- DISPLEN=n | %varname
- This
attribute is used to specify a length for the variable displayed in
the scrollable field.
When DISPLEN=n is
used, n specifies the initial length of
the variable. n must be a value between
1 and 32 767.
%varname is a
dialog variable that can contain a value between 1 and 32 767
to specify the initial length of the variable displayed in the scrollable
field. After the panel is displayed %varname contains
the maximum of the length of the dialog variable displayed and the
initial length specified. When the scrollable field has been defined
using the LSTCOL tag, the length of the dialog variable displayed
is the maximum of all instances on the current display for that variable.
- INDVAR=ind-var
- This
attribute specifies the name of a dialog variable that contains the
left and right scroll indicator.
ind-var is
a 2-byte scroll indicator dialog variable that is updated with 1-byte
indicators showing whether left and right scrolling can be performed.
- INDVAL='ind-chars'
- This
attribute is used to override the default scroll indicator values
of '-' and '+' where:
- -+
- indicates you can scroll left or right
- -
- indicates you can only scroll left
- +
- indicates you can only scroll right
ind-chars must
be a 2-byte literal enclosed in quotes.
The INDVAL attribute
can only be specified together with the INDVAR attribute.
- LINDVAR=lind-var
- This
attribute specifies the name of a dialog variable that contains the
left scroll indicator.
lind-var is a
1-byte left-scroll-indicator dialog variable that is updated with
an indicator showing whether left scrolling can be performed. The
LINDVAR attribute cannot be defined together with the INDVAR attribute.
- LINDVAL='lind-char'
- This
attribute is used to override the default left-scroll-indicator value
of '-'.
lind-char must be a 1-byte literal
enclosed in quotes.
The LINDVAL attribute can only be specified
together with the LINDVAR attribute.
- RINDVAR=rind-var
- This
attribute specifies the name of a dialog variable that contains the
right scroll indicator.
rind-var is
a 1-byte right-scroll-indicator dialog variable that is updated with
an indicator showing whether right scrolling can be performed. The
RINDVAR attribute cannot be defined together with the INDVAR attribute.
- RINDVAL='rind-char'
- This
attribute is used to override the default right-scroll-indicator value
of '+'.
rind-char must be a 1-byte literal
enclosed in quotes.
The RINDVAL attribute can only be specified
together with the RINDVAR attribute.
- SINDVAR=sind-var
- This
attribute specifies the name of a dialog variable that contains the
separator scroll indicator.
sind-var is
a separator scroll indicator dialog variable that is initialized with
the value repeated for the length of the scrollable field displayed
on the panel. If the field is scrollable to the left, the leftmost
byte is the value of the left indicator (default: '<'). If the
field is scrollable to the right, the rightmost byte is the value
of the right indicator ('>').
- SINDVAL='sind-chars'
- This
attribute is used to override the default separator scroll-indicator
value of '<->'.
sind-chars must
be a 3-byte literal enclosed in quotes.
The SINDVAL attribute
can only be specified together with the SINDVAR attribute.
- LCOLIND=lcol-var
- This
attribute specifies the name of a dialog variable that contains the
value of the left column position for the displayed scrollable field.
lcol-var is a dialog variable that is
updated when the field is scrolled to contain the value of the left
column position. This dialog variable can be used to specify an initial
left column position for the scrollable field.
Note: If the same lcol-var is
specified on multiple SCRFLD tags the associated panel fields scroll
simultaneously. When the same lcol-var is
associated with multiple panel fields, the conversion utility only
defines lcol-var as a left column position
indicator panel field for the first of those panel fields.
- LCOLDISP=NO | YES
- This
attribute is used to specify whether the left column position indicator
defined using the LCOLIND attribute is displayed on the panel.
When
LCOLDISP=NO, the left column indicator is not generated as a panel
field.
- RCOLIND=rcol-var
- This
attribute specifies the name of a dialog variable that contains the
value of the right column position for the displayed scrollable field.
rcol-var is a dialog variable that is
updated when the field is scrolled to contain the value of the right
column position.
Note: If the same rcol-var is
specified on multiple SCRFLD tags the associated panel fields scroll
simultaneously. When the same rcol-var is
associated with multiple panel fields, the conversion utility only
defines rcol-var as a right column position
indicator panel field for the first of those panel fields.
- RCOLDISP=NO | YES
- This
attribute is used to specify whether the right column position indicator
defined using the LCOLIND attribute is displayed on the panel.
When
RCOLDISP=NO, the right column indicator is not generated as a panel
field.
- SCALE=scale-var
- This
attribute specifies the name of a dialog variable that contains the
scale indicator.
scale-var is a dialog
variable that is updated with a scale line reflecting the current
columns being displayed for the scrollable field.
SCROLL=ON |
OFF | NOLR | %varname ![End of change](./deltaend.gif)
- This
attribute is used to specify whether the field is scrollable or not.
When SCROLL=OFF, the field is not scrollable.
When
SCROLL=NOLR, LEFT and RIGHT scrolling of the scrollable field is disabled. ![End of change](./deltaend.gif)
%varname is
used to specify the name of a scroll control dialog variable. This
can be set to a value of ON or OFF to turn scrolling for the field
either on or off.
When SCROLL=NOLR, LEFT and RIGHT scrolling
of the scrollable field is disabled.
- FLDSPOS=BELOW |
ABOVE | SAME
- This
attribute is used to specify where the scroll indicator panel fields
are positioned in relation to the heading text for a table display
field defined using the LSTCOL tag or in relation to the display field
defined using the DTAFLD tag.
With FLDSPOS=BELOW, the conversion
utility defines all scroll indicator panel fields for the scrollable
table display field below the heading text or below the data field
defined by the DTAFLD tag.
With FLDSPOS=SAME, the conversion
utility attempts to define ind-var, lind-var,
and rind-var for the data field on the same
line as the data field. This option is not valid when the SCRFLD tag
is nested within a LSTCOL tag.
With FLDSPOS=ABOVE, the conversion
utility defines all scroll indicator panel fields for the scrollable
table display field above the heading text. This option is not valid
when the SCRFLD tag is nested within a DTAFLD tag.