LMPRINT—print a partitioned or sequential data set

Command invocation format

Read syntax diagramSkip visual syntax diagram ISPEXEC LMPRINT DATAID( data-id)MEMBER( member-name) INDEX FORMAT(YES)FORMAT(NO) NOLLA

Call invocation format

Read syntax diagramSkip visual syntax diagramCALLISPLINK('LMPRINTb', data-id,member-name'b','INDEX''b','YES''b''NOb','NOLLAbbb''b');

OR

Read syntax diagramSkip visual syntax diagramCALLISPEXEC( buf-len, buffer);

Return codes

 0
Normal completion.
 4
Either:
  • Data set is empty or contains an empty member.
  • No members matched the pattern.
 8
Member not found.
10
No data set associated with given data ID.
12
Either:
  • Invalid data set organization; must be partitioned or sequential.
  • Invalid parameter.
20
Severe error; unable to continue.