After you install the SMP/E dialogs, you can change the default values they use.

When you select option 0 (SETTINGS) on the SMP/E Primary Option Menu, SMP/E displays panel GIM@PARM, which allows you to
  • Modify the values for allocating temporary SMP/E utility (SYSUTn) and SMP/E work (SMPWRKn) data sets . The options you specify are saved permanently in the ISPF profile pool for use later by other SMP/E dialog processes.
  • Specify a data set name to be used by SMP/E for the SMPPARM data set during background execution. The SMPPARM data set is used to define exit routines and specify allocation information used by SMP/E processing. If a data set name is specified on panel GIM@PARM, SMP/E generates an SMPPARM DD statement in all JCL jobs created by the SMP/E dialogs that invoke SMP/E.
GIM@PARM                      SMP/E DIALOG SETTINGS
===>

Reset to use SMP/E's default settings? ===> NO  (Yes or No)

Enter or verify the information below used to allocate temporary data sets.
These temporary data sets contain generated JCL jobs, output for jobs which
have completed execution, and MCS entries for viewing:

   UNIT   ===> SYSALLDA
   VOLUME ===>

Enter or verify the information below used to create DD statements in
generated JCL jobs:

   Space for SMP/E Utility Work data sets (SYSUTn):
             Block Size  Primary  Secondary
     SYSUT1     3120       380       760
     SYSUT2     3120       380       760
     SYSUT3     3120       380       760
     SYSUT4     3120        38       100

   Space for SMP/E Work data sets (SMPWRKn):
             Block Size  Primary  Secondary  Directory Blocks
     SMPWRK1    3120       364       380          500
     SMPWRK2    3120       364       380          500
     SMPWRK3    3120       364       380          500
     SMPWRK4    3120       364       380          500
     SMPWRK6    3120       364       380          500

   Unit for SYSUTn and SMPWRKn data sets:
     UNIT ===> SYSDA

   Data set name to use for SMPPARM.  If a name is specified, an SMPPARM DD
   statement will be generated.
     DSN  ===>

Enter or verify the information below used to allocate permanent SMPWRK3
data sets created and used by the SYSMOD Management dialogs:

   UNIT   ===>
   VOLUME ===>
   PREFIX ===>          (TSO Prefix is used if no prefix is specified)

To save the changes, press ENTER .