The parameter descriptions for REQUEST=DELETE_MULT are listed in
alphabetical order. Default values are underlined: - REQUEST=DELETE_MULT
- Use this input parameter to delete multiple entries from the list
structure.
- ,ANSAREA=NO_ANSAREA
- ,ANSAREA=ansarea
- Use this output parameter to specify an answer area to contain
information returned from the request. The format of the answer area
is described by mapping
macro IXLYLAA.
When the request completes, the answer area contains
the number of deleted entries (field LAADELCNT).
If the request
completes prematurely, a restart token (field LAARESTOKEN) or extended
restart token (field LAAEXTRESTOKEN) is returned that may be specified
on a subsequent DELETE_MULT request. (See the RESTOKEN and EXTRESTOKEN
parameter descriptions.)
To Code: Specify the RS-type
name or address (using a register from 2 to 12) of an area (with a
length of ANSLEN) to contain the information related to the request.
- ,ANSLEN=anslen
- Use this input parameter to specify the size of the storage area
specified by ANSAREA.
Check the prologue of the IXLYLAA mapping macro for the minimum
required size of the answer area, or use the length field (LAA_LEN)
in the LAA.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 2-byte field that contains the size, in bytes,
of the answer area.
- ,AUTHCOMP=NO_AUTHCOMP
- ,AUTHCOMP=authcomp
- Use this input parameter to specify a value to be compared to
the list authority value of the list specified by LISTNUM. You must
supply the LISTNUM parameter.
If the comparison does not meet the condition specified by the
AUTHCOMPTYPE parameter (EQUAL or LESSOREQUAL), the request fails.
Note: The AUTHCOMP parameter is valid only for list structures allocated
in a coupling facility with CFLEVEL=1 or higher.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the 16-byte field that contains the list authority
value.
- ,AUTHCOMPTYPE=EQUAL
- ,AUTHCOMPTYPE=LESSOREQUAL
- Use this input parameter to specify how the list authority comparison
is to be performed.
- EQUAL
- The list authority for the list specified by LISTNUM must be equal
to the value specified for AUTHCOMP.
- LESSOREQUAL
- The list authority for the list specified by LISTNUM must be less
than or equal to the value specified for AUTHCOMP.
Note: The AUTHCOMPTYPE parameter is valid only for list structures
allocated in a coupling facility with CFLEVEL=1 or higher.
- ,CONTOKEN=contoken
- Use this input parameter to specify the connect token that was
returned by the IXLCONN service. The connect token uniquely identifies
your connection to the list structure, and must be specified on each
IXLLIST invocation.
The connect token is available in the IXLCONN answer area mapped
by IXLYCONA.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field that contains the connect token.
- ,EXTRESTOKEN=NO_EXTRESTOKEN
- ,EXTRESTOKEN=extrestoken
- Use this input parameter to specify an extended restart token
that can be used to resume processing of a DELETE_MULT request that
completed prematurely. The extended restart token is returned in the
answer area (field LAAEXTRESTOKEN), and should be specified on the
next DELETE_MULT request to resume processing.
If the request
does not complete prematurely, the extended restart token will not
be provided. Note: - Specifying an extended restart token of all zeros causes list
services to treat all of the entries as unprocessed.
- Do not specify an extended restart token other than the one returned
in the answer area or one set to all zeros, because results will be
unpredictable.
Requestors that specify IXLCONN ALLOWAUTO=YES
must use the extended restart token. Requestors that specify or default
to IXLCONN ALLOWAUTO=NO must use the standard restart token (RESTOKEN).
To
Code: Specify the RS-type name or address (using a register from
2 to 12) of a 16-byte field that contains the extended restart token.
- ,KEYCOMP=NO_KEYCOMP
- ,KEYCOMP=keycomp
- Use this input parameter to specify a value to be compared to
the entry key of each list entry in the designated list.
If the list entry that is to be processed does not have an entry
key value that is equal to the specified KEYCOMP value, the entry
is not processed. Processing continues with the next entry.
Note: The KEYCOMP parameter is valid only for list structures allocated
in a coupling facility with CFLEVEL=1 or higher.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the 16-byte field that contains the value to be compared
to the entry key of the designated list entry.
- ,LISTNUM=NO_LISTNUM
- ,LISTNUM=listnum
- Use this input parameter to specify the number of the list on
which the entries to be deleted must reside. Specifying a list number
restricts delete processing to entries that reside on the designated
list.
To Code: Specify the RS-type name or address (using
a register from 2 to 12) of a 4-byte field that contains the number
of the list.
- ,LOCKCOMP=NO_LOCKCOMP
- ,LOCKCOMP=lockcomp
- This parameter has slightly different meanings based on the value
specified for the LOCKOPER parameter. Generally, this input parameter
specifies a connection identifier to be verified as the owner of the
lock specified by LOCKINDEX. This verification is a prerequisite to
the successful completion of the request.
When LOCKCOMP is specified, the completion of the request is conditional
on there being no contention for the lock. If contention exists, the
request will fail.
The connection identifier is available from the IXLCONN answer
area, mapped by IXLYCONA, in field CONACONID.
The effect of LOCKCOMP is based on the LOCKOPER value specified.
See the description under LOCKOPER to see how each request is affected
by this parameter.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 1-byte field that contains the connection identifier.
- ,LOCKINDEX=NO_LOCKINDEX
- ,LOCKINDEX=lockindex
- Use this input parameter to specify the index of the lock to be
operated on as specified by LOCKOPER. The lock indexes begin with
zero.
Note: You cannot code LOCKINDEX with MODE=ASYNCNORESPONSE.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that contains the lock index.
- ,LOCKMODE=COND
- Use this input parameter to specify that the lock operation for
the lock specified by LOCKINDEX be performed conditionally; that is,
only if there is no contention for the lock. If the specified lock
is held by another user, the request will be terminated with no change
to the structure, and return and reason codes describing the termination
are returned to the caller.
- ,LOCKOPER=NOTHELD
- ,LOCKOPER=HELDBY
- Use this input parameter to specify the type of operation to be
performed on the lock specified by LOCKINDEX.
- LOCKOPER=NOTHELD
- The request is performed only if the lock is not held by any connection.
This option also ensures that the lock remains free for the duration
of the request. If another connection holds the lock, your task is
suspended until the lock is released, or your request fails depending
on the LOCKMODE value you specify. See the LOCKMODE description for
how to handle possible lock contention.
- LOCKOPER=HELDBY
- When LOCKCOMP is not specified, the request is performed only
if your connection holds the lock.
- When LOCKCOMP is specified, the request is performed only if the
lock is held by the connection specified by LOCKCOMP.
- ,MF=S
- ,MF=(L,mfctrl)
- ,MF=(L,mfctrl,mfattr)
- ,MF=(L,mfctrl,0D)
- ,MF=(E,mfctrl)
- ,MF=(E,mfctrl,COMPLETE)
- Use MF=S to specify the standard form of the macro, which builds
an inline parameter list and generates the macro invocation to transfer
control to the service.
Use MF=L to specify the list form of the macro. Use the list form
together with the execute form of the macro for applications that
require reentrant code. The list form defines an area of storage that
the execute form uses to store the parameters. Only the PLISTVER parameter
can be coded with the list form of the macro.
Use MF=E to specify the execute form of the macro. Use the execute
form together with the list form of the macro for applications that
require reentrant code. The execute form stores the parameters into
the storage area defined by the list form, and generates the macro
invocation to transfer control to the service.
- ,mfctrl
- Use this output parameter to specify a storage area to contain
the parameters.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the parameter list.
- ,mfattr
- Use this input parameter to specify the name of a 1- to 60-character
string that can contain any value that is valid on an assembler DS
pseudo-op. You can use this parameter to force boundary alignment
of the parameter list. If you do not code mfattr, the system
provides a value of 0D, which forces the parameter list to a doubleword
boundary.
- ,COMPLETE
- Use this input parameter to require that the system check for
required parameters and supply defaults for omitted optional parameters.
Note: In the macro expansion you might see some defaults for optional
parameters that are not documented here. The ones that are not documented
do not have any effect on the macro. For example, if SMILE=var were
an optional parameter and the default is SMILE=NO_SMILE then it would
not be documented. However, if the default was SMILE=:-), then it
would be documented because a value would be the default.
- ,MODE=SYNCSUSPEND
- ,MODE=SYNCECB
- ,MODE=SYNCEXIT
- ,MODE=SYNCTOKEN
- ,MODE=ASYNCECB
- ,MODE=ASYNCEXIT
- ,MODE=ASYNCTOKEN
- ,MODE=ASYNCNORESPONSE
- Use this input parameter to specify:
- Whether the request is to be performed synchronously or asynchronously
- How you wish to be notified of request completion
- MODE=SYNCSUSPEND
- The request is suspended until it can complete synchronously.
To use this option, your program must be enabled for I/O and external
interrupts.
- MODE=SYNCECB
- The request processes synchronously if possible. If the request
processes asynchronously, the ECB specified by REQECB is posted when
the request completes.
- MODE=SYNCEXIT
- The request processes synchronously if possible. If the request
processes asynchronously, your complete exit is given control when
the request completes.
- MODE=SYNCTOKEN
- The request processes synchronously if possible. If the request
processes asynchronously, an asynchronous request token is returned
in the area specified by REQTOKEN on invocation of the request. Use
the returned request token on the IXLFCOMP macro to determine whether
your request has completed.
Note: ANSAREA is a required parameter when MODE=SYNCTOKEN is specified.
- MODE=ASYNCECB
- The request processes asynchronously. The ECB specified by REQECB
is posted when the request completes.
- MODE=ASYNCEXIT
- The request processes asynchronously. Your complete exit is given
control when the request completes.
- MODE=ASYNCTOKEN
- The request processes asynchronously. An asynchronous request
token is returned in the area specified by REQTOKEN upon invocation
of the request. Use the returned request token on the IXLFCOMP macro
to determine whether your request has completed.
Note: ANSAREA is a required parameter when MODE=ASYNCTOKEN is specified.
- MODE=ASYNCNORESPONSE
- The request processes asynchronously. No notification of request
completion is provided. The answer area (ANSAREA) fields will not
contain valid information when this mode is specified.
Note: You cannot code MODE=ASYNCNORESPONSE with LOCKINDEX, BUFFER,
or BUFLIST.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=plistver
- Use this input parameter to specify the version of the macro.
See Understanding IXLLIST Version Support for a description of the
options available with PLISTVER.
- ,REQDATA=NO_REQDATA
- ,REQDATA=reqdata
- Use this input parameter with MODE=SYNCEXIT or MODE=ASYNCEXIT
to pass any data you choose to the complete exit. The exit will get
control only if the request is processed asynchronously.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the data to be passed
to the complete exit.
- ,REQECB=reqecb
- Use this output parameter with either MODE=SYNCECB or MODE=ASYNCECB
to specify the address of an ECB, which is to be posted when the request
completes if the request was processed asynchronously.
Before coding REQECB, you must ensure that:
- You initialize the ECB before you issue the request.
- The ECB resides in either common storage or the home address space
where IXLCONN was issued.
- Any tasks that wait for the ECB to be posted reside in the home
address space where IXLCONN was issued.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that contains the address of the ECB
to be posted when the request completes. The ECB must be aligned on
a fullword boundary.
- ,REQID=NO_REQID
- ,REQID=reqid
- Use this input parameter to specify a user-defined request identifier
to be associated with the request. You can specify this request identifier
on the IXLPURGE macro to cancel a request that has not yet been processed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the user-defined request
identifier.
- ,REQTOKEN=reqtoken
- Use this output parameter with either MODE=SYNCTOKEN or MODE=ASYNCTOKEN
to specify the address of a storage area to receive the request token
that is returned when the request will be processed asynchronously.
This token, which uniquely identifies the request, must be used as
input to the IXLFCOMP macro, which you use to determine if the request
has completed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field where the system will put the request
token.
- ,RESTOKEN=NO_RESTOKEN
- ,RESTOKEN=restoken
- Use this input parameter to specify a restart token that can be
used to resume processing of a DELETE_MULT request that completed
prematurely because it exceeded the coupling facility model-dependent
time-out criteria. The restart token is returned in the answer area
(field LAARESTOKEN), and should be specified on the next DELETE_MULT
request to resume processing with the next entry to be deleted.
If
the request does not exceed the model-dependent time-out criteria,
the returned token will not be provided. Note: - Specifying an extended restart token of all zeros causes list
services to treat all of the entries as unprocessed.
- Do not specify an extended restart token other than the one returned
in the answer area or one set to all zeros, because results will be
unpredictable.
Requestors that specify or default to IXLCONN
ALLOWAUTO=NO must use the standard restart token. Requestors that
specify IXLCONN ALLOWAUTO=YES must use the extended restart token
(EXTRESTOKEN).
To Code: Specify the RS-type name or
address (using a register from 2 to 12) of an 8-byte field that contains
the restart token.
- ,RETCODE=retcode
- Use this output parameter to specify a field to contain the return
code. (The return code is also returned in register 15.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the return code
when the request has completed.
- ,RSNCODE=rsncode
- Use this output parameter to specify a field to contain the reason
code returned, if applicable. (The reason code is also returned in
register 0.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the reason code
(if any) when the request has completed.
- ,VERSCOMP=NO_VERSCOMP
- ,VERSCOMP=verscomp
- Use this input parameter to specify a version number to be compared
to the version number of each entry to be deleted. Only those entries
with a version that meets the condition specified by the VERSCOMPTYPE
parameter will be deleted.
To Code: Specify the RS-type
name or address (using a register from 2 to 12) of an 8-byte field
that contains the version number.
- ,VERSCOMPTYPE=EQUAL
- ,VERSCOMPTYPE=LESSOREQUAL
- Use this input parameter to specify how a list entry version number
comparison as specified by VERSCOMP is to be performed.
Note: The VERSCOMPTYPE parameter is valid only for list structures
allocated in a coupling facility with CFLEVEL=1 or higher.
- VERSCOMPTYPE=EQUAL
- The version number for the list entry must be equal to the value
specified for VERSCOMP.
- VERSCOMPTYPE=LESSOREQUAL
- The version number for the list entry must be less than or equal
to the value specified for VERSCOMP.
|