|
Function To perform the following functions: - Specify printer work selection and processing characteristics.
- Override a system request for a setup you are unable to fulfill.
- Start or stop tracing of the JES2 processor associated with the
specified printer.
One or more parameters on this command accepts wild cards.
Parameter descriptions will note that.
Syntax
>>-$T----------------------------------------------------------->
>--+-PRINTER-+--+-nnnnn--+-----------+-------------------+------>
'-PRT-----' | '- ---+-m-+-' |
| '-*-' |
| .-,----------------------------. |
| V | |
'-(------+-nnnnn-+--+-----------+---+--)-'
'-*-----' '- ---+-m-+-'
'-*-'
>--+---------------------------------+-------------------------->
'-| Selection limiting keywords |-'
>--+---------------------------+-------------------------------><
'-| Modification keywords |-'
Modification keywords
|--+----------------------+--+---------------------+------------>
'-,--Burst--=--+-No--+-' '-,--CCTL--=--+-No--+-'
'-Yes-' '-Yes-'
>--+------------------------------------------------------------------+-->
'-,--+-CHAR-+--+-nnnnn--+-----------+-------------------+--=--char-'
'-X----' | '- ---+-m-+-' |
| '-*-' |
| .-,----------------------------. |
| V | |
'-(------+-nnnnn-+--+-----------+---+--)-'
'-*-----' '- ---+-m-+-'
'-*-'
>--+--------------------------+--+--------------------------+--->
'-,--CKPTLINE--=--ckptline-' '-,--CKPTMODE--=--+-PAGE-+-'
'-SEC--'
>--+--------------------------+--+------------------------+----->
'-,--CKPTPAGE--=--ckptpage-' '-,--CKPTSEC--=--ckptsec-'
>--+------------------------------+----------------------------->
'-,--COPYMARK--=--+-CONSTANT-+-'
+-DATASET--+
+-DEFAULT--+
+-JOB------+
'-NONE-----'
>--+------------------------+--+----------------------+--------->
'-,--CReator--=--creator-' '-,--DEVFCB--=--devfcb-'
>--+--------------------------+--+--------------------+--------->
'-,--DEVFLASH--=--devflash-' '-,--+-C---+--=--fcb-'
'-FCB-'
>--+------------------------+----------------------------------->
'-,--+-FLASH-+--=--flash-'
'-O-----'
>--+---------------------------------------+-------------------->
'-,--Forms--=--+-form-----------------+-'
| .-,----------. |
| V (1) | |
'-(----------form-+--)-'
>--+-------------------------------------+---------------------->
'-,----/----FSAROLTR--+-=--+--+-Yes-+-'
'-^=-' '-No--'
>--+----------------+--+------------------------+--------------->
'-,--FSS--=--fss-' '-,--JOBname--=--jobname-'
>--+----------------------+--+---------------------+------------>
'-,--LIMit--=--+-m---+-' '-,--Mark--=--+-----+-'
+-m-n-+ +-No--+
'-m-*-' '-Yes-'
>--+---------------------+--+--------------------------+--------|
'-,--MODE--=--+-FSS-+-' '-,--+-MODIFY-+--=--modify-'
'-JES-' '-Y------'
Notes: - form can be coded up to 8 times
|--+----------------------------+--+------------------+--------->
'-,--NEWPAGE--=--+-ALL-----+-' '-,--NPRO--=--npro-'
+-DEFAULT-+
'-1-------'
>--+----------------------+--+---------------------+------------>
'-,--Pause--=--+-----+-' '-,--PLIM--=--+-m---+-'
+-No--+ +-m-n-+
'-Yes-' '-m-*-'
>--+-------------------------+---------------------------------->
'-,--PRESELCT--=--+-No--+-'
'-Yes-'
>--+----------------------------------------------+------------->
'-,--PRMode--=--+-prmode---------------------+-'
| .-,----------------. |
| V | |
'-(----+--------------+-+--)-'
| (1) |
'-------prmode-'
>--+------------------------+----------------------------------->
'-,--+-CLass-+--=--queue-'
'-Queue-'
>--+-----------------------------------------+------------------>
'-,--RANGE--=--+-low--------------------+-'
'-(--low--+---------+--)-'
'-,--high-'
>--+--------------------------------------------+--------------->
'-,--Routecde--=--+-routecde---------------+-'
| .-,------------. |
| V | |
'-(----+----------+-+--)-'
'-routecde-'
>--+--------------------+--+-----------------------------+------>
'-,--Sep--=--+-----+-' '-,--SEPCHARS--=--+-CURRENT-+-'
+-No--+ '-DEFAULT-'
'-Yes-'
>--+----------------------+--+-------------------------+-------->
'-,--SEPDS--=--+-----+-' '-,--SETUP--=--+-HALT---+-'
+-No--+ '-NOHALT-'
'-Yes-'
>--+-----------------------------+--+----------------------+---->
'-,--+-K-----+--=--+--------+-' '-,--TRace--=--+-No--+-'
'-SPACE-' +-DOUBLE-+ +-P---+
+-R------+ '-Yes-'
+-RESET--+
+-SINGLE-+
+-TRIPLE-+
+-1------+
+-2------+
'-3------'
>--+--------------------------+--+------------------------+----->
'-,--TRANS--=--+-DEFAULT-+-' '-,--TRKCELL--=--+-No--+-'
+-No------+ '-Yes-'
'-Yes-----'
>--+--------------------+--+-------------------------+---------->
'-,--+-T---+--=--ucs-' '-,--UCSVerfy--=--+-No--+-'
'-UCS-' '-Yes-'
>--+------------------+----------------------------------------->
'-,--UNIT--=--unit-'
>--+----------------------------------------+------------------->
'-,--Volume--=--+-volume---------------+-'
| .-,----------. |
| V | |
'-(----+--------+-+--)-'
'-volume-'
>--+----------------------+--+----------------------------+-----|
'-,--Writer--=--writer-' '-,--WS--=--+-ws-----------+-'
| .-,--. |
| V | |
'-(----ws-+--)-'
Notes: - prmode can be coded up to 8 times
Selection limiting keywords
|--+----------------------------------+------------------------->
'-,----/----Burst--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+---------------------------------+-------------------------->
'-,----/----CCTL--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+--------------------------------------+--------------------->
'-,----/----CKPTMODE--+-=--+--+-PAGE-+-'
'-^=-' '-SEC--'
>--+------------------------------------------+----------------->
'-,----/----COPYMARK--+-=--+--+-CONSTANT-+-'
'-^=-' +-DATASET--+
+-DEFAULT--+
'-JOB------'
>--+------------------------------------+----------------------->
'-,----/----CReator--+-=--+--creator-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------+------------------------->
'-,----/----DEVFCB--+-=--+--devfcb-'
+-^=-+
+->--+
'-<--'
>--+--------------------------------------+--------------------->
'-,----/----DEVFLASH--+-=--+--devflash-'
+-^=-+
+->--+
'-<--'
>--+--------------------------------+--------------------------->
'-,--+---/----C---+--+-=--+--fcb-'
'---/----FCB-' +-^=-+
+->--+
'-<--'
>--+------------------------------------+----------------------->
'-,--+---/----FLASH-+--+-=--+--flash-'
'---/----O-----' +-^=-+
+->--+
'-<--'
>--+---------------------------------------------------+-------->
'-,----/----Forms--+-=--+--+-form-----------------+-'
'-^=-' | .-,----------. |
| V (1) | |
'-(----------form-+--)-'
>--+----------------------------+------------------------------->
'-,----/----FSS--+-=--+--fss-'
+-^=-+
+->--+
'-<--'
>--+------------------------------------+----------------------->
'-,----/----JOBname--+-=--+--jobname-'
+-^=-+
+->--+
'-<--'
>--+---------------------------------+-------------------------->
'-,----/----Mark--+-=--+--+-----+-'
'-^=-' +-No--+
'-Yes-'
>--+--------------------------------------+--------------------->
'-,--+---/----MODIFY-+--+-=--+--modify-'
'---/----Y------' +-^=-+
+->--+
'-<--'
>--+----------------------------------------+------------------->
'-,----/----NEWPAGE--+-=--+--+-ALL-----+-'
'-^=-' +-DEFAULT-+
'-1-------'
>--+----------------------------------+------------------------->
'-,----/----Pause--+-=--+--+-----+-'
'-^=-' +-No--+
'-Yes-'
>--+-------------------------------------+----------------------|
'-,----/----PRESELCT--+-=--+--+-No--+-'
'-^=-' '-Yes-'
Notes: - form can be coded up to 8 times
|--+----------------------------------------------------------+-->
'-,----/----PRMode--+-=--+--+-prmode---------------------+-'
'-^=-' | .-,----------------. |
| V | |
'-(----+--------------+-+--)-'
| (1) |
'-------prmode-'
>--+------------------------------------+----------------------->
'-,--+---/----CLass-+--+-=--+--queue-'
'---/----Queue-' +-^=-+
+->--+
'-<--'
>--+--------------------------------------------------------+--->
'-,----/----Routecde--+-=--+--+-routecde---------------+-'
'-^=-' | .-,------------. |
| V | |
'-(----+----------+-+--)-'
'-routecde-'
>--+--------------------------------+--------------------------->
'-,----/----Sep--+-=--+--+-----+-'
'-^=-' +-No--+
'-Yes-'
>--+-----------------------------------------+------------------>
'-,----/----SEPCHARS--+-=--+--+-CURRENT-+-'
'-^=-' '-DEFAULT-'
>--+----------------------------------+------------------------->
'-,----/----SEPDS--+-=--+--+-----+-'
'-^=-' +-No--+
'-Yes-'
>--+-------------------------------------+---------------------->
'-,----/----SETUP--+-=--+--+-HALT---+-'
'-^=-' '-NOHALT-'
>--+-----------------------------------------+------------------>
'-,--+---/----K-----+--+-=--+--+--------+-'
'---/----SPACE-' '-^=-' +-DOUBLE-+
+-R------+
+-RESET--+
+-SINGLE-+
+-TRIPLE-+
+-1------+
+-2------+
'-3------'
>--+----------------------------------+------------------------->
'-,----/----TRace--+-=--+--+-No--+-'
'-^=-' +-P---+
'-Yes-'
>--+--------------------------------------+--------------------->
'-,----/----TRANS--+-=--+--+-DEFAULT-+-'
'-^=-' +-No------+
'-Yes-----'
>--+------------------------------------+----------------------->
'-,----/----TRKCELL--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+--------------------------------+--------------------------->
'-,--+---/----T---+--+-=--+--ucs-'
'---/----UCS-' +-^=-+
+->--+
'-<--'
>--+-------------------------------------+---------------------->
'-,----/----UCSVerfy--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------+----------------------------->
'-,----/----UNIT--+-=--+--unit-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------+-------------------------|
'-,----/----Writer--+-=--+--writer-'
+-^=-+
+->--+
'-<--'
Notes: - prmode can be coded up to 8 times
Parameters - nnnnn
- For PRT, the identifier of the local printer (1-32767)
to control. For R, the identifier of the
remote workstation (1-32767) that is attached to printer m (1-7).
- m
- The identifier
of the printer (1-7) that is attached to the remote workstation Rnnnnn (1-32767).
- ASIS={Y|N}
- Specifies
whether JES2 will send the print data to the remote printer without
suppressing extraneous ejects and adding an eject at the end of a
data set. This parameter should be specified as NO if the installation
wants to continue to suppress ejects and receive ejects at the end
of each print data set.
Note: This keyword applies only to remote
printers.
- Burst=[No|Yes]
- Specifies whether the printed
output from the indicated 3800 printer is to be burst into separate
sheets (Y) or is to be in continuous fanfold form (N).
- CCTL
-
CCTL={YES | NO}
Displays whether
(YES) or not (NO) JES2 places carriage control characters in the output
stream transmitted to this remote printer. If you specify CCTL=NO,
JES2 neither compresses (COMPRESS=NO) nor compacts (COMPACT=NO) data,
and standard character string (SCS) control characters are not placed
in the output string.
Note: The CCTL= parameter applies to
remote printer and SNA devices only.
- C|FCB={xxxx|RESET}
-
- xxxx
- The identifier (1– to 4–alphanumeric or special character ($ #
@)) of the carriage control tape for a printer without a forms control
buffer (FCB) feature, or the FCB image for a printer having the FCB
feature. If you specify an FCB image, it must be available in SYS1.IMAGELIB.
If loading is required for Rnnnn.PRm, it must be done by the operator
at the JES2 RJE workstation, unless the workstation has FCB-loading
capability.
- RESET
- Specifies that a 3800 printer or a printer running under the control
of a functional subsystem (FSS mode) is to construct a 6 lines per
inch FCB based on the forms loaded in the printer. For a 3800 (and
other printers) in FSS mode, JES2 uses the FCB specified in the PROC
that starts the FSS. RESET can be used to correct the problem indicated
by the $HASP180 load error message.
Note: - When you explicitly set the C= parameter for the 3800 printer,
the specified value is used as the installation's default FCB image
for SYSOUT data sets which do not specify the FCB= parameter through
JCL.
- If you have received the $HASP180 load error message indicating
an FCB image error, specify the C= parameter to correct the problem.
- CKPTLINE=ckptline
- Specifies the maximum number of lines
(0-32767) in a logical page. JES2 uses this value, the CKPTPAGE=
parameter, and the LINECT= parameter on PRINTDEF, to determine when
to take output checkpoints as follows:
JES2 compares the "line
count values" you specified on the PRINTDEF LINECT= and PRT(n) CKPTLINE=
parameters and then always uses the lesser value.
Checkpoint
Interval = line count * CKPTPAGE (if non-zero)
where line count is either:
The size of a logical page is also defined as the number
of lines printed until: - A channel skip is encountered
- The line count specified by the LINECT= parameter on the PRINTDEF
statement, the /*JOBPARM control statement, the JCL OUTPUT statement,
or the JOB statement accounting field has been exceeded.
Note: This operand is ignored if specified for a printer
under the control of a functional subsystem. The functional subsystem
does its own physical and logical pages checkpoint based on the CKPTPAGE
and CKPTSEC values passed to it from JES2.
- CKPTMODE={PAGE|SEC}
- Specifies whether the functional subsystem is to take checkpoints
based on page count or elapsed time.
Note: This operand is valid
for printers under the control of a functional subsystem only, not
those under the control of JES2.
- PAGE
- The functional subsystem uses the checkpointing interval specified
by the CKPTPAGE operand.
- SEC
- The functional subsystem uses the checkpointing interval specified
by the CKPTSEC operand.
Note: The installation should set the values for
CKPTSEC and CKPTPAGE so they are best for the printer; then control
which checkpoint method to use, either SEC or PAGE, by changing the
CKPTMODE parameter.
- CKPTPAGE=ckptpage
- The number (1-32767) of logical pages for non-page
mode printers and physical pages for page-mode printers to be printed
before each output checkpoint is taken. This parameter and CKPTLINE
control the amount of checkpoint activity to spool.
Note: - When you use the K=(1|2|3|R) operand for a data set that is printing
on a 3800-3 printer operating in FSS mode, the forced spacing is reset
either at the end of that data set, or when you issue a $T PRTnnnn,CKPTPAGE=nnnnn
command while this data set is printing. If you issue the $T PRTnnnn,CKPTPAGE
command and forced spacing is still desired, you must include the
K=(1|2|3|R) operand.
- The CKPTPAGE parameter should be set to a low value for slow printers
and a high value for faster printers such as the 3800 to prevent the
occurrence of excessive checkpoint cycles for faster devices.
- CKPTSEC=ckptsec
- The number (0-32767) of seconds to elapse before each
output checkpoint is taken. This parameter is valid only for a printer
under control of a functional subsystem.
- CMPCT=[YES|NO]
- For SNA RJE workstations only, specifies whether (YES) or not (NO) this remote printer has compaction
capabilities. If it does and the corresponding RJE workstation definition
(RMT(nnnn) ) specifies COMPACT=YES, JES2 forces this remote printer
to use compaction.
If you specify CMPCT=YES, JES2 forces compression
of the data (COMPRESS=YES). If you specify CMPCT=NO, JES2 turns off
compaction, even if it is specified on the RJE workstation definition.
Note that the CMPCT= parameter: - Applies only to remote printers
- Can be changed only when the printer is inactive
- Must be specified as NO if CCTL=NO
- COMPACT|Z=compact
- Specifies the compaction table number or the 1 to 8 character compaction
table name that must be defined through a COMPACT initialization statement.
Note: The COMPACT= parameter can be changed only when the printer
is inactive.
- COMPRESS=[No|Yes}
- Specifies whether (YES) or not (NO) this remote printer has compression/expansion
capabilities.
If you specify COMPRESS=YES and the corresponding
RJE workstation and LINE(nnnn) initialization statements specify COMPRESS=YES,
JES2 forces this remote SNA printer to use compression. If you specify
COMPRESS=NO, JES2 turns off compression, even if the corresponding
RJE workstation specifies COMPRESS=YES.
Note that the COMPRESS=
parameter: - Applies only to remote printers
- Can be changed only when the printer is inactive
For SNA RJE workstations only: - Must be specified as NO if CCTL=NO
- Sets on the corresponding bit setting in the RJE BIND if COMPRESS=YES.
- COPYMARK={CONSTANT|DATASET|DEFAULT|JOB}
- Specifying DATASET or JOB causes copy marks (SYSOUT
separation indicator markings) to be incremented on a data set level
or on a JOE level, respectively. Copy marks are not incremented when
you specify CONSTANT.
Note: The COPYMARK parameter applies to
FSS-controlled devices only.
- CReator=jccccccc
- Specifies the 1– through 8–character userid that creates the SYSOUT
data sets to be processed. You can also specify wild cards on this
parameter. See Using wildcards for additional
information.
- j
- An alphabetic character (A-Z) or any of the special characters
($, #, or @).
- ccccccc
- Any combination of EBCDIC characters except a comma, a right parenthesis,
or an equal sign.
- DEVFCB=devfcb
- Specifies the
default FCB attribute JES2 uses when FCB= is not coded in the job's
JCL. (JES2 does not validate the existence of the FCB name in SYS1.IMAGELIB.)
Specifying RESET sets the default FCB attribute to null.
Note: 3800
printers use the FCB specified on the PRT initialization statement.
- DEVFLASH={xxxx|NONE}
- Specifies the name of the device default forms FLASH ID.
- xxxx
- The identifier (1 to 4 alphanumeric or special ($ # @) characters)
of the forms FLASH ID for the specified 3800 printer. This forms FLASH
ID is used for jobs selected by this printer that do not have FLASH=
explicitly coded in the job's JCL.
- NONE
- The forms FLASH ID is unspecified (the value is set to asterisks).
Note: The printer must be drained before
the DEVFLASH parameter can be used to modify the default forms FLASH
ID.
- EJECT=Yes | No
- Specifies whether JES2 sends a page eject to a remote printer
on the printer's first use following the start of an RJE session,
depending upon the assumed position of the printer. JES2 assumes that
the remote printer is not positioned at the top of a page on the first
use after JES2 is started, restarted, or after an RJE session fails
and the remote printer is not at the top of a page.
EJECT=Yes causes
JES2 to send a page eject when the remote printer is not assumed to
currently be at the top of a page. Use this parameter value when the
output is destined for a physical printer.
EJECT=No ensures
that a print stream never begins with a page eject. Workstations that
write SYSOUT to media other than paper can use this parameter to create
files that do not contain page ejects in the first line.
You
can change this parameter after initialization using a $T command;
however, the change takes effect at the beginning of the next RJE
session, regardless of whether printing has begun.
- FCBLOAD={YES|NO}
- Specifies whether (YES) or not (NO) JES2 provides the forms control
buffer (FCB) for this printer.
This parameter works only for SNA
printers or a 3211 printer attached to a multileaving workstation
with the text-transparency (TRANSPAR=YES on both the LINE(nnnn) and
the RJE workstation definitions) feature.
For an SNA RJE workstation,
the FCBLOAD= parameter uses only one stop for each channel, for a
maximum of 12 stops.
Note that the FCBLOAD= parameter: - Applies to remote printers only
- Can be changed only when the printer is inactive
- Is forced to NO if SETUP=PDIR on the corresponding RJE workstation.
- Is limited to the line length specified by the PRWIDTH= parameter
minus 2 for this printer.
- FLASH|O={xxxx|RESET|NONE}
- Specifies the name of the active
(current) forms FLASH ID.
- xxxx
- The identifier (1– to 4–alphanumeric or special ($ # @) characters)
of the forms FLASH ID for the specified 3800 printer. This forms FLASH
ID is used for jobs selected by this printer only when the job has
explicitly coded the identical forms FLASH ID in the job's JCL, or
if the FLASH ID is the same as the DEVFLASH ID on the DEVFLASH parameter.
- RESET
- The current forms FLASH ID is unspecified (the value is set to
asterisks).
- NONE
- The current forms FLASH ID is unspecified (the value is set to
asterisks).
- Forms=form
- The 1– to 8–alphanumeric or special
($ # @) character name of the forms that are loaded into this printer.
You can also specify wild cards on this parameter. See Using wildcards for additional information.
Note: You
can specify 1 through 8 forms for local printers. F=(STD1,STD2)
- FSAROLTR ={YES|NO}
- Specifies whether the internal rolling trace for an FSS printer is
activated or deactivated.
- FSS=accccccc
- Specifies a 1– to 8–character
functional subsystem name that supports a page-mode printer. If an
FSSNAME is not defined on an FSS initialization statement, the functional
subsystem name assigned on this statement will cause the generation
of a default FSS initialization statement. The FSS statement then
defines (by default) the FSSNAME and PROCname specified here.
Note: - This parameter must be specified if MODE=FSS is specified for
this PRT(nnnn) command.
- You must also specify UNIT= if this PRT(nnnn) command defines
a 3827 or 3835 printer.
- HONORTRC{YES|NO}
- Specifies whether the TRC=Yes/No parameter specified on the job's
OUTPUT JCL statement will be honored or not honored for a given JES
mode printer.
- JOBname=jobname
- The 1– to 8–character name of jobs whose output is to be selected
by this printer. you can also specify wild cards on this parameter.
See Using wildcards for additional information.
A null parameter of (JOBNAME=) specifies that jobname is not a criterion
for output selection.
- K|SPACE=[DOUBLE|R|RESET|SINGLE| TRIPLE|1|2|3]
- Specifies the spacing for printed output.
- {1|2|3|SINGLE|DOUBLE|TRIPLE}
- The printer is to single (1), double (2), or triple (3) space
the printed output, regardless of the problem program specifications.
When the end of the data set is encountered or when a $T PRTnnnn,
K=R command is entered, the printer reverts to problem program specifications.
- R|RESET
- The printer is to be reset to the problem program-specified spacing.
Note: When you specify the K=(1|2|3|R) parameter
for a data set that is being processed on a printer operating in FSS
mode, the forced spacing is reset either at the end of that data set,
or when you issue a $T PRTnnnn,CKPTPAGE=nnnnn command while that data
set is printing. If you issue the $T PRTnnnn,CKPTPAGE command and
forced spacing is still desired, you must include the K=(1|2|3|R)
operand.
- LIMit={m|m-n|m-*}
- Specifies the lower and upper
limits (in records) for the size of output that is to be selected
by this printer.
For both variables m and n, you
can specify a range of values 0-4294967295. m and n can be equal. If they are not equal, n must be larger than m.
If you code only m,
that value becomes both the lower and upper limit. If m-* is
specified, the upper limit is set to the default value of 4294967295.
Note: If the printing of an output group is interrupted, JES2 compares
the original size of the output (the number of lines prior to any
printing rather than the lines remaining) with the LIM= specifications.
- LRECL=nnn
- For SNA RJE workstations only, specifies the logical record length (1-255) of data transmitted
to this remote printer. Do not include carriage control characters
(CCTL) when calculating the value of LRECL. The LRECL value cannot
exceed the printer width specified during RMT generation through the
&PRTSIZE RMT generation statement for this RJE workstation.
Note that the LRECL= parameter: - Applies to remote printers only
- Can be changed only when the printer is inactive
- Can be used in place of the PRWIDTH= parameter to specify record
sizes for records destined for remote printers.
- Mark=[No|Yes]
- Specifies for the 3800 printer,
whether the edge of the separator page is to be marked.
Note: If
the printer is under control of a functional subsystem, specifying
N suppresses marking on the separator page, but produces a unique
mark on the carrier strip (that is, the punched, perforated page edge).
- MODE={FSS|JES}
- Specifies whether the printer
is under control of a functional subsystem (FSS) or JES2.
Note: - When a change of control mode is desired for a printer that is
active (that is, output is being printed), you must enter a $P PRTnnnn
command for the printer and wait for it to drain before entering this
command. The $HASP097 message indicates when the draining process
is complete. If the printer is not drained before entering this command,
JES2 ignores the command.
- JES2 ignores the MODE specification if the printer was not defined
as a functional subsystem device (using the FSS= parameter) on the
PRTnnnn initialization statement. (If a device was mistakenly defined
as being a functional subsystem device, JES2 honors the MODE specification,
but incorrect output results.)
- The MODE specification is not supported for remote printers.
- MODIFY | Y=modify
- Specifies the 1 to 4 character identifier of the copy modification
module for the specified 3800 printer.
- NEWPAGE={1|ALL|DEFAULT}
- Specifies how a ‘skip to channel' is counted as a new page.
- 1
- Specifies that JES2 will treat only skip-to-channel-one as a new
page.
- ALL
- Specifies that JES2 will treat skip-to-any-channel as a new page.
- DEFAULT
- Specifies that the NEWPAGE specification on the PRINTDEF initialization
statement will be used.
- NPRO=npro
- The non-process runout (NPRO) time interval, in seconds
(0-3600). This time interval is used to control the amount of time
that an FSS-controlled printer is idle with output in the paper path
but not at the stacker. When the time interval expires, the functional
subsystem directs the printer to force the output to the stacker.
NPRO=0 specifies that a timer-based NPRO is not used.
Note: The NPRO parameter has no effect on cut-sheet page printers (for
example, the 3820).
- Pause=[No|Yes]
- Specifies whether the local printer is to pause between data sets.
If you specify Y, you can restart the device by changing it from
a not-ready to a ready state or by entering a $S PRTnnnn command.
Note: This operand has no effect for a printer under control of a
functional subsystem.
- PLIM={m|m-n|m-*}
- Specifies the lower and upper
limits (in pages) for the size of output that is to be selected by
this printer.
For both variables m and n, you can
specify a range of values 0-4294967295. m and n can be equal. If they are not equal, n must
be larger than m.
If you code only m, that value
becomes both the lower and upper limit. If m-* is specified,
the upper limit is set to the default value of 4294967295. Note: - Normally the PLIM should only be used with functional
subsystem printers capable of printing page mode data.
- If the printing of an output group is interrupted, JES2 compares
the original size of the output (the number of pages prior to any
printing rather than the pages remaining) with the PLIM= specifications.
- When PLIM is specified (non–zero value) for r(nnnn).pr(m)
PRMODE of PAGE will be of significance for remote printers and WS
criteria for remote printers.
- PRESELCT={Yes|No}
- Specifies whether JES2 preselects an output group for a device.
Specifying PRESELCT=N makes output groups selectable by any device.
Y is the default.
Note: - The PRESELCT operand is valid only when the printer is under control
of a functional subsystem.
- When PRESELCT=YES is specified, a printer that is busy printing
one output group may preselect another large output group. The operator
will be unable to change the destination of the second output group
to another printer once the output group is preselected.
- PRMode=(mode1[,...mode8])
- The SYSOUT mode(s)
(1 to 8 alphanumeric characters) to be processed by this printer.
You can specify up to 8 SYSOUT modes for a single printer. You can
also specify wild cards on this parameter. See Using wildcards for additional information. Multiple
entries must be separated by commas and the list must be enclosed
in parentheses. If all processing modes are selectable by this printer,
specify a null parameter of PRMODE=(). You must specify the empty
parentheses.
Note: For a list of valid process-mode values, see your
system programmer.
- PRTnnnnn
- The identifier
of the local printer (1-32767) that is controlled.
- PRWIDTH=nnn
- Specifies the number (1-255) of characters printed on one line. The
PRWIDTH value cannot exceed the printer width specified during RMT
generation through either the &PRTSIZE or the &PRFOTLW RMT
generation statements for this RJE workstation.
Note that the
PRWIDTH= parameter: - Applies to remote printers only
- Can be changed only when the printer is inactive.
- Should not exceed 120 for printers attached to a BSC terminal
defined as a 2770 without the buffer-expansion feature.
- CLass|Queue=c1[...c36]
- The output class(es) (A-Z, 0-9) the printer is to process. You can
specify up to 36 output classes.
- Routecde=routecde
- Specifies up to four internal route codes to be assigned to this
printer. If more than one route code is specified, enclose the list
in parentheses. You can also specify wild cards on this parameter, but wildcard specifications are allowed on this parameter
for userids only. See Using wildcards for
additional information. For specification requirements, see Route codes.
Note: - JES2 does not allow remote printers to change Routecde= to another
destination or to delete Routecde from the work selection list.
- NODENAME=REQUIRED on the DESTDEF initialization statement will
cause JES2 to require that a userid be prefixed with a node name.
If destid is specified alone, it refers to both the
node and the remote. - Ummmm
- Indicates that output for special local routing is selected. The
special routing numbers range from 1 to 32767.
Routing to a remote device can be specified in
any of the following ways: - LOCAL|ANYLOCAL
- Rnnnn
- destid
- userid
- LOCAL|ANYLOCAL
- Indicates routing to a local device.
- Rnnnn
- Indicates routing to the specified remote device. Rnnnn can also
be specified as RMnnnn or RMTnnnn. The value specified for nnnn can
range from 1 to 32767.
- destid
- Indicates routing to a destination at the local node.
- userid
- Indicates routing to a valid TSO userid. Generic userids are
also valid. A generic userid is a userid that ends in an asterisk
(*), and refers to all userids that begin with the characters preceding
the *. Note that the * can only be specified in the last position
of the userid.
Note: This command accepts Nnnnn or an installation-defined
name as the value of the R= parameter; however, the resulting internal
route code must be for the local node.
- Rnnnnn.PRm
- The
identifier of the remote printer (1-32767) that is controlled.
- RANGE={Jnnnnn|Snnnnn|Tnnnnn} [-nnnn]
- Specifies the range (1-65534)
of batch jobs (J), started tasks (S), or time sharing users (T) whose
output is to be selected by this printer. If you code this parameter,
you can specify one or two values:
- If you specify one value, that value becomes both the low and
the high end of the range.
- If you specify two values, the first value is the low end of the
range and the second value the high end. The two values can be equal.
If they are not equal, the second value must be larger than the first
value.
- SELECT={PRINTnn|EXCHnn|BASICnn}
- Specifies the
device type (PRINT, EXCH, or BASIC) and the device subaddress (0 -
14) to which JES2 sends output for this remote device.
The SELECT=
options: - PRINTnn
- Sends output to the remote printer.
- EXCHnn
- Sends output to an exchange diskette service.
- BASICnn
- Sends output to a basic exchange diskette service.
The value nn specifies the device number
(1 to 15; subaddress 0 to 14). If you do not specify the nn value, JES2 provides a default of any available device of the type
specified (subaddress=15).
Note that the SELECT= parameter:
- Applies to remote printers only
- Can be changed only when the printer is inactive
- Is ignored for BSC devices
- Should specify a BASIC type only if CCTL=NO and the LRECL= value
does not exceed 128.
- Sep=[No|Yes]
- Specifies whether JES2-supplied
separator pages are to be placed between output groups. If you specify
N, the JESNEWS data set is not printed. If this is a remote printer,
specifying N also suppresses the transmission of operator messages
to the RJE workstation, with the exception of the $HASP190 setup message.
Note: If you specify Sep=Y, but SEPPAGE=(LOCAL=NONE) (for local printers)
or SEPPAGE=(REMOTE=NONE) (for remote printers) was specified on the
PRINTDEF initialization statement or using the $T PRINTDEF command,
default JES2 separator pages are not produced. If you specify Sep=N,
a user created separator page (made in Exit 1) is not suppressed.
- SEPCHARS={CURRENT|DEFAULT}
- Specifies the character arrangement table to use for separator pages
printed on the 3800 printer. The NUICS parameter on the PRINTDEF
initialization statement defines this value at system initialization.
- CURRENT
- Specifies use of the character arrangement table loaded in the
3800. The first character arrangement table is used if the installation
default is not loaded.
- DEFAULT
- Specifies use of the installation default character arrangement
table. If not already loaded, this parameter specifies that this
table be loaded before printing the separator pages.
- SEPDS=[No|Yes]
- Specifies whether a header separator
page is to be produced for each copy of each data set within an output
group. If the printer is running under JES2, specifying Y causes JES2
to invoke EXIT 15 (output data set/copy separators), if enabled, to
generate separator pages. For printers under control of a functional
subsystem, SEPDS is supported with a default separator page.
- SETUP={HALT|NOHALT}
- Specifies whether JES2 is to halt the printer and
issue the $HASP190 message requesting the operator to verify the output
control specifications when the output requirements for a particular
job differ from the output characteristics specified for the printer.
(If halted, the printer must be restarted using the $S command.)
- SUSPEND=[No|Yes]
- Specifies whether a remote printer can (No) or cannot (Yes) use the
printer-interrupt feature which allows the remote operator to interrupt
printing for the transmitting of jobs or JES2 commands to this JES2
system.
Note: - Applies only to printers connected to BSC hardware terminals.
- This parameter can only be changed when the printer is inactive.
- T|UCS=ucs
- For
impact printers, T= specifies the identifier (1 to 4 alphanumeric
or special ($ # @) characters) of the print train character set that
is mounted on the specified printer. The identifier must be available
in SYS1.IMAGELIB and the indicated printer must have the universal
character set (UCS) feature. If loading is required for Rnnnn.PRm,
it must be done by the operator at the JES2 RJE workstation.
For
3800 printers, T= specifies both the identifier (1 to 4 alphanumeric
characters) of the print train character set that is mounted on the
printer and the installation's default character set for SYSOUT data
sets that do not specify the UCS= parameter through JCL. This identifier
must be available in SYS1.IMAGELIB. Note: - If you specify an invalid identifier, JES2 bypasses the UCS loading
procedure and issues the $HASP190 setup message so the operator can
specify a valid image.
- If you specify T=0 or a zero value was specified for the UCS parameter
on the PRINTDEF initialization statement, JES2 does not load the UCS
buffer.
You would want to nullify the UCS operand when running
a printer in FSS mode if you wish to use the default character set
specified in the FSS procedure used to start the printer.
- This parameter is only valid for a 1403 printer that has the UCS
feature.
- TRKCELL={No|Yes}
- Specifies whether data sets that belong to a SYSOUT class
with the track-cell characteristic are read from the spool in one
operation. The TRKCELL parameter on the SPOOLDEF initialization statement
specifies the number of records in the track cell. If you specify
NO, one record is read from the spool for each despooling operation.
- TRace={No|Yes|P}
- Specifies whether tracing is
to be activated or deactivated for this print processor. This operand
requires system authority.
- No
- Tracing is disabled.
- P|Yes
- Tracing is activated if trace IDs 11, 12, 14, and 15 are currently
enabled.
Note: Trace IDs 11, 12, 14, and 15 may be enabled either
at initialization on the TRACE(n) statement or using the $S TRACE(n)
command.
- TRANS={Yes|No}
- IF
MODE=JES, the TRANS= parameter on this statement affects data translation:
- If TRANS=YES, JES2 translates each line of output sent to the
device regardless of the device type or the setting of the TRANS=
parameter of the PRINTDEF initialization statement.
- If TRANS=NO, JES2 does not translate output sent to the device
regardless of the device type or the setting of the TRANS= parameter
on the PRINTDEF initialization statement.
- If TRANS= is omitted and the PRINTDEF initialization statement
specifies TRANS=YES, and the device is either a local 1403 or a remote
printer, JES2 translates each line of output sent to the device.
Otherwise, JES2 does not translate output sent to the device.
- UCSVerfy={No|Yes}
- Specifies whether (YES) or not (NO) UCS verification processing is
performed when a UCS image is loaded for 4245 and 4248 printers. UCS
images are loaded on these printers only when required for print processing,
not in response to a $T PRT command that specifies a change in UCS
setup. This parameter can be modified through a JES2 warm start.
- YES
- Provides UCS verification and causes the band image to be displayed
to the 4245 and 4248 printers.
- NO
- Suppresses the image display.
- UNIT={devnum|/devnum}
- Specifies
no value or a 3-digit or 4-digit hexadecimal device number. Device
numbers can be specified by any of the following formats:
UNIT= (to specify a null value)
UNIT=ddd
UNIT=dddd
UNIT=/ddd
UNIT=/dddd
where ddd and dddd represent the device numbers. A slash (/) can optionally precede the device number (for compatibility
with other commands that require a slash to denote a 4-digit device
number).
Note: You cannot use $T PRTnnn to remove
the UNIT specification for a JES mode printer.
- VOLUME=(v1[,...v4])
- The volume serial
(5-6 characters) of a volume containing a spool data set. Only the
output of jobs which reside on one or more of the specified volume(s)
are to be selected by this printer. You can specify up to 4 volumes.
Multiple entries must be separated by commas and the list must be
enclosed in parentheses. A null parameter of VOLUME=() specifies that
volume is not a criterion for output selection. You must specify
the empty parentheses.
- Writer=xxxxxxxx
- The 1 to 8 alphanumeric
or special ($ # @) character writer name assigned to this printer.
You can also specify wild cards on this parameter. See Using wildcards for additional information. A null parameter
of (W=) specifies that no writer name is assigned to this printer.
Note: If you do not assign a writer name to the printer, and Writer
is specified as an exact match criteria in the work selection (WS)
list, the printer selects only output groups without a writer name.
- WS=ws
- Specifies the work selection criteria for this printer.
Using any combination of user and JES2-defined criteria, you may specify
a maximum of 19 criteria in the WS= list. Criteria that are not specified
are not considered during output selection although JES2 does use
them to determine setup requirements. Multiple entries must be separated
by commas and the list must always be enclosed in parentheses (even
if only one criterion is specified).
The general rules for
specifying a printer work selection list are: - One slash (/) can precede or follow one of the selection criterion.
Criteria placed before the slash must be matched exactly if the work
is to be selected. Criteria placed after the slash do not have to
match exactly except in the following cases:
- Queue
- Routecde
- PRMode
- Volume
Table 1 defines each criterion
when placed either before or after the slash.
- Queue, Routecde, PRMode, and Volume can be specified as multiple
values on the output device statements. Placing these criteria before
the slash in the WS= list, indicates a left to right priority order
of multiple values, if multiple values have been specified. Placing
these criteria after the slash indicates no priority order of multiple
values, but a match is still required.
- The order of those criteria specified after the slash indicates
the priority (highest to lowest, in left to right order) in which
JES2 attempts to match them.
- Specifying a minus sign (-) before a criterion causes that criterion
to be removed from the list.
Note: An invalid operand message ($HASP650)
is issued if an error is found in the WS operand, that is, if you
try to remove a criterion that is not there. For example, if you
enter $tprt1,ws=(-o), you get the $HASP650 message because ‘o'
(forms overlay) is not in the current work selection list for printer1.
- Specifying a criterion that is not currently specified in the
list adds it to the end of the list either before or after the slash,
depending on the placement of the slash in the command. If the slash
is omitted from the command, JES2 assumes that the slash is at the
end of the command.
- For all exact match criteria, if the output matches the device
for a specific criterion, but the output specifies demand (DMND) setup,
the match is not considered an exact match and the output is not selected
because demand setup indicates that the characteristics do not remain
the same throughout the output group.
To print demand (DMND) setup
output, the work selection criteria specified for the printer that
is referenced by DMND must be removed from the list.
- If the device is a remote printer, route code (R=) must be specified
in the work selection list.
- The LIMit subparameter has no effect as a work selection value
for files received from a node that does not provide a page count
for its files. For more information, refer to the sending node's
reference documentation.
- In general, the smaller the work selection list the less the placement
of certain criteria within the list affects the work selection. Job
output elements are queued to the class queues by route code, then
priority. This information should be used to tune the work selection
list to optimize performance.
- X|CHAR=id
- The identifier(s), 1 to 4 alphanumeric characters, available in SYS1.IMAGELIB,
for the first through fourth character arrangement tables, respectively,
to be used in the specified 3800 printer.
Note: You should specify
this operand only if you have received an error message indicating
that a character arrangement table was not found.
Authority Required This command requires device and system authority. The description of the $T RDRnn
command explains how to ensure that the authority of the appropriate MVS™ system command group is assigned.
This command requires update security access authority. For a description of assigning
command input authority, see z/OS JES2 Initialization and Tuning Guide, SA32-0991.
Processing Considerations - The setting of forms, trains, carriage controls, or FCB image
is valid only when the specified device is inactive, pausing, or awaiting
operator action (halted).
- You should either issue a $P PRTnnnnn command and wait for the
device to drain before entering the $T command, or issue the $T command
while the system is waiting for forms to be loaded. Because JES2 does
not issue a setup message for a printer that does not require operator
intervention to change the carriage control, the requested image cannot
be overridden unless there is an error.
- If you are uncertain of the controls in effect, enter the $D PRT
command or the $D U command for the printer in question.
Scope Single member. This command
will be in effect for this member only. There is no need to have this
command issued to all members of the MAS.
Messages The $HASP603 message displays
the status of the specified printer and its current characteristics.
The $HASP003 rc=65 message indicates that the device type specified
through the UNIT= parameter does not match the defined JES2 device
information.
The $HASP003 rc=66 message indicates that the
device type specified through the UNIT= parameter does not exist.
ExamplesBecause of the number of examples
presented and the length of the resulting message, $HASP603 is shown
only for the first example. 1 $t prt101,unit=0b08,fss=psf1,mode=fss
$HASP603 PRT101 UNIT=0B08,STATUS=DRAINED,BURST=NO,CKPTLINE=0,
$HASP603 CKPTMODE=PAGE,CKPTPAGE=100,CKPTSEC=0,
$HASP603 CREATOR=,DEVFCB=,DEVFLASH=****,FCB=6080,
$HASP603 FORMS=(STD,,,,,,,),FSS=PSF1,HONORTRC=YES,
$HASP603 JOBNAME=,LASTFORM=STD,LIMIT=(0-*),
$HASP603 COPYMARK=DATASET,MARK=YES,MODE=FSS,
$HASP603 NEWPAGE=DEFAULT,NPRO=5,PAUSE=NO,PLIM=(0-*),
$HASP603 PRESELCT=YES,PRMODE=(LINE,PAGE),QUEUE=V,
$HASP603 RANGE=(J1,999999),ROUTECDE=(LOCAL),SEP=YES,
$HASP603 SEPCHARS=DEFAULT,SEPDS=NO,SETUP=HALT,SPACE=,
$HASP603 TRACE=NO,TRANS=DEFAULT,TRKCELL=YES,UCS=GB12,
$HASP603 UCSVERFY=NO,VOLUME=(,,,),WRITER=,
$HASP603 WS=(W,Q,R,PRM,LIM,UCS,FCB/F,P),FSAROLTR=NO
JES2 loads FSS line-mode printer 101 at address 0B08 of
the local installation. 2 $t r1.pr1,select=basic8,cctl=yes,lrecl=128
JES2 sends SYSOUT destined for this remote printer to
a basic exchange diskette service and places carriage control characters
in the SYSOUT stream transmitted to remote printer 1. 3 $t prt2,f=228,prmode=page,t=pn
JES2 loads the forms numbered 228 and a PN train into
local printer 2. Printer 2 now selects only those data sets that
specify forms 228 and a PRMODE of PAGE. 4 $t prt6,k=r,mark=y,y=cm01,x1=gf10,x2=fm15
JES2 resets local printer 6 to the program-specified spacing.
Printer 6 now uses: - Edge marking for separator pages
- Copy modification module CM01
- Character arrangement tables GF10 and FM15.
5 $t prt3,q=acb,r=1,ws=(q,r/),sep=y,pause=y,
setup=nohalt
Printer 3 prints all output in classes A, C, B, (in that
order) that was to be routed to the local device with routing set
to 1. As part of its processing, printer 3 pauses between data sets
and places separator pages between output groups. SETUP=NOHALT specifies
that printer 3 does not halt and issue the $HASP190 message if a job's
output specifications do not match those of the printer. 6 $t r8.pr2,tr=y
JES2 traces the logic of the JES2 processor associated
with remote printer 2 at workstation 8. 7 $t r2.pr1,r=(r7,r8,r9,r10),devfcb=wxyz
If Routecde is specified in the work selection list, remote
printer 1 at RJE workstation 2 processes only the output that was
destined for RJE workstations 7, 8, 9, or 10. JES2 uses “wxyz” as
the default FCB attribute if C=wxyz has also been specified. In contrast
with the second line of the $HASP603 message shown in the first example:
C=STD1,STD
the $HASP603 message now displays: C=wxyz,DEFAULT
Note that DEFAULT does not appear in the message if the
current FCB is not the specified default FCB (devfcb=wxyz, in this
example). For a complete description of the resulting message depending
on the C= and DEVFCB= settings, see $HASP603 in z/OS JES2 Messages, SA32-0989.
8 The current work selection
list for printer1 is: WS=(w,q,r,pmd,lim/f,t,c,p)
To remove w from the list, enter: $tprt1,ws=(-w) and the result is: WS=(q,r, pmd,lim/f,t,c,p)
To remove w from the list and add burst b as an exact match criterion, enter: $tprt1,ws=(-w,b/) and
the result is: WS=(q,r,pmd,lim,b/f,t,c,p)
To move pmd after the slash and switch the positions
of q and r, enter: $tprt1,ws=(r,q,lim/pmd) and
the result is: WS=(w,r,q,lim/f,t,c,p,pmd)
Table 1. Printer Work Selection
CriteriaCRITERION |
BEFORE SLASH (/) |
AFTER SLASH (/) |
---|
Burst |
The output's B= specification must match the Burst
specification of the printer. Otherwise this output group is not
selected. |
It is not required that the B= specification of
the output group match the Burst specification of the printer. However,
JES2 issues the $HASP190 setup message if a difference exists. |
CReator |
The output group's CReator specification must
match the CReator specification of the printer. Otherwise, this output
group is not considered selectable. |
It is not required that the CReator= specification
of the output group match the CReator= specification of the printer.
However, JES2 issues the $HASP190 setup message if a difference exists. |
{FCB|C} |
The output group's FCB image or carriage control
tape must match the current FCB or carriage control tape of the output
device. Otherwise, this output group is not selected. |
It is not required that the output group match
the FCB or carriage control tape specification of the printer. However,
if differences exist in both the FCB and FORMS specifications, JES2
issues the $HASP190 setup message. |
{FLash|O} |
The output group's FLASH or forms overlay must
match the current FLASH (O=) specification for the output device.
Otherwise the output group is not selected. |
It is not required that the output group match
the FLASH (O=) specification for the printer. However, JES2 issues
the $HASP190 setup message if a difference exists. |
Forms |
The output group's forms specification must match
one of the forms specified for the output device. Otherwise the output
group is not selected. If there are multiple forms, the forms have
equal priority. |
It is not required that the forms of the output
group match the current forms setup of the device. However, JES2
issues the $HASP190 setup message if a difference exists. In this
case it is preferred that the forms of the output group match one
of the forms specified for the device. |
JOBname |
The output group's jobname must match the jobname
specified (JOBNAME=) for this device. |
It is not required that the job name of the output
group match the job name specified (JOBNAME) for this device. JES2
attempts to consecutively select all eligible output for a particular
job. |
LIMit |
The amount of output generated by an output group
must fall within the limits set for this device, otherwise the output
group is not considered selectable. Page limits are checked if the
data set is in page mode. Record limits are checked if the data set
is in line mode. If the page data set contains some line mode data,
then both page limits and record limits are checked. |
It is not required that the amount of output generated
by the output group fall within the limits. This subparameter
has no effect as a work selection value for files received from a
node that does not provide a page count for its files. For more information,
refer to the sending node's reference documentation.
|
{PMD} {PRMode} |
The output group's process mode must match one
of the process modes (PRMODE=) specified for the output device. Otherwise
the output group is not selected. If there are multiple PRMODEs, the
list is considered to be in priority sequence with the highest priority
given to the first PRMODE in the list. |
The process mode of the output group must match
the process mode (PRMODE=) specified for the output device, but if
there are multiple PRMODEs the list is not in priority sequence. |
Priority |
The priority of the output group is to be considered.
Whether specified before or after the slash, higher priority output
groups are preferred. Placement of ‘P' in the WS list gives priority
importance in the work selection process. There is no ‘matching'
done for priority. Note: Output groups are added to the
class queues in priority order, and the class queues are scanned in
the device's class list order. The output groups are not scanned by
priority order across class queues. Thus, if all other work selection
criteria for the output groups are equal, all of the output groups
for the first class in the device's class list are selected in priority
order before the output groups for the second class in the list. This
is the selection order even if higher priority output groups exist
on the class queue for the second class in the device's list.
|
Same as before slash. |
Queue |
When Queue is specified in the WS list, only those
output classes specified for this device are searched for work. Otherwise
all classes (A-Z and 0-9) are searched. It is therefore suggested
that ‘Q' always be included in the WS list. The sequence of the
list is the order of search. |
The output classes specified for this device are
not in priority sequence. All classes are equally preferred. Output
groups in the first class in the list are selected first if they meet
all other requirements. |
RANGE |
The job number of the job associated with the
output group must be within the range (RANGE=) specified for this
device. |
It is not required that the job number of the
job associated with the output group be within the specified range
(RANGE=). |
Routecde |
The output group's destination must match the
route code (R=) specified for this device. Otherwise the output group
is not selected. If there are multiple route codes specified for the
device, the list is considered to be in priority sequence and a match
with the first route code is preferred. |
The destination of the output group must match
the route code (R=) specified for this device, but if there are multiple
route codes the list is not considered to be in priority sequence. |
{UCS|T} |
The output group's universal character set must
match the universal character set (UCS=) specified for this device.
Otherwise the work is not selected. |
It is not required that the universal character
set of the output group match the universal character set specified
for this device. However, JES2 issues the $HASP190 setup message
if a difference exists. |
Volume |
The volume of the job associated with this output
group must match the volume (VOLUME=) specified for this device. If
there are multiple volumes specified, the list is considered to be
in priority sequence with the leftmost volume having the highest priority. |
The volume of the job associated with this output
group must match the volume (VOLUME=) specified for this device but
if there are multiple volumes specified, the list is not considered
to be in priority sequence. |
Writer |
The writer name specified for the output group
must match the writer name specified (W=) for this device, otherwise
the output group is not considered selectable. |
It is not required that the writer name of the
output group match the writer name (W=) specified for the device. |
|