IEC291I 50D-rc, INCORRECT PARAMETER LIST SUPPLIED TO CLOSE MACRO, DCB ADDRESS = dcb
Explanation
The CLOSE parameter list contains an incorrect data control block (DCB) address.
The hexadecimal return code
explains the error:
- Return Code
- Explanation
- 1C
- The execute form of the CLOSE macro specifies MODE=31, but the parameter list specifies, or defaults to, MODE=24.
- 20
- The execute form of the CLOSE macro specifies MODE=24, but the parameter list specifies MODE=31.
In the message text:
- rc
- The return code.
- dcb
- The incorrect DCB address.
System action
The task ends.
Programmer response
If you generated the parameter list by using the list form of the CLOSE macro, change the mode specification to be consistent on both the MF=L and MF=E forms of the CLOSE macro. To have consistent modes, you may change either the list form or the execute form of the CLOSE macro.
Source
DFSMSdfp
Module
IGC00020
Routing code
11
Descriptor code
6