4FC
Explanation
The system detected an error in the processing following a program check interrupt. In an attempt to recover, supervisor control abnormally ended the task that experienced the program check.
System action
The system abnormally ends the program that experienced the program check. The system writes a logrec data set error record.
Operator response
If the system programmer asks for an SVC dump, set the following SLIP trap:
SLIP SET,COMP=4FC,ACTION=SVCD,END
System programmer response
Do the following:
- Find the original abend causing the problem in the system diagnostic work area (SDWA) in the logrec data set error record.
- Search problem reporting data bases for a fix for the problem. If no fix exists, ask the operator to set a SLIP trap to obtain an SVC dump. Contact the IBM® Support Center. Provide the SVC dump and the logrec data set error record.
Programmer response
Resubmit the job. If the problem recurs, contact the system programmer.
Source
Supervisor control