Procedure
- To Define an Ethernet attached session to the host, click
on 'Link Parameters.'
Figure 1. Customize communication screen
_______________________________________________________________
- Define the connection from the workstation to the OSA-ICC
server.
Figure 2. Telnet3270 screen
Enter the Host name or IP Address. The values in Host Name or IP
Address and Port Number were specified when defining the OSA-ICC server
configuration. For more information on defining your OSA-ICC server
Configuration see, Edit server configuration.
_______________________________________________________________
- Enter the LU or Pool Name. The value in LU or Pool Name
was specified when defining the group name in the session configuration.
_______________________________________________________________
- Enter the Port Number.
_______________________________________________________________
- Click OK on the Telnet3270 panel.
Note: It
is recommended that you select auto-reconnect. However, understand
that the drop session option for configuring an OSA-ICC will not work.
The auto-reconnect option will automatically reconnect your session
after you drop it. For more information on the drop session option,
see
Drop session.
_______________________________________________________________
Results
If you wish, use the Session Parameters option
in Customize Communication to set a screen size other than 24 by 80.
It is recommended that your screen size matches the operating system
screen size.
Note: 
OSA-ICC does not support dynamic
screen size terminal types (IBM_DYNAMIC). Using a client emulator
that supports this terminal type and configuring sessions with the
dynamic screen size may yield unpredictable and unexpected results
if the session is connected to OSA-ICC.

Clicking OK on the
Customize Configuration panel causes PCOMM to initiate the connection
to the host.
If the host session is not ready for communication,
the screen displayed will show your connection information for this
session. For example:
Figure 3. E - Capture —
[24x80]
Line 1: OSAE000 is the defined server name; 9.12.6.18:1024
shows the defined server address and port number.
Line 2:
session index; LCSS number; LPAR number (this is NOT the MIF image
ID we specified for the session, but it is related); logical CU number
(always 0); unit address for this device; LU name.
Line 3:
information for the connected processor.
When using IBM eNetwork
Personal Communications (PCOMM) for client TN3270E display sessions,
the following statement must be present in the PCOMM profile files
(xxx.WS) to ensure that printer WCC controls are ignored if sent by
the host:
[LT]
IgnoreWCCStartPrint=Y
If
this statement is not present in your PCOMM profile files you will
have to edit the xxx.WS files on your client PC with a PC text editor
to add the statement lines.