IEC033I C37-rc,mod, jjj,sss,ddname[-#], dev,ser,dsname
Explanation
The error occurred when an input operation was requested. The data set was on a direct access device.
- rc
- Associates this message with system completion code C37 and with the return code.
- jjj
- The job name.
- sss
- The step name.
- ddname[-#]
- DDname (followed by a concatenation number if it is part of the concatenation and not the first DD statement in the concatenation).
- dev
- The device number.
- ser
- The volume serial number.
- mod
- The name of the module in which the error occurred.
- dsname
- The data set name.
- Return Code
- Explanation
- 04
- An end-of-volume condition occurred on a data set opened for input, but the next volume of the data set contained more than 16 extents.
- 08
- An end-of-volume condition occurred on a data set opened for input, but the next volume of the data set contained a type of split cylinder allocation that cannot be processed under MVS™.
System action
The task is ended unless the error is to be ignored as specified in the DCB ABEND exit routine. If the error is to be ignored, the system will attempt to close the DCB before returning to the user.
System programmer response
If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide all printed output and output data sets related to the problem.
Programmer response
Probable user error. The volume was created on z/VSE® or an earlier version of it and is not compatible with z/OS®. Either recreate the data set under z/OS or correct the problem by creating it under z/VSE so it is compatible.
Source
DFSMSdfp
Module
IFG0194C
Routing code
11
Descriptor code
6