IEC221I 417-rc,mod,jjj,sss, ddname[-#],dev,ser,dsname(member)
Explanation
The error occurred during processing of a BSAM CLOSE macro instruction with a TYPE=T operand for a data set on a direct access device.
- rc
- Associates this message with system completion code 417 and with the return code.
- jjj
- The job name.
- sss
- The step name.
- ddname[-#]
- DDname (followed by a concatenation number if it is part of a concatenation and not the first DD statement in the concatenation).
- dev
- The device number.
- ser
- The volume serial number.
- mod
- The name of the module in which the error occurred.
- dsname(member)
- The data set name. Member name if specified.
- Return Code
- Explanation
- 04
- An I/O error occurred writing an updated format-1 DSCB during processing of a CLOSE macro instruction with a TYPE=T operand.
System action
The task is ended unless the error is to be ignored as specified in the DCB ABEND exit routine.
Operator response
TRACE=SYS,USR,SLIP
DCB=DIAGNS=TRACE
System programmer response
If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job.
Programmer response
If an I/O error has occurred, a defective volume or device may be the cause. Save the output from the failing job to aid in the analysis of the problem.
Rerun the job specifying a different volume or device. If a scratch volume was being used when the I/O error occurred, request a different volume. If that does not solve the problem, request a different device in the UNIT parameter of the DD statement. If a specific volume is needed, try requesting a different device in the UNIT parameter of the DD statement. Rerun the job.
Source
DFSMSdfp
Module
IFG0232D
Routing code
11
Descriptor code
6