define library request. Programmer Response: Supply a library ID and rerun the job. |
| 22 | Explanation: The library logical type specified is incorrect
for a define library record request. Programmer Response: Supply a valid library logic type and rerun the job. |
| 34 | Explanation: Incorrect name was specified for a define
volume category request. Programmer Response: The volume category's name must begin with SYS1.VOLCAT.V. |
| 40 | Explanation: Incorrect checkpoint indicator was specified
for a define volume request. Programmer Response: Supply a valid checkpoint indicator and rerun the job. |
| 42 | Explanation: Incorrect volume location was specified for a
define volume request. Programmer Response: Supply a valid volume location and rerun the job. |
| 44 | Explanation: Required library name not specified for a
define volume request with a volume location of library specified. Programmer Response: Supply a library name and rerun the job. |
| 46 | Explanation: Incorrect volume use attribute specified for a
define volume request. Programmer Response: Supply a valid use attribute and rerun the job. |
| 48 | Explanation: Required volume name not specified for a define
volume request. Programmer Response: Supply a volume name and rerun the job. |
| 50 | Explanation: Incorrect date format specified.
Programmer Response: Re-specify the date in the following format: YYYY-MM-DD. |
| 56 | Explanation: Attempt to alter the number of scratch volume
message thresholds for an incorrect media type. Programmer Response: Supply a valid media type and rerun the job. |
| 58 | Explanation: Attempt to alter the number of scratch volumes
for an incorrect media type. Programmer Response: Supply a valid media type and rerun the job. |
| 62 | Explanation: No general volume category was found.
Programmer Response: Define SYS1.VOLCAT.VGENERAL then rerun the job. |
| 66 | Explanation: An attempt was made to create a volume or library record
into a non-volume catalog. Programmer Response: Ensure the high-level qualifier of the volume or library record matches the high-level qualifier of the volume catalog. |
| 68 | Explanation: Non-volume category was specified for a request
associated with volume or library record. Programmer Response: Ensure SYS1.VOLCAT.VGENERAL is a volume category for library requests. For volume entry requests, check all catalogs with volume category naming convention to be volume categories. |
| 70 | Explanation: A duplicate entry name was found during define
library or volume request. Programmer Response: Remove the duplicate entry and rerun the job. |
| 72 | Explanation: General volume category had been deleted or
disconnected. Programmer Response: Redefine or reconnect general volume category. |
| 98 | Explanation: Incorrect library name specified for a define
library request. The library name cannot begin with ‘V’. Programmer Response: Supply a valid library name and rerun the job. |
| 154 | Explanation: Attempting to delete a library record which is
not empty, or scratch volumes is not equal to zero. Programmer Response: Verify the library record tried to delete. If the library record is empty and the scratch volumes count equal to zero then contact the IBM Support Center |
| 158 | Explanation: Attempting to delete a volume record that has
not reached its expiration date. Programmer Response: Verify the expiration date. ALTER command may be used to alter the expiration date. |
| 168 | Explanation: Attempting to delete a record without
specifying the correct type in catalog parameter list. Programmer Response: Specify the type and rerun the job. |
| Reason Code | Description |
|---|---|
| x | Explanation: The length of the catalog work area specified
is either zero or too small. Programmer Response: If using the CSI, use the value returned in CSIREQLN for the workarea length and try again. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An incorrect record type was found in the
access method services ALTER command. Programmer Response: Determine if the correct name was specified in the command or if the proper fields are requested to be modified for the entry type. |
| 4 | Explanation: A data set name was not found on the VTOC.
Programmer Response: Ensure that the proper versions of the volume and catalog are being processed and that the volume is synchronized with the catalog, or ensure that the VVR/NVR entry type in the VVDS matches its corresponding format 1 DSCB record type from the VTOC. |
| 12 | Explanation: A locate request to catalog management requires
dynamic access to a catalog. Programmer Response: If this error causes a job to end, ensure that the master catalog references the proper catalogs and that they are available to the system when the job stream is processed. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An error was encountered while attempting to
recall a data set with a volume serial of MIGRAT. The catalog entry indicated that the data set was
migrated, but DFSMShsm determined that the data set was not migrated. Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. |
| 4 | Explanation: An error was encountered while attempting to
recall a data set with a volume serial of MIGRAT (the catalog entry indicated that the data set was
migrated). Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. |
| 8 | Explanation: An error was encountered while attempting to
delete a data set with a volume serial of MIGRAT (the catalog entry indicated that the data set was
migrated). Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. Check if an attempt to delete a data set in an alternate catalog occurred, while a duplicately migrated data set exists in a catalog that can be found in the standard search order (through the master catalog). If so, recall the migrated data set and reissue the delete. |
| 12 | Explanation: The catalog installation exit module issued a
locate request, and catalog indicated that the request was not successful. Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. |
| 16 | Explanation: The catalog installation exit module was
processing a JES3 converter/interpreter (C/I) request for a data set with a volume serial of MIGRAT
(the catalog entry indicated that the data set was migrated). The exit module determined that
DFSMShsm was not ready to process the JES3 C/I request because of one of the following reasons:
Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. The DFSMShsm message was issued through a TPUT request to the user ID specified on the job that requested this function. In other words, the message was not routed to the job log. |
| 24 | Explanation: The catalog installation exit module was
processing a JES3 (C/I) request for a data set, and determined that the request was from an
unauthorized user. Programmer Response: Review the DFSMShsm message or messages and take the appropriate action. The DFSMShsm message was issued through a TPUT request to the user ID specified on the job that requested this function. In other words, the message was not routed to the job log. |
| 48 | Explanation: The referenced data set is in an incomplete
status. Programmer Response: Recall the data set and then issue your request again. |
| 50 | Explanation: DFSMShsm generates this reason code when the
installation is using the DFSMShsm patch to prevent interactive TSO users from being placed in a
wait state while a data set is recalled. This code is generated to cause the locate to fail instead
of placing the TSO session in a wait state and may be ignored. The recall for the data set has been
scheduled and the function causing the recall should be tried again later. Programmer Response: Submit the requested function again. |
| 52 | Explanation: For TSO HSM RECALL requests, the RECALL request has been
converted to a background request when the attention key is used and message ARC1020I is replied to
with 'Y'. Programmer Response: Information only. No action is required. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The user provided work area is too small.
Programmer Response: Run the job again with a work area length that is at least equal to the required length. |
| 2 | Explanation: The format 1 work area is too small.
Programmer Response: Run the job again with a work area length that is at least equal to the required length. |
| 8 | Explanation: The volume list is too small to include the storage management subsystem workarea. |
| 12 | Explanation: The architectural limit for a locate function
has been exceeded. The amount of data cannot be returned to the caller. Programmer Response: If you are supplying a filter for the entries to be returned, try a more specific filter and rerun. |
For details about how to address the errors
indicated by the following reason codes, see z/OS DFSMSdfp Diagnosis, Chapter 6 DADSM/CVAF Diagnostic Aids, and refer to the
section about DADSM return and diagnostic codes
.
| Reason Code | Description |
|---|---|
| 2 | Explanation: A DADSM RENAME error occurred on branch entry. |
| 4 | Explanation: A DADSM ALLOCATE error occurred on branch entry. |
| 6 | Explanation: A DADSM SCRATCH error occurred on branch entry. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: The delete catalog work area is too small.
Programmer Response: Check the work area length. If it is correct, contact the IBM Support Center. If the length is not correct, run the job again with a valid length. |
| 4 | Explanation: The caller's work area is too small.
Programmer Response: If this is a Catalog Search Interface (CSI) request, you need to increase the size of the work area. Otherwise, this may be a logic error or limitation in the component making the request. |
| 6 | Explanation: An access method services DELETE command to
delete an entire generation data group, with the FORCE parameter, encountered a work area too small
to contain names of entries deleted. However, the entire GDG was successfully deleted. The following
then occurs:
Programmer Response: Run the job again with a larger work area. |
| 8 | Explanation: The caller's work area is too small.
Programmer Response: If this is a Catalog Search Interface (CSI) request, you need to increase the size of the work area. Otherwise, this may be a logic error or limitation in the component making the request. |
| 12 | Explanation: The amount of data that the system will return
may overflow the workarea. Programmer Response: Either divide the catalog into smaller catalogs or convert to the ICF catalog format. |
| 14 | Explanation: The amount of data returned by the system
cannot be contained in a 2-byte length field. Programmer Response: None. This is a design limitation. If you are using the CSI (Catalog Search Interface), you must request that fullword lengths be used for all lengths. |
| Reason Code | Description |
|---|---|
| 1 | Explanation: UCBPIN PIN returned an unexpected return
code. Programmer Response: Contact the IBM Service Center. An SVC dump might have been produced for this error. |
| 2 | Explanation: UCBPIN UNPIN returned an unexpected return
code. Programmer Response: Contact the IBM Service Center. An SVC dump might have been produced for this error. |
| 4 | Explanation: Catalog VVDS has not operated on the specified
volume since IPL. Programmer Response: None. Message is informational only. |
| 5 | Explanation: Catalog VVDS has not operated on the specified
volume under the currently running instance of Catalog. Programmer Response: None. Message is informational only. |
| 6 | Explanation: Catalog VVDS does not have the specified volume
PINNED for operation. Programmer Response: None. Message is informational only. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: VSAM has detected an internal error while
processing a catalog index. Programmer Response: Rerun the request. If the error continues,
see z/OS DFSMSdfp Diagnosis,
under VSAM Diagnostic Aids, in the section for |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has occurred.
Programmer Response: Contact the IBM Support Center. |
| 6 | Explanation: An ALTER of a non-VSAM entry is not allowed for
the fields being modified. Programmer Response: Ensure that the proper entry name was specified on the access method services ALTER command and that only fields that exist for a non-VSAM entry are requested to be changed. |
| 8 | Explanation: An ALTER of the catalog name is not allowed.
Programmer Response: Ensure that the catalog name was not used by mistake. Catalog names can only be changed by DELETE and then re-DEFINE catalog commands. |
| 10 | Explanation: Erase option delete, but file name is for
incorrect catalog. Programmer Response: Do not use a DD name on the catalog parameter in the access method services DELETE command if erase processing is to be performed. |
| 14 | Explanation: A data set is update inhibited.
Programmer Response: Do not open a data set for reset processing that is inhibited for update processing. |
| 16 | Explanation: A data set is not reusable. Programmer Response: Do not open a non-empty data set for reset processing that is not reusable. |
| 18 | Explanation: It is only valid to change the attributes or
owner id fields of a GDG base entry by the access method services ALTER command. Programmer Response: Do not attempt the incorrect ALTER commands. Correct the commands and rerun the job. |
| 24 | Explanation: It is not valid to attempt to change the name
of a user catalog or alias entry through the use of the access method services ALTER Command.
Programmer Response: Do not attempt the incorrect ALTER commands. Correct the commands and rerun the job. |
| 26 | Explanation: It is not valid to attempt to change the name
of a non-VSAM entry that is a GDG base or member through the use of the access method services ALTER
command. Programmer Response: Do not attempt the incorrect ALTER commands. Correct the commands and rerun the job. |
| 28 | Explanation: It is not valid to attempt to delete a GDG base
entry that contains non-VSAM entries. Programmer Response: Delete the members of the GDG base explicitly. Alternatively, the GDG base and its members may be deleted with the use of the FORCE parameter in the DELETE command. |
| 29 | Explanation: RBA too large for data set. |
| 30 | Explanation: It is not valid to delete the master catalog
with the FORCE parameter. Programmer Response: The master catalog cannot be deleted. Submit the job again. |
| 36 | Explanation: The ALTER REMOVEVOLUMES volume cleanup function
contains incorrect coded parameters. Programmer Response: Only the master catalog name, password, and file parameters may be coded for the ALTER REMOVEVOLUMES function. |
| 40 | Explanation: An incorrect catalog management function, ALTER
of a VVDS name, occurred. Programmer Response: Do not attempt the incorrect ALTER commands. Correct the commands. Run the job again. |
| 42 | Explanation: The maximum number of extensions was exceeded.
Programmer Response: Redefine the catalog with a RECORDSIZE specifying a maximum of 32400. |
| 54 | Explanation: An incorrect reset of a non-reusable data set
was detected. Programmer Response: Do not open a non-empty data set for reset processing that is not reusable. |
| 56 | Explanation: The data set update is inhibited.
Programmer Response: Do not open a data set for reset processing that is inhibited for update processing. |
| 60 | Explanation: A define no-allocate or RECATALOG was not APF
authorized. Programmer Response: Probable user error. Ensure that access method services is APF authorized. |
| 64 | Explanation: A DEFINE of a SYS1.VVDS.Vvolser cannot request
space in records. Programmer Response: Change records to tracks or cylinders. Run the DEFINE command again. |
| 70 | Explanation: An ALTER LOCK of the master catalog is not allowed. |
| 72 | Explanation: An incorrect catalog management function alter of a non-VSAM data set name that is cataloged with an indirect volser occurred. |
| 74 | Explanation: An alter newname of a tape data set is
incorrect. Programmer Response: Do not attempt the incorrect ALTER commands. Correct the commands. Run the job again. |
| 76 | Explanation: An alter of non-VSAM data set that contains the
extended format cell is not allowed. Programmer Response: None. |
| 78 | Explanation: The conversion of SMS to non-SMS managed cannot be done for a data set that contains the extended format cell. |
| 80 | Explanation: Define data set with extended format information is not valid for a non-SMS data set. |
| 82 | Explanation: Unable to define an encrypted data set because
the data set is not an extended format or a zFS. Programmer Response: Select an extended format data set or specify the ZFS keyword. Rerun the job. |
| 84 | Explanation:The key label name is not valid. The name does
not follow the rules for naming key labels as supported by ICSF. Refer to z/OS Cryptographic Services ICSF TKE Workstation User's Guide for general rules for creating
key labels. Programmer Response: Correct the key label name. Rerun the job. |
| 86 | Explanation: The device type is incompatible with
encryption. Programmer Response: Specify a volume with device a type of 3390. |
| 90 | Explanation: Re-cataloging a temporary VSAM data set is not allowed. |
| 94 | Explanation: The conversion of SMS to non-SMS managed cannot be done for a data set that contains attributes extension information. |
| 96 | Explanation: Define data set with attributes extension information is not valid for a non-SMS data set. |
| 98 | Explanation: A define of non-extended data set that contains
compress information is not allowed. Programmer Response: None |
| 102 | Explanation: The request is against an SMS-managed data set, but the specified data set is not SMS managed. |
| 104 | Explanation: The user is not authorized to issue ALTER no VVDS update. |
| 108 | Explanation: The specified SMS construct cannot be altered. |
| 112 | Explanation: A VSAM data set cannot be converted to an SMS managed data set because not all of its components' names resolve to the same catalog. |
| 118 | Explanation: A SMS storage class construct cannot be blanks. |
| 120 | Explanation: The ALTER NEWNAME is not allowed for non-VSAM data set with an alias when the new name resolves to a different catalog than the current one. |
| 122 | Explanation: The ALTER NEWNAME is not allowed for VSAM data set when the new name resolves to a different catalog than the current one. |
| 124 | Explanation: A VSAM data set cannot be converted to SMS managed because not all of the volumes belong to the same storage group. |
| 126 | Explanation: A VSAM data set cannot be converted to SMS managed because not all of its associated names in the sphere resolve to the same catalog. |
| 128 | Explanation: An SMS storage class construct cannot have a length of zero. |
| 130 | Explanation: Altering a non-SMS managed VSAM data set to an SMS managed one (or vice versa) is a stand-alone function. No other ALTER functions are allowed. |
| 132 | Explanation: Altering a non-specific volume serial to a specific one is a stand-alone function. No other ALTER functions are allowed. |
| 134 | Explanation: The user is not authorized to alter a non-specific volume or the user attempted to alter a non-SMS managed data set to include non-specific volser. |
| 136 | Explanation: An incorrect component was supplied for ALTER non-specific volume. |
| 140 | Explanation: An ALTER GDG limit of 0 is not allowed. |
| 142 | Explanation: An ALTER fails due to unsuccessful DADSM UPDATE function. |
| 144 | Explanation: A Record unit of allocation not valid for linear data sets. |
| 146 | Explanation: The ALTER NONVSAM RECATALOG function and the caller pass SMS information for conversion, but the caller is not authorized to use this function. |
| 148 | Explanation: Alter request is not valid for stand-alone
function such as alter of backup while open (BWO) data set. Programmer Response: Ensure that the field requested to be altered is valid for stand-alone function. |
| 152 | Explanation: An attempt has been made to define a PDSE as a
member of a GDG base. PDSEs may not be a member of a GDG base Programmer Response: Be sure that the IGDSMS00 parmlib member has DSNTYPE default of PDS. |
| 156 | Explanation: The alter backup while open (BWO) request is
not for valid component or record. Programmer Response: Ensure that the BWO alter request is for cluster, data, non-VSAM, or GDS only. |
| 158 | Explanation: The alter backup while open (BWO) indicator is
incorrect for non-SMS managed data sets Programmer Response: Ensure that the data set is SMS-managed. |
| 160 | Explanation: An attempt was made to alter a non-SMS managed
non-VSAM data set to a name in the format of a GDS (for example, the name ends with GnnnnVnn).
Programmer Response: Change the name of the new data set to be a non-GDS format name. |
| 162 | Explanation: An attempt was made to alter a non-SMS managed GDS to a non-GDS name. |
| 166 | Explanation: An alter volume or device type on OAM entries
is not allowed. Programmer Response: None |
| 168 | Explanation: An attempt was made to alter an SMS-managed
non-VSAM data set to a GDS name (for example, the name ends with GnnnnVnn), but there is no GDG base
associated with the new name. Programmer Response: Change the name of the new data set to one that has an existing GDG base definition. |
| 170 | Explanation: When defining an OAM data set, a generation
data set low level qualifier (that is, G0000V00) or an increment of a GDG number (that is, +1) is
invalid. Programmer Response: Use a name other than the GDS low level qualifier or a GDG increment number. Rerun the define request. |
| 172 | Explanation: REUSE was specified for a non-cluster component or a component that had an AIX Associated with it. |
| 174 | Explanation: ALTER REUSE was specified for a cluster that has an AIX defined over it. |
| 175 | Explanation: A DEFINE of a striped data set specified REUSE, which is invalid. |
| 176 | Explanation: ALTER REUSE was specified for a cluster that contains a KEYRANGE. |
| 178 | Explanation: ALTER-REUSE-ON and ALTER-REUSE-OFF are mutually
exclusive. They cannot be active at the same time. Programmer Response: Only one ALTER-REUSE bit should be set at a time. |
| 184 | Explanation: Attempted to ALTER the DDM file class attribute for other than a CLUSTER or NONVSAM entry. |
| 186 | Explanation: Attempted to ALTER the pointer to the last active record for other than CLUSTER or NONVSAM entry. |
| 188 | Explanation: Attempted to ALTER DFM attributes for a non-SMS data set. |
| 190 | Explanation: Attempted to ALTER DFM attributes for other than a CLUSTER entry. |
| 192 | Explanation: Attempted to ALTER DFM attributes for other than a CLUSTER or NONVSAM entry. |
| 194 | Explanation: A specific request to locate an OAM data set
was made and a data set was found, but it is not an OAM data set name. Programmer Response: Verify that the name of the data set wanted is an OAM data set. |
| 196 | Explanation: A specific request to locate an OAM data set
was made and a data set was found, but it is not an OAM data set name. Programmer Response: Verify that the name of the data set wanted is an OAM data set. |
| 200 | Explanation: The ALTER ADDVOL function cannot be used to
cause the number of volumes of a SMS-managed data set to exceed the maximum of 59 volumes.
Programmer Response: The maximum allowable volumes for a SMS-managed data set are 59. If this error was issued incorrectly, contact the IBM Support Center. |
| 202 | Explanation: A request to re-catalog a temporary non-VSAM
data set is not valid. Programmer Response: Correct the request. If the error recurs, contact the IBM Support Center. |
| 204 | Explanation: HSM-INCOMPLETE-ON and HSM-INCOMPLETE-OFF are
mutually exclusive. They cannot be active at the same time. Programmer Response: Only one HSM-INCOMPLETE bit should be set at a time. |
| 216 | Explanation: Define of ACCOUNT information is invalid for
non-SMS-managed data sets. Programmer Response: Ensure that the data set is SMS- managed and then rerun the request. |
| 218 | Explanation: Alter of ACCOUNT information is invalid for
non-SMS-managed data sets. Programmer Response: Ensure that the data set is SMS-managed and then rerun the request. |
| 222 | Explanation: Extended attribute (AX) cell and ACCOUNT
information are mutually exclusive for define or alter request. Programmer Response: Ensure that the AX cell and ACCOUNT information are not both specified during define or alter of the data set. |
| 226 | Explanation: Multivolume DEFINE RECATALOG of a data set with
an indirect volser is not supported. Programmer Response: Ensure that the VOLUME parameter for the DEFINE RECATALOG has only one indirect volume serial specified before attempting the DEFINED RECATALOG. |
| 228 | Explanation: An alter of a non-EA SMS-managed VSAM LDS to
Extended Addressable is not allowed. Only valid data set type is a non-SMS managed VSAM
LDS. Programmer Response: Ensure that the data set on the ALTER EXTENDEDADDRESSABLE command is a non-SMS managed VSAM LDS and re-issue the request. If the problem persists, contact the IBM support center with the job output and/or dump. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has occurred, or an
error has been detected in the structure or contents of a VVDS. Programmer Response: Run a DIAGNOSE and print the VVDS associated with the problem. These errors will usually be accompanied by additional console messages which contain SFI information necessary to diagnose the problem. Contact the IBM Support Center. |
| 2 | Explanation: New catalog name added. This is a normal return
code returned during the adding of a new VVR. The associated catalog name of the VVR was new to the
VVDS and was added to the VVCR/VVCN record. Programmer Response: None |
| 4 | Explanation: VVDS Manager parameter list had incorrect
information. This attention error code does not effect the operation of the request.
Programmer Response: Contact the IBM Support Center. |
| 5 | Explanation: The VVDS required for LISTCAT could not be
accessed. The missing data in the LISTCAT output will contain Xs. The volume might be offline, but a
mount request is not automatically issued for a LISTCAT operation. If present, the
sfi value is FOR volser, where
volser is the volume serial of the VVDS on which the error was detected.
Programmer Response: Ignore the return code or ensure the volume is online and available for the LISTCAT operation. |
| 6 | Explanation: A requested VVR or NVR was not found in the
VVDS specified. If present in this message, the sfi value is FOR
volser, where volser is the volume serial of the VVDS
on which the error was detected. The sfi value in message IEC331I contains
characters 5 through twelve of the requested VVR name. Programmer Response: Ensure that the volume serial numbers provided in VOLUMES parameters and DD statements are correct. If all the commands are specified correctly, this condition may indicate an error in the catalog or VVDS. Run the DIAGNOSE command to determine if any catalog records are in error. |
| 7 | Explanation: One or more of the 3 required VVRs for a
catalog was not found. sfi in message IEC331I contains the first 8 characters of
the catalog name whose VVR(s) was missing. Programmer Response: Run DIAGNOSE command against the VVDS and correct any problem detected. |
| 8 | Explanation: A DEFINE command for a VVDS has failed because
a VVDS already exists on the volume. No SFI data. Programmer Response: If the existing VVDS is to be replaced, delete it before defining the new VVDS. |
| 9 | Explanation: A dynamic allocation will require a TIOT slot,
but a search finds none available. No SFI data. Programmer Response: Contact the IBM Support Center. |
| 10 | Explanation: Bad return code from dynamic allocation issued
from DFSMS/MVS. SFI contains the SVC 99
reason code. Programmer Response: Ensure that the VVDS name or the volume serial number provided is correct. If an access method services command was being processed, ensure that all required FILE parameters are supplied. Ensure that the volume will be mounted and available by providing a DD statement for the volume. |
| 11 | Explanation: The caller of the VVDS manager passed a volume
serial number in the parameter list and a UCB address. The UCB's volume serial does not match the
parameter list volume serial. The SFI contains the UCB volume serial while the parameter list volume
serial is in the second field in the SFI data. Programmer Response: Contact the IBM Support Center. |
| 12 | Explanation: An attempt to allocate space on a DASD volume
has failed. SFI contains the historical return code from DADSM allocate. Programmer Response: Ensure that there is enough space for the VVDS data set being defined. The data set will require a minimum of three to four tracks. If space was available when the error occurred, contact the IBM Support Center. |
| 13 | Explanation: The VSAM volume data set (VVDS) request
contained an invalid volume serial number (VOLSER). The invalid VOLSER might be available with the
structured field introducers (SFI) information. Programmer Response: Rerun the request with a valid VOLSER. |
| 14 | Explanation: A request to delete a VVDS has failed because
the VVDS still contained VVRs. SFI contains the RBA of the first CI that contains a VVR.
Programmer Response: If the VVDS is to be deleted, first delete the VSAM data sets on the volume and then run the DELETE command again. Or, if the VVDS is to be recovered, run the DELETE command again with the RECOVERY parameter. |
| 16 | Explanation: No storage was available for the VVDS manager
work area. There may be no SFI data because the working storage for the VVDS manager could not be
obtained. Otherwise, SFI will contain the register 15 return code from the GETMAIN request.
Programmer Response: Contact the IBM Support Center. |
| 17 | Explanation: No storage was available for VVDS manager
buffers. SFI contains ‘xxxxzzzz’ where xxxx is the
amount of storage being requested and zzzz is the register 15 return code from
the GETMAIN request. Programmer Response: Increase available LSQA storage. This error can sometimes be avoided by decreasing the region size. |
| 18 | Explanation: An I/O error has been detected while accessing
a VVDS record. This reason code results in message IEC161I being issued, which provides more
information about the error. An SVC dump may also have been created, depending on the type of error
that occurred. Programmer Response: A DIAGNOSE should be run against the VVDS indicated in message IEC161I. If an SVC dump was produced, contact the IBM Support Center. |
| 25 | Explanation: An OBTAIN was issued to read the F1 DSCB for an
existing VVDS and OBTAIN returned with an error. SFI contains the register 15 return code from
OBTAIN. Programmer Response: A failure to obtain a DSCB for a VVR may indicate either a damaged VVDS or the existence of an orphan VVR. In either case, enter the DIAGNOSE command to check the integrity of the VVDS. Correct any errors found as a result of using the DIAGNOSE command. |
| 26 | Explanation: An OBTAIN was issued to read the F1 DSCB for a
new VVDS and OBTAIN returned with an error. SFI contains the register 15 return code from OBTAIN.
Programmer Response: A failure to obtain a DSCB for a VVR may indicate either a damaged VVDS or the existence of an orphan VVR. In either case, enter the DIAGNOSE command to check the integrity of the VVDS. Correct any errors found as a result of using the DIAGNOSE command. |
| 28 | Explanation: A call to VSAM end of volume to extent the VVDS
has failed. SFI contains register 15 return code from end of volume. Programmer Response: There is probably insufficient space on the volume or in the VTOC to extend the VVDS, in which case no more VSAM data sets can be defined on that volume until space is made available to extend the VVDS. If sufficient space is available at the time this error occurs, contact the IBM Support Center. |
| 30 | Explanation: While updating the VVDS, it was found to be
full and needed to extend, but was already at the maximum number of extents (123). There is no SFI
data. Programmer Response: The volume must be recovered from backup after creating a larger VVDS, or unneeded data sets on the volume must be deleted to release space in the VVDS. |
| 32 | Explanation: The VVDS is full (maximum 1048575 CIs). There
is no SFI data. Programmer Response: If a VSAM data set was being defined, use an alternate volume. If a VVDS was being defined, decrease the primary space allocation. |
| 36 | Explanation: A request to write a VVR could not be processed
because the VVR was larger than the max size of a valid VVR. SFI contains the VVR
length. Programmer Response: Run a DIAGNOSE and print the VVDS associated with the problem. These errors will usually be accompanied by additional console messages which contain SFI information necessary to diagnose the problem. Contact the IBM Support Center. |
| 38 | Explanation: A DELETE command with the NOSCRATCH parameter
has been issued for a catalog. The VVR for the catalog was not deleted because the catalog has data
on the volume. SFI contains the RBA of the first CI that has a VVR owned by the catalog.
Programmer Response: Ensure that the correct catalog is being used and that the VVDS is correctly specified. |
| 40 | Explanation: A call to scratch the F1 DSCB from a volume has
failed. SFI contains the return code from the scratch. Programmer Response: It is possible that a user other than the one issuing the delete has an outstanding ENQ on the VVDS. If this is the case, the ENQ should be removed. |
| 42 | Explanation: Write not allowed to a VVDS that resides on a
volume with the read-only attribute. Programmer Response: Contact your System Administartor about the read-only status of the volume. Re-run the request when write access is allowed to the volume. |
| 80 | Explanation: An internal VVDS logic error has occurred. If
the SFI information contains “IORUNING”, the job associated with the catalog request may
have been terminated abnormally (for example, operator CANCEL, TSO attention) and this does not
represent an internal logic error. Programmer Response: If the SFI information contains “IORUNING”, check console and job logs for the associated job to see if it was abnormally terminated. You should run a DIAGNOSE against VVDS on the volume indicated to check for any possible damage. If the SFI information is not “IORUNING”, you should contact IBM Service. |
| 82 | Explanation: The system discovered, during synchronization
processing of the VTOC and VVR extents, that the number of extents indicated for the data set in the
VTOC is more than the number indicated in the VVR. Programmer Response: Print the VVDS and VTOC. Contact the IBM Support Center. |
| 84 | Explanation: The system discovered, during synchronization
processing of the VTOC and VVR extents, that the number of extents indicated for the data set in the
VVR is more than the number indicated in the VTOC. Programmer Response: Print the VVDS and VTOC. Contact the IBM Support Center. |
| 85 | Explanation: During synchronization processing of the VTOC
and VVR extents, the VVDS manager was unable to read the DSCBS. Programmer Response: Print the VVDS and VTOC. Contact the IBM Support Center. |
| 86 | Explanation: The VVR for the VVDS number of extents field is
not valid; it has more than 123 extents in it. SFI contains the VVR's extent number.
Programmer Response: Print the VVDS. Contact the IBM Support Center. |
| 87 | Explanation: During open processing of a VSAM data set, the
system discovered that there were fewer extents in the VTOC than were described in the VVDS for the
component, or that the extent ranges did not match between the VVDS and VTOC. System Action: The data set will not be permitted to open. Message IEC331I is issued to detail which volume and component is incorrect. Programmer Response: Use LISTCAT and LISTVTOC to determine the details of the mismatch. The data set must be recreated to correct the error. |
| 88 | Explanation: A VVR or NVR with the correct component name
was found, but the catalog name did not match. On a delete request, the BCS record will be deleted,
but the VVR or NVR and the format 1 DSCB will not be scratched. There is no SFI data.
Programmer Response: No action is required because this code is for information only. |
| 89 | Explanation: During open processing of a VSAM data set, the
system discovered that there were extra extents in the VTOC that are not described in the VVR.
System Action: Message IEC331I is issued to detail which volume and component of the data set has extra extents on the volume. Open processing continues. In most cases, on the next extend of the data set the extra extents will be recognized and incorporated into the data set extents. |
| 92 | Explanation: A request to allocate dynamically the VVDS has
failed. SFI contains the dynamic allocation error reason code returned in the SVC 99 request block,
or text stating why the allocation routine failed. Programmer Response: Determine why the dynamic allocation reason code was returned. |
| 94 | Explanation: A VSAM OPEN request to open the VVDS failed. SFI contains
‘xxrrrrrr’, where rrrrrr=register 15 from the OPEN and xx is ACBERFLG. Programmer Response: Determine why the OPEN reason code was returned. |
| 96 | Explanation: A record read from the VVDS was found to be
invalid. System Action: Message IEC331I will be issued in the job log and will contain the RBA and volume serial of the invalid record. An SVC dump will be created for the problem. Programmer Response: A DIAGNOSE of the VVDS should be performed and any errors related to the VVDS corrected. If no errors are detected, contact IBM Service and provide the SVC dump for analysis. |
| 100 | Explanation: A F1 DSCB with a SYS1.VVDS.Vxxxxxx was found
and it is not a VSAM data set. A VVDS cannot be created or opened for this volume. Programmer Response: Determine the source of the non-VSAM data set and have it renamed or removed. |
| 126 | Explanation: VVDS detected a potential problem with VVDS internal
structure. When attempting to correct problem a free control interval (CI) could not be found, which
was required for the repair operation. An SVC dump should have occurred. Programmer Response: Run a DIAGNOSE and print the VVDS associated with the problem. Contact IBM Service and provide the SVC dump plus the DIAGNOSE and print of the problem VVDS. |
| 128 | Explanation: A VVDS request (add, insert, or delete) took very long to
complete. Programmer Response: Please provide any dumps to IBM support. |
| Reason Code | Description |
|---|---|
| x | Explanation: The reason codes associated with this error are
from one of the following:
|
| Reason Code | Description |
|---|---|
| 2 | Explanation: The system attempted to verify alter authority
to the master catalog (update authority for an ALTER NEWNAME), but the user did not have the
required authority. Programmer Response: Ensure the user has the proper authority to the master catalog. For some types of requests, only the proper data set authority is required, and the master catalog is only checked if they do not have necessary data set authority. Granting the authority to the data set may eliminate this error. |
| 4 | Explanation: A non-system caller has specified request
special authority level checking in the catalog parameter list. Programmer Response: Contact the IBM Support Center if the user written programs are not calling catalog management. |
| 6 | Explanation: The user did not have the required access
authority to the specified entry. Programmer Response: Ensure the user has the proper RACF® authorization for the function being requested. |
| 8 | Explanation: The return code from the RACHECK REQUEST=AUTH
was other than 0, 4, or 8. Programmer Response: Determine the reason for the unexpected RACF return code. |
| 14 | Explanation: An implicit alter of a GDG was denied because
the user did not have the proper authority to the GDG base and the catalog. Programmer Response: Ensure the user has the proper authority for the GDG base. |
| 16 | Explanation: The caller is not authorized for the requested SMS Management Class, SMS Storage Class, or both. |
| 28 | Explanation: An unauthorized caller attempted to define an
SMS data set. Programmer Response: Ensure the caller is APF authorized, or system key or system state. |
| 30 | Explanation: The caller was not authorized to the catalog when defining an SMS data set into the master catalog. |
| 32 | Explanation: The return code from the RACHECK REQUEST=AUTH
was other than 0, 4, or 8 when attempting to verify access to a facility class. Programmer Response: Determine the reason for the unexpected RACF return code. |
| 34 | Explanation: An internal logic error has occurred.
Programmer Response: Contact the IBM Support Center. |
| 36 | Explanation: The caller is not authorized. When no profile exists for functions that require RACF authorization, the caller must be at least APF authorized. |
| 40 | Explanation: RACF options do not permit use or cataloging of uncataloged non-SMS managed data sets. |
| 42 | Explanation: Caller is not authorized to use the specified
volume. Programmer Response: Acquire authority to the specified volume and resubmit the job. |
| 44 | Explanation: Caller is not authorized to update catalog for DEFINE ATL request |
| Reason Code | Description |
|---|---|
| 2 | Explanation: The allocation quantity requested for the data
set resulted in an amount greater than 16,777,215 CYL on the primary space quantity. Programmer Response: Reduce the primary space quantity and rerun the request. |
| 4 | Explanation: The allocation quantity requested for the data
set resulted in an amount greater than 16,777,215 CYL on the secondary space
quantity. Programmer Response: Reduce the secondary space quantity and rerun the request. |
| 6 | Explanation: The striped data set was allocated with a primary space
allocation of more than 16777215 tracks. The maximum primary allocation in tracks that can be
specified on the define is 16777215. Programmer Response: Reduce the primary space allocation and rerun the request. |
| 8 | Explanation: The striped data set was allocated with a secondary space
allocation of more than 16777215 tracks. The maximum secondary allocation in tracks that can be
specified on the define is 16777215. Programmer Response: Reduce the secondary space allocation and rerun the request. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: Probable system error. An incorrect entry type
for an extract operation was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 4 | Explanation: An incorrect entry type (cluster or non-VSAM)
was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 6 | Explanation: An incorrect cluster entry for ALTER of data
set attributes was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 8 | Explanation: An incorrect cluster or index entry for ALTER
of buffer size was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 10 | Explanation: An incorrect entry type (CLUSTER) to ALTER the
FREESPACE or WRITECHECK parameters was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 12 | Explanation: An incorrect entry type (CLUSTER) to ALTER
volumes was detected. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 14 | Explanation: Probable system error. An incorrect catalog
parameter list was supplied in an attempt to add a volume. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 16 | Explanation: An attempt was made to alter an SMS-managed
data set to add or delete volumes from the data set; however, one or more of the volume
specifications were specific volume serial numbers. Programmer Response: Only nonspecific volume serial numbers can be added to or removed from SMS-managed data sets. Correct the specification in the ALTER command and retry it. |
| 18 | Explanation:
A user catalog or a VSAM Volume Data Set (VVDS) was specified in the ALTER REMOVEVOLUMES
command. This is not allowed. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that this is not a user catalog or a VVDS. If the entry is a user catalog or a VVDS, please specify a different entry as those types are not allowed by the ALTER REMOVEVOLUMES command. If the entry is not a user catalog or a VVDS, contact the IBM Support Center. |
| 20 | Explanation: The upgrade set association in the base cluster
data record does not point to an upgrade set record. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 22 | Explanation: The data association in the cluster record does
not point to a data record. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 26 | Explanation: ALTER of EXCEPTIONEXIT was specified, but the
entry is not a data or index component. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 28 | Explanation: ALTER of average RECORDSIZE was specified, but
the entry is not a data or index component. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 30 | Explanation: ALTER of expiration date was specified but the
entry is not a cluster, alternate index, or path. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 32 | Explanation: ALTER of last back-up date was specified, but the component is not a cluster, non-VSAM, or GDS. |
| 34 | Explanation: ALTER of last back-up date was specified, but the data set is non-SMS managed and does not have a last back-up date. |
| 36 | Explanation: An alias entry may only be defined for non-VSAM
or user catalog entries. Programmer Response: Do not attempt an incorrect DEFINE operation. |
| 38 | Explanation: A LOCATE or ALTER was specified for a GDG base,
and entry is not a GDG. Programmer Response: GDGs must have qualified names. Ensure that all levels of qualification are specified for GDG. Submit the job again. |
| 40 | Explanation: An input base record to catalog upgrade
management is not an alternate index, cluster or data type entry. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP 11 option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 42 | Explanation: An input base record to catalog reusable
processing is not a data type entry. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog entry is still valid, by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP 11 option. Contact the IBM Support Center. Otherwise, correct the error. Run the job again. |
| 44 | Explanation: An incorrect entry type was encountered in a
DELETE operation, other than the expected alias entry. Programmer Response: Ensure that the proper entry name was specified and that the catalog reflects the expected structure. It may be necessary to rebuild the catalog. |
| 46 | Explanation: An incorrect entry type was encountered in a
DELETE operation, other than the expected VVR type. Programmer Response: Ensure that the proper entry name was specified. |
| 48 | Explanation: An entry type other than the expected NVR type was encountered in a DELETE operation. |
| 50 | Explanation: An incorrect entry type, other than the
expected BCS type, was encountered in a delete operation. Programmer Response: Ensure that the correct entry type was specified. |
| 52 | Explanation: ALTER of SMS constructs was specified, but the component is not a cluster, non-VSAM, or GDS. |
| 54 | Explanation: Define an Extended Format UCAT is not allowed.
Programmer Response: Define the UCAT as a non-Extended Format data set. |
| 56 | Explanation: ALTER of FILEID or CCSID is not allowed with
other DFM attributes. Programmer Response: Ensure that no other DFM attributes are being altered in the same request. Run the job again. |
| 58 | Explanation: ALTER of CCSID is not allowed for non-SMS
managed data set, or the data component of a catalog. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 60 |
Explanation: ALTER of FILEDATA is not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 62 | Explanation: An attempt has been made to alter DFM
attributes for a non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 64 | Explanation: ALTER of 'DFM/NFSS ACCESS AUTH' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 66 | Explanation: ALTER of 'DFM/NFSS ACCESS TIME' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 70 | Explanation: ALTER of 'DFM/NFSS USERID' field is not allowed
for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 72 | Explanation: ALTER of 'DFM/NFSS GROUPID' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 74 | Explanation: ALTER of 'DFM/NFSS LAST SIZE CHANGE' field is
not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 76 | Explanation: ALTER of 'DFM/NFSS MODIFIED TIME' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 78 | Explanation: ALTER of 'DFM/NFSS ATTR CHNG TIME' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 80 | Explanation: ALTER of 'DFM/NFSS BINARY FILE SIZE' field is
not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 82 | Explanation: ALTER of 'DFM/NFSS LOGICAL RECORD COUNT' field
is not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. |
| 84 | Explanation: ALTER of 'DFM/NFSS CHARS NO PADDING' field is
not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 86 | Explanation: ALTER of 'DFM/NFSS TEXT TIMESTAMP' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 88 | Explanation: ALTER of 'DFM/NFSS ATTRIBUTE EXTENSION FLAGS'
is not allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 90 | Explanation: ALTER of 'DFM/NFSS EXTENSION AREA' field is not
allowed for non-SMS managed data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM or non-VSAM data set. Correct the error. Run the job again. |
| 92 | Explanation: ALTER of the RLS SMS flag is not allowed for a
data set that is not capable of being used by RLS. Data sets that are Linear, non-SMS managed,
keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 94 | Explanation: ALTER of the RLS recovery time stamp (local) is
not allowed for a data set that is not capable of being used by RLS. Data sets that are Linear,
non-SMS managed, keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 96 | Explanation: ALTER of the RLS recovery time stamp (GMT) is
not allowed for a data set that is not capable of being used by RLS. Data sets that are Linear,
non-SMS managed, keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 98 | Explanation: ALTER of the RLS flags is not allowed for a
data set that is not capable of being used by RLS. Data sets that are Linear, non-SMS managed,
keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 100 | Explanation: ALTER of the BWO flag is not allowed for
non-SMS managed data set or a linear data set. Programmer Response: Ensure that the entry being altered is an SMS managed VSAM data set that is not LINEAR. Correct the error. Run the job again. |
| 102 | Explanation: ALTER of 'ACCOUNT INFORMATION' is specified but
the entry type is not Data, non-VSAM, or GDS. Programmer Response: Ensure that the name of the entry specified in the command is correct. Ensure that the catalog is still valid by performing a LISTCAT run. If the reason code indicates a system error, list the catalog using the PRINT command with the DUMP11 option. Contact the IBM Support Center. Otherwise, correct the error and run the job again. |
| 104 | Explanation: Invalid entry type for alter of extended addressability data set. |
| 106 | Explanation: ALTER of the LOGSTREAMID parameter is not
allowed for a data set that is not capable of being used by RLS. Data sets that are Linear, non-SMS
managed, keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 108 | Explanation: ALTER of the LOG parameter is not allowed for a
data set that is not capable of being used by RLS. Data sets that are Linear, non-SMS managed, are
keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 110 | Explanation: ALTER of the FRLOG parameter is not allowed for
a data set that is not capable of being used by RLS. Data sets that are Linear, non-SMS managed, are
keyrange or temporary are not eligible for RLS access. Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| 112 | Explanation: An IDCAMS SHCDS command with either the CFRESET
or CFRESETDS keywords was issued against a data set not capable of being used by RLS. Data sets that
are Linear, non-SMS managed, are keyrange or temporary are not eligible for RLS access.
Programmer Response: Ensure that the entry being altered is eligible for RLS processing. Correct the error. Run the job again. |
| Reason Code | Description |
|---|---|
| x | Explanation: An attempt to extend a striped data set to a
new volume encountered an internal logic error when locating the volume information in the catalog
to be updated. Programmer Response: Contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has occurred.
Programmer Response: Contact the IBM Support Center. |
| 6 | Explanation: The association of a true name record in an ICF
catalog is incorrect. Programmer Response: Use access method services to define the associated base of the true name record. |
| 8 |
Explanation: The association of a true name record is not in the IEASYMxx member, or the SYMBOLICRELATE function did not provide a symbolic item. Programmer Response: Check the IEASYMxx to ensure that the item has a symbolic item, or the SYMBOLICRELATE function does not provide a symbolic item. |
| Reason Code | Description |
|---|---|
| x | Explanation: The reason code listed is the return code from the DADSM function, which may have been a RENAME or a SCRATCH request. |
| Reason Code | Description |
|---|---|
| x | Explanation: The returned DADSM Historic Return Code was
other than 0, 4, 8, or 12. The reason code shown is the DADSM return code. See z/OS DFSMSdfp Diagnosis for an
explanation of the DADSM return and diagnostic codes. Programmer Response: The return code is returned by DADSM. |
| 22, 24 | Explanation: An attempt
to allocate an SMS-managed data set using the Best Fit interface was able to allocate space on all
supplied volumes, but the amount of space allocated was not the total amount required. If the data
set being allocated was not SMS-managed then reason code 20 indicates requested space was not
available; The primary allocation amount must be able to be allocated within 5 extents. For a non
SMS-managed VSAM data set the primary allocation amount must be available on each volume if the data
set is a multivolume data set. Programmer Response: The storage group did not contain sufficient space to allocate the data set. If this was a non SMS-managed data set being allocated, the volume(s) did not have sufficient space for the primary allocation amount. |
| 26 | Explanation: An attempt to allocate an SMS-managed data set
using the Best Fit interface resulted in more than 255 extents for the data set. VSAM data sets are
limited to a maximum of 255 extents. Programmer Response: This is most likely a result of significant fragmentation on the volumes selected. Volume reorganization should be performed, or additional volumes added to the storage group with sufficient contiguous space to allow to the allocate to complete. |
| 28 | Explanation: The volume does not contain enough
track-managed space to allocate the BCS, VVDS or page data set. Programmer Response: Try the request with a different volume. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: An internal logic error has occurred processing
a GDS record. Programmer Response: Contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: Unable to mount user volumes. Programmer Response: Ensure that proper volumes are implicitly or explicitly allocated by the JCL. |
| 8 | Explanation: An error occurred while attempting to mount the
user volume. Examples of possible errors include insufficient virtual storage for workareas or a
time-stamp mismatch problem. Programmer Response: Verify that the volume and the volume information (time stamps) contained in the catalog are at the same level. If the problem is due to insufficient virtual storage, specify a larger region parameter. Run the job again. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The volume cell for a base clusters data or
index component was not found. A DEFINE alternate index command was being processed.
Programmer Response: Run access method services DIAGNOSE command for additional information. The base cluster might need to be deleted with the NOSCRATCH option and redefined with the RECATALOG option. |
| 2 | Explanation: The relate cell was not found in the base
cluster sphere record while a moved subrecord update was in progress. Programmer Response: Run access method services DIAGNOSE command against the catalog and then determine the action to be taken. Delete with the NOSCRATCH parameter. Define with the RECATALOG parameter. |
| 4 | Explanation: An association cell was not found for a path or
alias record while a subrecord move update was in progress. Programmer Response: Run access method services DIAGNOSE command against the catalog and then determine the action to be taken. Delete with the NOSCRATCH parameter. Define with the RECATALOG parameter. |
| 10 | Explanation: The SMS cell was not found in the VVDS entry
for a data set, even though the data set is SMS-managed. Programmer Response: Run access method services DIAGNOSE command against the catalog and then determine the action to be taken. The data set may need to be copied to a new SMS data set and the failing data set deleted. |
| 12 | Explanation: The SMS cell was not found in the BCS entry for
a data set, even though the data set is SMS-managed. Programmer Response: Run access method services DIAGNOSE command against the catalog and then determine the action to be taken. The catalog may be repaired by doing a DELETE NOSCRATCH, followed by DEFINE RECATALOG. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: Access method services ALTER name change of a
unique object was specified, but no volumes containing any part of the data set were mounted.
Programmer Response: Ensure that JCL statements cause the proper volumes and units to be allocated. Also, ensure that all DDNAMES specified match the access method services dname parameter when specified. Determine a minimum unit count and have sufficient units available for job processing. Ensure that volumes are allocatable by the use of dynamic allocation. |
| 2 | Explanation: The volume was not mounted when expected.
Programmer Response: Ensure that JCL statements cause the proper volumes and units to be allocated. Also, ensure that all DDNAMES specified match the access method services dname parameter when specified. Determine a minimum unit count and have sufficient units available for job processing. Ensure that volumes are allocatable by the use of dynamic allocation. |
| 8 | Explanation: A scan of the task I/O table (TIOT) failed to
find a needed JCL DD statement. Programmer Response: Ensure that you have all needed JCL DD statements and that all JCL statements cause the proper volumes and units to be allocated. Also, ensure that all DDNAMES specified match the access method services dname parameter when specified. Determine a minimum unit count and have sufficient units available for job processing. Ensure that volumes are allocatable by the use of dynamic allocation. For a non-VSAM data set, ensure the number of volumes on the DD statement match the number of volumes where the data set resides. On a delete request, the BCS record is deleted, but the VVR or NVR and the format 1 DSCB is not scratched. There is no SFI data. |
| 10 | Explanation: A scan of the task I/O table (TIOT) failed to
find the user specified JCL ddname statement. Programmer Response: Ensure that JCL statements cause the proper volumes and units to be allocated. Also, ensure that all DDNAMES specified match the access method services dname parameter when specified. Determine a minimum unit count and have sufficient units available for job processing. Ensure that volumes are allocatable by the use of dynamic allocation. |
| 12 | Explanation: A scan of the task I/O table (TIOT) failed to
find the user specified JCL ddname statement. Programmer Response: Ensure that JCL statements cause the proper volumes and units to be allocated. Also, ensure that all dynamis specified match the access method services dname parameter when specified. Determine a minimum unit count and have sufficient units available for job processing. Ensure that volumes are allocatable by the use of dynamic allocation. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error occurred while
processing a subrecord. Programmer Response: Contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error occurred.
Programmer Response: Contact the IBM Support Center. |
| 0 | Explanation: The related object is reusable.
Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 2 | Explanation: The related object is a relative-record data
set or a linear data set. Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 4 | Explanation: The related object does not exist.
Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 6 | Explanation: An alternate index or path is not allowed to be
built over a catalog. Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 8 | Explanation: The names of an alternate index or path and a
related object are identical. Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 10 | Explanation: There is no pointer to a related object of an
alternate index or path. Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 12 | Explanation: An alternate index is not to be built over a
base cluster, or the related path object is not a cluster or an alternate index. Programmer Response: Correct the DEFINE command so that the entry named in the RELATE parameter is proper for the type of object being defined. |
| 14 | Explanation: A DEFINE PATH command specified a PATHENTRY
name of a PAGESPACE object. Programmer Response: Correct the path entry name. Run the DEFINE PATH command again. |
| 16 | Explanation: A DEFINE PATH command has specified a PATHENTRY
name for a VVDS. Programmer Response: Correct the path entry name. Run the DEFINE PATH command again. |
| 20 | Explanation: The related object for a DEFINE ALTERNATEINDEX
is a VVDS. Programmer Response: Correct the related name. Run the DEFINE AIX command again. |
| 28 | Explanation: The related name specified for a DEFINE ALIAS
command is for a record type other than NONVSAM or USERCATALOG. Programmer Response: Ensure that the related name is correct and that a DEFINE ALIAS command is wanted. If the above is true refer to access method services DIAGNOSE command to obtain additional information. |
| 30 | Explanation: The version number of the related generation data set name
does not match the version number in the base GDG. The DEFINE ALIAS fails. Programmer Response: Correct the version number in the GnnnnVnn part of the generation data set name. Run the DEFINE ALIAS command again. |
| 36 | Explanation: An AIX (alternate
index) data set specified non-Extended-Format on the define, but the base cluster is an
Extended-Format data set. Programmer Response: Check the definition of the base cluster to ensure that it is also non-Extended-Format. |
| 38 | Explanation: An AIX
(alternate index) data set specified Extended-Format on the define, but the base cluster is not an
Extended-Format data set. Programmer Response: Check the definition of the base cluster to ensure that it is also Extended-Format. The data class attribute is the source for requesting Extended-Format, so verify that the proper data class was used |
| 40 | Explanation: The related object is a variable relative-record data set. |
| 42 | Explanation: The data set type in the RELATE parameter for a
DEFINE ALTERNATEINDEX command is an extended addressability ESDS. Programmer Response: Change the type of the related data set to a non-extended addressability ESDS. |
46![]() |
Explanation: The base cluster specified by an IDCAMS DEFINE
ALTERNATEINDEX RELATE parameter was not defined as a DATABASE. Programmer Response: Change the RELATE to a base cluster defined as a DATABASE, and resubmit the job. ![]() |
| Reason Code | Description |
|---|---|
| 0 | Explanation: An unexpired purge date exists. An attempt to
delete an entry failed because its expiration date has not been reached, and the DELETE command did
not specify the PURGE option. Programmer Response: Specify the PURGE option if wanted. Run the DELETE command again. |
| 2 | Explanation: There are conflicting date formats. An attempt
to retrieve a date in the new format (YYYYDDD) failed because the request used the old format (YYDD)
by passing the old format field dictionary name DSETEXDT or DSETCRDT. The date cannot be passed
correctly in the old format. Programmer Response: Submit the job again using the new format field dictionary name DSCRDT2 (creation date) or DSEXDT2 (expiration date). |
| 4 | Explanation: An unexpired new format purge date exists. An
attempt to delete an entry failed because its expiration date has not been reached, and the DELETE
command did not specify the PURGE option. This expiration date is stored in the new format (YYYYDDD)
and it is beyond the year 1999. Programmer Response: Specify the PURGE option if wanted. Run the DELETE command again. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: No related PATHENTRY name was found on the path
catalog record. Programmer Response: Ensure that the PATHENTRY name is correct. If it is, refer to access method services, DIAGNOSE command, to obtain additional information. |
| 2 | Explanation: An internal logic error occurred.
Programmer Response: Contact the IBM Support Center. |
| 4 | Explanation: Something other than a CLUSTER or alternate
index type object specified the RECATALOG parameter. Programmer Response: Ensure that the object being recataloged is a cluster or alternate index. |
| 6 | Explanation: Either the primary VSAM volume record (VVR)
points to another catalog, or the primary VVR or non-VSAM volume record (NVR) for the object being
recataloged was not found on the first volume serial number specified. The primary VVR or NVR
contains the data set information needed to recatalog the object.
Possible causes of this error are:
Programmer Response: If no VVR exists, then re-issue the DEFINE command, without the RECATALOG parameter, for the ICF catalog. If the VVR exists but points to a different catalog, specify the correct catalog and re-issue the DEFINE command with the RECATALOG parameter. If the original values for parameters NAME, INDEXED, LINEAR, NONINDEXED, NUMBERED, and VOLUMES were not specified, specify the original values and re-issue the DEFINE command with the RECATALOG parameter. |
| 8 | Explanation: The RECATALOG parameter is incorrect on the DEFINE command for an ICF catalog. |
| 10 | Explanation: The catalog associated with this data set does
not match the catalog name found in the VVR. Programmer Response: You can only recatalog pagespace, swapspace, or SYS1 data sets to a different catalog than the one specified in the VVR. If the data set you are recataloging is one of those types, or if you are getting this error in response to a REPRO MERGECAT command, contact the IBM support center. If your data sets are not one of those types, print the VVR to determine which catalog the data set should be associated with. |
| 12 | Explanation: The VVR for the data set being recataloged indicated it was for a LINEAR data set, but the DEFINE RECATALOG command did not specify the LINEAR keyword. |
| 14 | Explanation: The DEFINE RECATALOG command specified the LINEAR keyword, but the VVR for the data set did not indicate it was a LINEAR data set. |
| 16 | Explanation: NVR for the object being recataloged was not found on the volume serial numbers specified. |
| 18 | Explanation: Something other than the expected NVR was retrieved. |
| 20 | Explanation: A DEFINE NONVSAM RECATALOG request was issued
on a volume that does not have the UCBSMS indicator on. Programmer Response: This could result from an IDCAMS DEFINE NONVSAM RECATALOG request or an IDCAMS REPRO request that would cause the DEFINE RECATALOG to be issued. A DEFINE NONVSAM RECATALOG request is valid only for SMS NONVSAM data sets. Therefore, the volume specified must have the UCBSMS indicator set to on. Check to see if the volume was removed from the active configuration or if the volume was set to non-SMS status. Correct the error and run the job again. |
| 22 | Explanation: The VVR/NVR catalog name does not match the name of the catalog currently oriented to. |
| 24 | Explanation: The DEFINE RECATALOG command detected that a
volume for a data component is missing from the volume list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 26 | Explanation: The DEFINE RECATALOG command detected that the
last volume for a data component is missing from the volume list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 28 | Explanation: The DEFINE RECATALOG command detected that the
last volume of a stripe for a data component of a striped VSAM data set is missing from the volume
list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 30 | Explanation: The DEFINE RECATALOG command detected that a
volume for an index component is missing from the volume list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 32 | Explanation: The DEFINE RECATALOG command detected that the
last volume for an index component is missing from the volume list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 34 | Explanation: The DEFINE RECATALOG command detected that the
last volume of a stripe for an index component of a striped VSAM data set is missing from the volume
list. Programmer Response: Ensure that any missing volumes are supplied when issuing the DEFINE RECATALOG command. |
| 36 | Explanation: An indirect volume serial was used in the
DEFINE RECATALOG for a VSAM non-LDS data set. Programmer Response: Ensure that the data set is a VSAM linear data set and marked zFS. |
| 38 | Explanation: DEFINE RECATALOG using an indirect VOLSER was
attempted for a VSAM indexed data set. Programmer Response: Ensure that the data set is a VSAM linear data set and is marked zFS. |
| 40 | Explanation: DEFINE RECATALOG using an indirect VOLSER entry
was not marked zFS or was a non-LDS data set. Programmer Response: Ensure that the data set is a VSAM linear data set and marked zFS. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An attempt was made to delete the Master
Catalog. Programmer Response: Determine if the correct catalog is specified. If so, run the job again with a different master catalog. |
| 4 | Explanation: The system was unable to determine if the
catalog is empty. Programmer Response: Specify FORCE, RECOVERY, or run DIAGNOSE and recommended action. |
| 6 | Explanation: An incorrect DELETE TRUENAME request was
specified. The associated base object exists. Programmer Response: User error. |
| 8 | Explanation: A pagespace record was damaged. It could not be
determined if pagespace was active. Programmer Response: Run DIAGNOSE and take the recommended action. |
| 10 | Explanation: The generation data set was not found in the
GDG. Programmer Response: Run LISTCAT to determine the generation data sets in the GDG. Run the delete job again with the correct generation/version number. |
| 12 | Explanation: A required FILE parameter was not specified on
the DELETE VVR command. Programmer Response: Specify FILE parameter. Run the job again. |
| 14 | Explanation: No DD was found to match the supplied DD name
on the DELETE VVR request. Programmer Response: Check FILE parameter. Run the job again with the correct DD name. |
| 16 | Explanation: DELETE VVR request for a VVR with an associated
catalog. Programmer Response: User error. |
| 18 | Explanation:
The RECOVERY parameter is missing. Programmer Response: Specify the RECOVERY parameter. Run the job again. |
| 20 | Explanation: A DELETE NVR request
for an existing cataloged non-VSAM data set which has the same volume is not allowed. The volume
associated with the DD specified by the FILE parameter must not match the volume of an existing
nonVSAM catalog entry. Programmer Response: This is a user error. Correct the volume in the DD statement and try the request again. ![]() |
| 22 | Explanation: No DD was found to match the DD name on the
DELETE NVR request. Programmer Response: User error. Respecify the DDname in the FILE parameter. Run the job again. |
| 24 | Explanation: The request is to delete an SMS data set only,
but the data set is non-SMS managed.
|
| 26 | Explanation: A required FILE parameter was not specified on
the DELETE NVR command.
|
| 30 | Explanation: DELETE VVR resulted in an attempt to delete a
DSCB that has an associated VVR with a catalog name other than the one specified. Nothing was
deleted.
|
| 32 | Explanation: For DELETE VVR/NVR, the VVR/NVR was not found,
but a DSCB was found. The DSCB was deleted. Programmer Response: This is an informational message. No action is required. |
| 34 | Explanation: DELETE VVR resulted in an attempt to delete a
non-VSAM DSCB. Nothing was deleted. Programmer Response: User error. DELETE VVR cannot be used to delete non-VSAM data sets. |
| 36 | Explanation: DELETE VVR resulted in an attempt to delete a
DSCB whose name resolves to an associated keyrange VVR. Nothing was deleted. Programmer Response: User error. Use DELETE CLUSTER. |
| 38 | Explanation: For DELETE VVR, both the VVR and DSCB were not
found. Nothing was deleted. Programmer Response: Informational message. Neither the VVR nor the DSCB were found. The object name may be misspelled. If so, run the job again with the correct object name specified. |
| 40 | Explanation: For DELETE VVR, the DSCB was not found.
Programmer Response: Informational message. The VVR was found, but the associated DSCB was not found. The VVR is deleted. |
| 42 | Explanation: An NVR was retrieved during a DELETE VVR
request. Programmer Response: User error. Specify DELETE NVR and run the job again. |
| 44 | Explanation: A VVR was retrieved during a DELETE NVR
request. Programmer Response: User error. Specify DELETE VVR and run the job again. |
| 46 | Explanation: DELETE VVR failed to specify the system master
catalog name in the catalog parameter. Programmer Response: User error. Rerun the failing DELETE VVR job specifying the system master catalog name in the catalog parameter. |
| 48 | Explanation: DELETE CLUSTER failed because the data set is
using RLS resources. Programmer Response: This data set must be deleted on a DFSMS 1.3 or higher system to ensure the RLS resources are freed. |
| 50 | Explanation: DELETE failed because SMSVSAM Server was not
available. Programmer Response: Retry the operation when the SMSVSAM Server is available. |
| 52 | Explanation: The SMSVSAM Server encountered an internal
error performing the delete operation. Diagnostic data will be written to Logrec, and a system dump
may have been taken. Programmer Response: Refer the problem to IBM programming support center. |
| 54 | Explanation: DELETE failed because the data set is being renamed but it
has not completed. Programmer Response: Rename the data set with the IDCAMS ALTER command and then delete it. |
| 56 | Explanation: A DELETE USERCATALOG or EXPORT DISCONNECT command issued
against a user catalog failed because the catalog contains one or more user catalog connector
extension records, which are not allowed in a pre-z/OS V1R13 system. Programmer Response: To delete user catalog connector records, issue EXPORT DISCONNECT for the user catalog on a system at the z/OS® V1R13 level or higher. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: The correct volume was not mounted for OBTAIN.
Programmer Response: Check the JCL and file parameters, and ensure that the required volume is mounted. |
| 8 | Explanation: OBTAIN did not find requested format-1 DSCB on
specified volume. Programmer Response: Ensure that the correct volume is mounted. |
| 12 | Explanation: OBTAIN encountered an I/O error in the volume's
VTOC. Programmer Response: Check for a possible hardware error. |
| x | Explanation: The reason code is the OBTAIN return code.
Programmer Response: Determine the meaning of the obtain return code. Correct the error. Run the job again. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The key specified for spanned record exceeds
the control interval size. Programmer Response: Correct the erroneous parameter (KEYS or RECORDSIZE). Run the job again. |
| 4 | Explanation: The maximum logical record size for spanned
records exceeds the control area size. Programmer Response: Correct the erroneous parameter (KEYS or RECORDSIZE). Run the job again. |
| 6 | Explanation: The alternate index key position plus the key
length for the base cluster is larger than the control interval size minus 10 for spanned records.
Programmer Response: Correct the erroneous parameter (KEYS or RECORDSIZE). Run the job again. |
| 8 | Explanation: The alternate index key position plus the key
length for the base cluster is larger than the record size. Programmer Response: Correct the erroneous parameter (KEYS or RECORDSIZE). Run the job again. |
| Reason Code | Description |
|---|---|
| x | Explanation: The reason code is the same as returned by the
DADSM RENAME function in the status byte of the RENAME volume list. Programmer Response: Determine the meaning of the RENAME return code, as documented in the "Status Codes from RENAME" section in z/OS DFSMSdfp Diagnosis. Correct the error. Run the job again. |
| Reason Code | Description |
|---|---|
| 10 | Explanation: The data set name is indicated as a NEWNAME in
an ALTER NEWNAME request that has not completed. Programmer Response: Determine if the ALTER NEWNAME request has completed. If so, run the request again to get the correct information. |
| Reason Code | Description |
|---|---|
| x | Explanation: The reason code is the DADSM SCRATCH function
status code. Programmer Response: Determine the meaning of the SCRATCH status code. See z/OS DFSMSdfp Diagnosis for these status codes and take the appropriate corrective action before rerunning the job that failed. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: Write not allowed to a catalog (BCS) that
resides on a volume with the read-only attribute. Programmer Response: Contact your System Administartor about the read-only status of the volume. Re-run the request when write access is allowed to the volume. |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: The message indicates that the caller's AMS release level or maintenance level is different from the CATALOG level that is being called. Ensure that IDCAMS and CATALOG are at the same level. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: The data set to which an ALTER RENAME command
is directed is RACF indicated. However, there is no RACF profile. Programmer Response: Make the data set RACF-protected or remove the RACF indicator. |
| 8 | Explanation: An ALTER RENAME command has been issued for a
RACF-protected data set. This failed because as a result of the new name, the data set cannot be
defined to the security subsystem. Programmer Response: Use a new name acceptable to the security subsystem. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: An internal logic error occurred.
Programmer Response: Probable system error. Contact the IBM Support Center. However, if a user program is interfacing directly with catalog management, the FPL contains improper data. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: As a result of an IMPORT or DEFINE command,
VSAM has attempted to establish a RACF profile for a
cluster/alternate index, data, or index object. This failed because a profile with the same name
already exists. Programmer Response: Either:
|
| Reason Code | Description |
|---|---|
| 24 | Explanation: An incorrect association was returned during
upgrade retrieval. Programmer Response: An IDCAMS DIAGNOSE should be run against the catalog and any errors identified corrected. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: As the result of a DEFINE, IMPORT, or IMPORTRA
command, VSAM attempted to define a RACF profile for the
object. The profile could not be established because the user does not have sufficient authority for
the specified data set characteristics. Programmer Response: Check the installation security subsystem guidelines for defining a data set in the security subsystem. Modify the data set characteristics accordingly. |
| 12 | Explanation: As a result of a DEFINE, IMPORT or IMPORTRA
command, VSAM attempted to define a RACF profile for the
object. RACF was incapable of building the profile.
Programmer Response: RACF was inactive and could not process the profile build request. To activate RACF, contact the system security administrator. |
RETURN CODE 120 Explanation: Attempt to modify the non-existent or system field. This is a system error.
RETURN CODE 122 Explanation: Reflects error return code 8 when set by the common filter service. Refer to the Catalog Search Interface information in z/OS DFSMS Managing Catalogs for additional information about this return code.| Reason Code | Description |
|---|---|
| 0 |
Explanation: invalid field name passed. Programmer Response: Contact the IBM Support Center. |
| 2 | Explanation: The storage management subsystem field in the
BCS is inconsistent with that field in the VVDS entries. Programmer Response: Contact the IBM Support Center. |
| 32 | Explanation: Invalid filter key was provided. This return code may also
indicate an invalid data set name was encountered in the catalog being searched. Programmer Response: Correct filter key, run IDCAMS DIAGNOSE on the catalog being searched to determine if there are any entries in error. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An incorrect relative block address (RBA)
return code was returned from VSAM record management. Programmer Response: This is a system error indicating that the catalog may need to be restored. Use of the access method services list catalog (LISTCAT) or DIAGNOSE commands may help identify the incorrect entry. It may be necessary to contact the IBM Support Center. |
| 34 | Explanation: DASDCALC returns either an incorrect physical
block size or an incorrect index into the physical block size table. Programmer Response: The possible cause of this error is a CI size that is not compatible with the physical device. Correct the CI size and rerun the job. |
| 36 | Explanation: VSAM record management has returned an invalid
CI error on an access to a catalog record. This error generally occurs because an invalid CIDF or
RDF is detected within a catalog CI. One possible cause is damage as a result of a hardware failure.
An IEC331I message is issued and the SFI information will contain additional information about the
VSAM error. Programmer Response: Run an access method services DIAGNOSE command, and EXAMINE DATATEST against the catalog. The catalog may need to be recovered. |
| Reason Code | Description |
|---|---|
| ACS reason code = catalog reason code + 1000 | Explanation: Catalog management can only support ACS
services reason codes from 1000 to 1255. The ACS services return and reason codes are documented in
the z/OS DFSMSdfp Diagnosis.
Programmer Response: For the ACS reason code referenced in the appropriate SMS SUB-System Message Manual. Refer to the Storage Management Subsystem Reason Codes, Sub-Sections Subsystem Interface Reason Codes and ACS Service Reason Codes in the z/OS DFSMSdfp Diagnosis for a complete description of the reason codes. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: An integrity check of the user catalog
parameter list (CPL), the FPL, or the FVT, failed. Programmer Response: Contact the IBM Support Center unless a user-written program is interfacing directly with catalog management. |
| 2 | Explanation: A storage validity check failed on a user FPL
or on the user work area referenced from the CPL. Programmer Response: Contact the IBM Support Center unless a user-written program is interfacing directly with catalog management. |
| 6 | Explanation: A CPL field that references the work area is
zero. Programmer Response: Contact the IBM Support Center unless a user-written program is interfacing directly with catalog management. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: Only the old name catalog entry remains to be deleted, but the VTOC still has the DSCB with the old name. |
| 6 | Explanation: Only the old name catalog entry remains to be deleted, but the VVDS still has the NVR with the old name. |
| 8 | Explanation: The DSCB has been renamed, but no DSCB with either the old name or the new name can be found. |
| 10 | Explanation: The data set DSCB cannot be located. |
| 12 | Explanation: The NVR has been renamed, but the NVR with the new name cannot be located. |
| 14 | Explanation: There should be an NVR with the old name, but that NVR cannot be located. |
| 16 | Explanation: The DSCB has been renamed without error, but the NVR cannot be renamed because there is already an NVR with that name. |
| 18 | Explanation: The data set name specified in NEWNAME is involved in another ALTER NEWNAME request that is not yet complete. |
Incorrect or missing parameter in Catalog
request.
| Reason Code | Description |
|---|---|
| x | Explanation: An expected field value was not supplied or an
internal logic error occurred. This is probably a logic error in the caller of catalog management.
Programmer Response: Contact the IBM Support Center. |
| 0 | Explanation: Expected component not found. |
| 10 | Explanation: A UCB address passed to the Catalog Address
Space was found to be invalid during an attempt to capture the UCB in the Catalog
Space. Programmer Response: Attempt to rerun the failing request. If it continues to fail, create an SVC dump by using the MODIFY CATALOG,DUMPON command and contact the IBM Support Center. |
18![]() |
Explanation: Required DEVTYPE parameter
missing. Programmer Response: Resubmit the request specifying the DEVTYPE parameter. ![]() |
| 20 | Explanation: There is no pointer to the catalog work area in
the catalog parameter list, and the DEFINE function is unable to return the names generated for a
component. Programmer Response: Contact the IBM Support Center unless a user-written program is interfacing directly with catalog management. |
| 48 | Explanation: The AMDSB information has not been found in the
VVR, or VSAM CLOSE passed invalid AMDSB data to update the VVR. In the latter case, message IEC251I
will be issued. Programmer Response: Run the DIAGNOSE command to check for a damaged catalog record. Contact the IBM Support center if message IEC251I was issued. |
| 122 | Explanation: Define master catalog or user catalog with extended format information or attributes extension information is not valid. |
| 124 | Explanation: Backout while open specification not valid for non-VSAM data set. |
| 126 | Explanation: Backout while open specification not valid for ALTER of non-SMS data set. |
| 128 | Explanation: An internal logic error has
occurred. Programmer Response: Contact the IBM Support Center. |
| 130 | Explanation: An internal logic error has
occurred. Programmer Response: Contact the IBM Support Center. |
| 132 | Explanation: Record Level Sharing attributes not valid for non-VSAM data set. |
| 134 | Explanation: Record Level Sharing attributes not valid for non-SMS data set. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has occurred.
Programmer Response: Contact the IBM Support Center. |
| 20 | Explanation: The key length is required and has not been
provided. Programmer Response: Ensure that a valid key length is specified for the data set. |
| 22 | Explanation: A unique data set needs a DD statement for a
rename, or the DD statement is missing. Programmer Response: Supply a dname job control statement. |
| 32 | Explanation: An alias name was not provided on a DEFINE
command. Programmer Response: Correct the DEFINE command. Run the job again. |
| 34 | Explanation: GDG limit or attribute data was not provided on
a DEFINE command. Programmer Response: Correct the DEFINE command. Run the job again. |
| 40 | Explanation: A required DD statement is missing for a
mountable unit. The system is unable to mount the volume required for DELETE NONVSAM SCRATCH
processing. Programmer Response: Use file parameter on DELETE and allocate a mountable unit to the job through a DD statement. Specify DEFER mount. |
| 42 | Explanation: An error occurred from IDA0192V while
attempting to mount a volume required for DELETE NONVSAM SCRATCH processing. Programmer Response: Ensure that the mountable unit was allocated for DELETE processing. |
| 46 | Explanation: No storage class information was passed for an SMS managed data set. |
| Reason Code | Description |
|---|---|
| x | Explanation: Volume status code from DADSM. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: The index component was found for relative
record data set or entry-sequenced data set. This is a system error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 4 | Explanation: The key range is incorrect for catalog define,
or the key ranges are not specified in ascending sequence in the DEFINE of a VSAM key sequenced data
set. Programmer Response: Correct the DEFINE command. |
| 6 | Explanation: Key ranges were found on both data and cluster
catalog FVT. This is a system error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 8 | Explanation: The work area is too small. This is a system
error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 10 | Explanation: Space parameters were found on both cluster and
data catalog FVT. This is a system error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 20 | Explanation: The key lengths for data and index are not
equal. This is a system error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 28 | Explanation: There are an unequal number of volume serial
numbers and file sequence numbers in list entries. Programmer Response: Correct the input. Run the job again. |
| 30 | Explanation: More device type entries exist than volume
serial numbers. Programmer Response: Correct the input. Run the job again. |
| 34 | Explanation: An incorrect space request type on DEFINE was
detected. This is a system error. Programmer Response: If the reason code indicates a system error, contact the IBM Support Center. Otherwise, follow the programmer response indicated by the reason code. |
| 44 | Explanation: A relative-record data set has a maximum record
length that is not equal to the average record length. Programmer Response: Correct the input. Run the job again. |
| 60 | Explanation: The logical record size for an ICF catalog has
been exceeded. The DEFINE ALIAS has caused the updated catalog record to exceed the catalog's
logical record size. Programmer Response: Redefine the catalog record size to increase the logical record size to a value up to the 32,400 byte maximum. Run the DEFINE of the alias again. If the catalog record size is already 32,400, no more aliases may be defined for this catalog. A new catalog needs to be created for subsequent aliases, or existing aliases need to be deleted from the current catalog. |
| 62 | Explanation: The maximum average logical record size is less
than 4086 bytes for an ICF catalog define. Programmer Response: Increase the maximum average logical record size. Run the DEFINE command again. |
| 64 | Explanation: An incorrect group code for field management
was detected. Programmer Response: This is a system programming error. |
| 66 | Explanation: The component key length exceeds the limit.
Programmer Response: Run the DIAGNOSE command to check for a damaged catalog record. |
| 72 | Explanation: Duplicate volumes exist in the volume list of a
non-keyrange data set. Programmer Response: For a DEFINE, remove the duplicate volume from the volume list and rerun the DEFINE. For an ALTER ADDVOLUMES, a volume being added might already exist as a primary or candidate volume for the data set; therefore, remove the volume from the ADDVOLUMES list and rerun the ALTER. |
| 74 | Explanation: The define of a VVDS had the INDEX option
specified. A VVDS is an entry sequenced data set. Programmer Response: Remove the INDEX option. Run the define operation again. |
| 78 | Explanation: The request to field management was not valid.
Programmer Response: Check the CPL for calling field management. |
| 80 | Explanation: The size of the generation data set subrecord
exceeds the maximum spanned record size of the ICF catalog. Programmer Response: Do one of
the following:
|
| 82 | Explanation: Key ranges are not allowed on a DEFINE of an
ICF catalog. Programmer Response: Remove the KEYRANGES parameter. Run the DEFINE command again. |
| 84 | Explanation: The REUSE parameter was specified with UNIQUE
or KEY ranges. Programmer Response: Remove one of the conflicting parameters. Run the DEFINE command again. |
| 90 | Explanation: More than one volume serial number is specified
for the DEFINE request of a non-VSAM data set, and one of the volume serial numbers is an indirect
volser ****** or a symbolic volser &xxxxx. Programmer Response: If the indirect or the symbolic volser feature (a non-VSAM data set defined with a volser of ******) is wanted, remove the other volsers from the DEFINE request. |
| 92 | Explanation: A format 2 work area is incorrect for this
catalog request. Programmer Response: Run the job again with a format 1 work area. |
| 94 | Explanation: DEFINE NONVSAM no BCS for a non-SMS managed data set cannot be requested. |
| 96 | Explanation: DEFINE NONVSAM no NVR for a non-SMS managed data set cannot be requested. |
| 98 | Explanation: The new record length exceeds the maximum VVR or NVR size. |
| 100 | Explanation: The number of volumes passed exceeds the number of UCB addresses. |
| 102 | Explanation: The Volser in the UCB does not match the volser in the volume list. |
| 104 | Explanation: An incorrect number of device types were passed for the ALTER non-specific volume request. |
| 106 | Explanation: An incorrect number of volumes were passed for the ALTER non-specific volume request. |
| 110 | Explanation: Either of the following problems occurred:
Programmer Response: Define the data set with a smaller space allocation request. |
| 112 | Explanation: An incorrect high-allocated RBA was found
during a define of a data component. The high-allocated RBA was less than the high-used RBA.
Programmer Response: Reduce the amount of space specified for the data component of the cluster. Enter the DEFINE command again. |
| 116 | Explanation: A request was made to compress a data set that
is not an Extended Format data set. Programmer Response: Contact the IBM Support Center. |
| 120 | Explanation:Compressible request is allowed for KSDS data
set only. Programmer Response: Change the job to define the data set as a non-compressible data set. |
| 122 | Explanation: Catalog G2000Vxx causes
the GDG to exceed the limit of 11,999.Programmer Response: Clean up the GDG in error then catalog G2000Vxx. ![]() |
| 124 | Explanation: Invalid data set type for extended
addressability. Programmer Response: Check the SMS DATACLAS attributes regarding extended format and extended addressability. A VSAM data set that has the extended addressable attribute must also be extended format unless it is a linear data set (LDS). |
| Reason Code | Description |
|---|---|
| x | Explanation: Return code from OBTAIN. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An incorrect first character, non-alphabetic,
was detected. The alternate index or path name is incorrect. Programmer Response: Correct the entry name. |
| 6 | Explanation: The data and index names are not allowed for a
catalog. Programmer Response: Avoid the use of names at the INDEX and DATA level of DEFINE MASTERCATALOG and DEFINE USERCATALOG. |
| 8 | Explanation: A syntax error was encountered in examining a
GDG name. Programmer Response: Correct the name. Run the job again. |
| 10 | Explanation: A reserved high-level qualifier name was
specified on an ICF define operation. CATINDEX is a reserved high-level qualifier. Programmer Response: Change the name to use a different high-level qualifier. Run the define operation again. |
| 12 | Explanation: The data name specified for an SMS VSAM data set does not orient to the same user catalog that the cluster did. This is a requirement of SMS managed data sets that all components must be locatable through the Catalog's standard order of search. |
| 14 | Explanation: The data set name to be added to the catalog does not meet
the syntax requirements for a valid cataloged data set name. For information about valid cataloged
data set names, see z/OS DFSMS Using Data Sets. Programmer Response: Correct the data set name so that it meets the requirements for a valid cataloged data set name. |
| 16 | Explanation: The index name does not resolve to the same catalog as the cluster name did. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: An incorrect storage class name length was detected. |
| 4 | Explanation: An incorrect data class name length was detected. |
| 6 | Explanation: An incorrect management class name length was detected. |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: If the catalog and all of its entries are to be deleted specify the FORCE parameter on the access method services DELETE CATALOG command. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: A GETMAIN failure occurred. There is
insufficient virtual storage available. Programmer Response: Increase the region size available to the step. |
| 10 | Explanation: A GETMAIN failure occurred. There is
insufficient virtual storage available for the catalog communication area. Programmer Response: Increase the region size available to the step. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: One of the following has occurred:
Programmer Response: Specify a device type or device name that is acceptable to the system. |
| 4 | Explanation: An incorrect device name was specified on a
define of a non-VSAM entry. Programmer Response: Specify a device type or device name that is acceptable to the system. |
| Reason Code | Description |
|---|---|
| x | Explanation: The return code from a failed DADSM RENAME. |
| 2 | Explanation: A duplicate name was detected on a volume
during a define of a data set. Programmer Response: Select another data set name, scratch the original data set from the volume, or ensure that there are as many volumes as key ranges for the define of a unique key sequenced data set (KSDS). |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Delete any unneeded data sets or data spaces from the volume to make additional DSCBs available, or re-create the volume with a larger VTOC. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: The open-for-output indicator was found on in
the catalog while a partial release request was being processed. Partial release processing cannot
occur if there are other users opened to the data set. Programmer Response: Run an IDCAMS verify against the data set to reset the open-for-output indicator and re-run the partial release request. |
| 4 | Explanation: The data set is not an extended format VSAM cluster. Partial release processing is supported only for extended format VSAM clusters. |
| 6 | Explanation: The data set name passed to a VSAM partial
release request was not a VSAM cluster data component. Programmer Response: Ensure the name being passed is the VSAM cluster data component and re-run the partial release request. |
| 8 | Explanation: A DADSM partial release request failed.
Programmer Response: Examine the job and system log for related messages explaining the DADSM failure. |
| 10 | Explanation: An attempt was made to perform partial release processing against a data set defined with guaranteed space. Guaranteed space data sets are not supported for partial release processing. |
| 12 | Explanation: An attempt to release excess space has been
made for this data set, but the data set is not eligible for partial release processing. The data
set is a multi-volume data set that was created through space constraint relief processing and the
high use RBA for the data set is not in the range of an extent on the last volume of the data
set. System Action: The request to release the space is ignored. |
| 14 | Explanation: Rounding for multi-cylinder unit (MCU) boundary prevented
partial release of space. System Action: The request to release the space is ignored. |
| 18 | Explanation:
The primary volume RBAs are out of order for this multivolume partial release request. Correct,
and rerun. Programmer Response: Run IDCAMS DEFINE RECATALOG with the volumes in RBA order. |
| Reason Code | Description |
|---|---|
| x | Explanation:
Internal logic error. Programmer Response: Information about the reason codes can be found in z/OS V2R3.0 DFSMSdfp Diagnosis, Table 65. DADSM UPDATE Diagnostic Information. A x'15' may indicate that your volumes have not been properly added to your storage groups. If this information does not help you resolve the problem, contact the IBM Support center. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: A rename is not allowed for an open data set. The backout has been done successfully. |
| 2 | Explanation: The data set is currently open to another user. |
| 4 | Explanation: The data or index component (or both) is in
use, and the data set cannot be deleted. Programmer Response: Run the command again. To ensure proper completion, specify a disposition parameter of OLD, not SHR. |
| 6 | Explanation: The attempted DELETE or ALTER of a PAGESPACE,
or attempted DELETE CATALOG FORCE that implicitly deletes a PAGESPACE, cannot be allowed. The
pagespace is currently in use on this or another system sharing the volume that contains the
pagespace. Programmer Response: If a PAGESPACE is to be deleted or altered, it must not be in use by any system that shares the volume on which it is located. |
| 8 | Explanation: The data set is in use by another job; this
reason code usually means that a Backup-While-Open (BWO) dump of the data set is in progress.
Programmer Response: Run the requested function again after verifying the data set is not currently being dumped. |
| 10 | Explanation: An attempt has been made to alter one of the
attributes LOG, LOGSTREAMID, or BWO for a data set that is currently open. System Action: The request is terminated. Programmer Response: Reissue the ALTER request when the target data set is not open. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: Lock verification failed. Programmer Response: An unauthorized caller attempted to access a locked catalog. To access a locked catalog, a user must have read authority to the profile IGG.CATLOCK of class type FACILITY. Obtain the correct authorization. Run the job again. |
| 2 | Explanation: Access was denied for one of the following
reasons:
Programmer Response: Either define the profile IGG.CATLOCK, activate RACF, or supply an MVS router exit. |
| 4 | Explanation: The caller was not authorized for DEFINE LOCK.
Programmer Response: To use the DEFINE LOCK command, a caller must have read authority to the profile IGG.CATLOCK of class type FACILITY. Obtain the correct authorization. Run the job again. |
| 6 | Explanation: The caller was not authorized for ALTER LOCK.
Programmer Response: A caller attempted to issue either the ALTER LOCK command for an unlocked catalog, or the ALTER UNLOCK command for a locked catalog for which the caller was unauthorized. To use the ALTER LOCK and ALTER UNLOCK commands, a caller must have read authority to the profile IGG.CATLOCK of class type FACILITY. Obtain the correct authorization. Run the job again. |
| 8 | Explanation: The catalog cannot be unlocked because it is
currently suspended from a z/OS V2R1 system. Programmer Response: To unlock the catalog, resume catalog activity from a z/OS V2R1 system. If catalog activity is not suspended, then contact IBM support. |
| Reason Code | Description |
|---|---|
| 6 | Explanation: The catalog is temporarily unavailable.
Programmer Response: Try the request again later. If a COPY or IMPORT operation failed, do a DELETE RECOVERY and import a backup copy of the catalog. As a volume error code: Catalog unavailable for the remainder of processing which establishes volumes as candidates for future extension. This occurs during define of VSAM data sets only when another error is encountered during candidate processing. This code appears as a volume error code for the volumes that are not processed because the other error code that appears in the access method services job stream output. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The function was ALTER BCS only. |
| 2 | Explanation: The function was DIRECTED CATALOG. |
| 4 | Explanation: The function was DEFINE NONVSAM with no BCS. |
| 6 | Explanation: The function was DEFINE NONVSAM with no NVR. |
| 8 | Explanation: The function was DELETE NVR with no BCS check. |
| 10 | Explanation: The function was DELETE NOSCRATCH. |
| 12 | Explanation: The function was DELETE GDG FORCE. |
| 14 | Explanation: The function was ALTER UNCONVERT from SMS managed VSAM data set back to non-SMS managed. |
| 16 | Explanation: The user is not authorized to
alter the storage class or management class of an
SMS-managed data set. Programmer Response: Insure that the user has read access authority to 'STGADMIN.IGG.ALTER.SMS. |
| 18 | Explanation: The user is not authorized to perform an ATL
define, alter, or delete request. Programmer Response: Insure that the user has read access authority to 'STGADMIN.IGG.LIBRARY'. |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Reduce the maximum logical record length or define the data set as spanned. |
| Reason Code | Description |
|---|---|
| 8 | Explanation: MLA was unavailable for the request.
Programmer Response: Enter the F CATALOG, MLA(REFRESH) or F CATALOG, RESTART command to re-enable the MLA. |
| 10 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 14 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 18 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 20 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 28 | Explanation: An error occurred during a generic search of the alias table for the input data set name. |
| 30 | Explanation: MLA was unable to obtain sufficient memory to hold its in-storage tables. |
| 34 | Explanation: MLA was unable to obtain sufficient memory to rebuild its in-storage tables. |
| 40 | Explanation: The system number of qualification was not
between 1 and 4. The search order of the multi-level alias facility is undefined. All requests
requiring the multi-level alias facility fails until the situation is rectified. Programmer Response: Use the MODIFY CATALOG,ALIASLEVEL operator command to send a valid level of qualification. |
| 42 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 44 | Explanation: MLA detected a damaged master catalog record. A snap dump was taken to aid in resolution of the problem, and MLA facility in-storage tables were invalidated. |
| 46 | Explanation: An error occurred during a generic search of the alias table for the input data set name. |
| 50 | Explanation: The MLA tables are incorrect. The generic request cannot be fulfilled. |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Reduce the control interval size of the data component. |
RETURN CODE 198 Explanation: An attempt has been made to use an unsupported feature.
RETURN CODE 200 Explanation: The specified or defaulted control interval size of the index component is greater than the maximum block size of the index device.
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Reduce the control interval size of the index component or use a different device with a larger maximum block size. |
RETURN CODE 202 Explanation: Storage management subsystem call error.
| Reason Code | Description |
|---|---|
| 0 | Explanation: An error was detected during a call to SMS.
Programmer Response: Print the OBR record to get the appropriate error messages. |
| 2 | Explanation: An error was detected during a call to determine whether all volumes belong to the same storage group. |
| 4 | Explanation: An incorrect definition was passed to the SMS. |
| 6 | Explanation: Insufficient space was provided for that definition to the SMS subsystem. |
| 8 | Explanation: An attempt was made to alter the expiration
date of an SMS-managed data set that was defined with a management class whose maximum number of
retention days was specified as zero. Programmer Response: Redefine the data set with a management class with no retention limit or with a specified retention value equal to or exceeding the date specified in the ALTER command. |
RETURN CODE 206 Explanation: Invalid CAMLST parameter list. Probable user error.
RETURN CODE 204 Explanation: Key specification extends beyond end of maximum logical record.| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Reduce the key length, change the key position, or increase the logical record length. |
| Reason Code | Description |
|---|---|
| 0 | Programmer Response: Increase the buffer size specified through the BUFFERSPACE parameter of the DEFINE command. |
| 4 | Programmer Response: Increase the buffer size specified through the BUFFERSPACE parameter of the ALTER command. |
| Reason Code | Description |
|---|---|
| x | Explanation: Return code from Subsystem call. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: The control interval and the control area
calculations are unsolvable with specified parameters. Programmer Response: Determine
which of the specifications may have caused the problem. The following are the possible
specifications:
|
| 4 | Explanation: Specified and default values result in only one
control interval per control area for a key-sequenced data set. Programmer Response: Correct the input. Run the job again. |
| 6 | Explanation: Using the specified or default values, the
maximum index control interval size for the device would be exceeded for nonunique objects.
Programmer Response: Increase the data control interval size or decrease the data control area size. |
| 8 | Explanation: Using the specified or default values, the
maximum index control interval size for the device would be exceeded for unique objects.
Programmer Response: Increase the data control interval size or decrease the data control area size. |
| 10 | Explanation: The buffer space is too small for a nonunique
object. Programmer Response: Correct the buffer size. Run the job again. |
| 12 | Explanation: The specified and default value result in only one control interval per control area for a variable relative-record data set. |
| Reason Code | Description |
|---|---|
| x | Explanation: Return code from Subsystem call. |
| Reason Code | Description |
|---|---|
| ACS reason code = catalog reason code + decimal 256 | Explanation: Adding decimal 256 to the catalog reason code
will give the correct ASC reason code. The ACS services return and reason codes are documented in
the z/OS DFSMSdfp Diagnosis
Programmer Response To ACS reason code, add decimal 256 to obtain the correct error code for reference in the appropriate SMS SUB-System Message Manual. Refer to the Storage Management Subsystem Reason Codes, Sub-Sections Subsystem Interface Reason Codes and ACS Service Reason Codes in the z/OS DFSMSdfp Diagnosis and for a complete description of the reason codes. |
| Reason Code | Description |
|---|---|
| 4 | Explanation: To OPEN a catalog, the caller must be running
in key 0 - 7, must be in supervisor state, or must be APF authorized. To do CLOSE or EOV processing for a catalog the caller must be running in key 0 - 7, must be in supervisor state, or must be APF authorized. To process the CONVERTV function, the caller must be APF authorized. Scheduler type locate (non-generic) is restricted. To issue LOCATE SVC, the caller must be running in key 0 - 7, must be in supervisor state, or must be APF authorized. Programmer Response: Respond to the particular error accordingly. If there is no fix for the problem, contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| x | An internal logic error has occurred. Programmer Response: Contact the IBM Support Center. |
| 2 | ECS workarea storage is not available. |
| 3 | Coupling Facility connection error. If received with message IEC377I, fields aaaa and bbbb contain the return and reason codes from IXLCONN. |
| 4 | An ECS request was made but the system is not ECS-active. |
| 9 | Coupling Facility disconnection error. If received with message IEC377I, fields aaaa and bbbb contain the return and reason codes from IXLDISC. |
| 13 | ECS activation was requested for a catalog with the NOECSHARING attribute. |
| 26 | Returned on a non-ECS system when an attempt is made to access a catalog that is ECS-active on another system. |
| 28 | Catalog is temporarily in use by a non-ECS system. |
| 29 | ECS-activation of a catalog is requested but the catalog does not have cross-system share options or is not on a shared volume. |
| 47 | A Coupling Facility error has occurred. Programmer Response: Consult the Coupling Facility messages that appear in the system log and correct the associated problem. Then reactivate ECS. |
| 48 | An attempt was made to add a catalog to the Coupling Facility
structure for Enhanced Catalog Sharing use, but the structure is full. Programmer Response: Increase the size of the ECS structure definition in the CFRM policy. |
| 58 | An attempt was made to connect to the ECS structure but Catalog has detected that the system is running as a VM guest. ECS cannot be activated. |
| 65 | Connecting to the CF cache is not allowed at this time until the structure is
finished with the rebuild. Programmer Response: Wait for the rebuild to finish. If the CF cache is not automatically reconnected after the rebuild, issue F CATALOG,ECSHR(CONNECT) to connect. |
| 66 | A request to enable a catalog that is quiescing cannot be accepted until the
catalog is fully quiesced on all systems. This reason code is displayed in message IEC377I. If this error is issued during IPL or at a time when catalogs are being added to ECS
without a quiesce taking place recently, this error is indication that the catalog was accessed on a
non ECS system outside of an ECS sysplex.![]() Programmer
Response: Enter the MODIFY CATALOG,ECSHR(STATUS) command on all systems in the sysplex to ensure
that the catalog displays as inactive on all systems before trying to enable again. |
| 67 | Can’t activate a catalog in ECS that resides on a volume with the
read-only attribute. Programmer Response: Contact your System Administartor about the read-only status of the volume. Re-run the request when write access is allowed to the volume. |
| Reason Code | Description |
|---|---|
| x | Explanation: The reason code represents the catalog
management return code encountered while performing SMF processing. The catalog management return
codes correspond to the return codes listed for this message. Programmer Response: Examine the reason code returned. Run the job again after performing the required corrective measures. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has
occurred. Programmer Response: Contact the IBM Support Center. |
| 24 | Explanation: The request to change a catalog’s state failed. |
| 26 | Explanation: The request to change a catalog’s state timed out. |
| 28 | Explanation: Either the specified catalog cannot be found, or the catalog is not RLS-eligible to be RLSQUIESCE or RLSENABLE. |
| 30 | Explanation: The catalog is still open somewhere in the
sysplex. Programmer Response: Use D GRS,RES=(SYSVSAM,catname*) to determine which system or job still has the catalog open. |
| 32 | Explanation: The catalog is either locked or suspended
already. Programmer Response: Use F CATALOG,ALLOCATED or IDCAMS LISTCAT to determine the current state of the catalog. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal logic error has
occurred. Programmer Response: Contact the IBM Support Center. |
| 0 | Programmer Response: Use the access method services IMPORT CONNECT command to put an entry for the user catalog into the master catalog. |
| 6 | Explanation: SMSVSAM address space is not
available. Programmer Response: Issue D SMS,SMSVSAM to examine whether SMSVSAM is active. |
| Reason Code | Description |
|---|---|
| 0 | Explanation: An ALTER of expiration date was specified, but no DD statement was supplied. |
| 4 | Explanation: The DEVTYPE function failed during DEFINE
processing. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 8 | Explanation: An incorrect device type was encountered during
DEFINE processing. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 14 | Explanation: A delete of a unique object was specified, but
no DD statement was supplied. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 16 | Explanation: A delete of a non-VSAM object with the scratch
option was specified, but no DD statement was supplied. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 18 | Explanation: A delete of a VSAM object with the erase option
was specified, but no DD statement was supplied. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 22 | Explanation: There was no DDname match found in the TIOT.
Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 34 | Explanation: The system was unable to determine the DD
statement name for a CRA. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. If these are correct, contact the IBM Support Center. |
| 36 | Explanation: Either a required DD statement is missing or,
if the user is dynamically allocating the data set, the limit to the number of data sets that can be
dynamically allocated has been exceeded. Programmer Response: Provide the required parameter, ensure that the DD statement name is correctly spelled, or that the DD statement is present for the step. Also, ensure that the volumes can be allocated by dynamic allocation. Check the DYNAMNBR parameter in the user's LOGON procedure to determine if the limit on the number of data sets that can be dynamically allocated was exceeded. If these are correct, contact the IBM Support Center. |
| Reason Code | Description |
|---|---|
| x | Explanation: An internal error has occurred. System Action: An SVC dump may be produced for the error, depending on the reason code. Processing of the catalog request is terminated. Programmer Response: Determine if an SVC dump was created for this failure, and contact the IBM Support Center for assistance. |
| 26 | Explanation: An overlay in the Access Control Block (ACB) or CAXWA for
an ICFCATALOG has been detected. A dump is taken and the Catalog Address Space is restarted
internally to invalidate the affected control blocks. Programmer Response: Please provide any dumps to IBM support. Prepare to re-IPL the system(s) that got the 246-26 dumps to rebuild the ACBs as soon as possible. |
| 28 | Explanation: A broken CAXWA chain has been detected. A dump is taken
and a IEC366E WTO message is issued. An IPL is recommended at the earliest convenience to avoid any
unrecoverable errors because of the broken CAXWA chain. Catalog address space is not
restarted. Programmer Response: Provide any 246-28 dumps to IBM support to make sure that the overlay is corrected. |
| Reason Code | Description |
|---|---|
| 2 | Explanation: The opening of a catalog failed during catalog reorientation. |
| 4 | Explanation: The allocation of a catalog unit failed. |
Programmer response
Information about the reason codes can be found in z/OS DFSMSdfp Diagnosis, Table 65. DADSM UPDATE Diagnostic Information. A x'15' may indicate that your volumes have not been properly added to your storage groups. If this information does not help you resolve the problem, contact the IBM Support Center.
Source
DFSMSdfp
Module