ERB239I z/OS MVS System Messages, Vol 5 (EDG-GFS) SA38-0672-00 |
|
ERB239I sid: ABEND U1405 FROM ERBPUTSM - INPUT
ERROR ExplanationDuring display session sid, RMF™ module ERBPUTSM was called to add a text string to the logical terminal buffer, but the length specified for the text was zero. System actionIf the error occurred after the session had been successfully initialized, RMF issues message ERB235A to let the operator decide whether or not to continue the session. When RMF cannot issue ERB235A, RMF ends the session. In either case, RMF continues processing all other active sessions. The system writes an ABEND dump for the failing job step. Operator responseIf an installation-supplied reporter module caused the error, notify the responsible programmer. If an IBM-supplied module caused the error, respond to user completion code 1405 and to message ERB235A, if issued. System programmer responseObtain the SYSOUT output for the job. Search problem reporting data bases for a fix for the problem. If no fix exists, report the problem to the IBM® Support Center. SourceResource Measurement Facility™ (RMF) Routing code2 Descriptor code4 |