0B8
Explanation
A START, MOUNT, or LOGON command requested the creation or initialization of a new address space.
The system detected an error while processing the command. A hexadecimal reason code in register 15
explains the error:
- Code
- Explanation
- 04
- The command code in the command scheduling control block (CSCB) for the START, MOUNT, or LOGON command was incorrect.
- 08
- The system tried to build a task I/O table (TIOT) for the START, MOUNT, or LOGON processing, but failed.
- 0C
- While processing the START, MOUNT, or LOGON command, the system could not open or write to an internal reader.
- 10
- Processing to initialize the address space returned an undefined return code; the defined codes are 0 and 4.
- 14
- The newly created address space cannot be made nonswappable.
- 18
- To create the requested address space, the system issued a REQSWAP SYSEVENT macro. The macro failed.
- 1C
- The newly created address space did not initialize completely.
- 20
- Dynamic allocation or unallocation failed for an internal reader.
System action
The system:
- Ends the START, MOUNT, or LOGON command.
- Writes a dump.
- Writes a logrec data set error record.
- Issues messages. For a START or MOUNT command, the system issues message IEE824I.
System programmer response
If the problem recurs, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® support Center. Provide the dump and the logrec data set error record.
Source
Master scheduler